CA704 CHAUVIN ARNOUX, CA704 Datasheet - Page 2

TESTER, VOLTAGE, CA704

CA704

Manufacturer Part Number
CA704
Description
TESTER, VOLTAGE, CA704
Manufacturer
CHAUVIN ARNOUX
Datasheet

Specifications of CA704

Voltage Measuring Range Ac
2V / 20V / 200V / 690V
Meter Display Type
LCD
Operating Temperature Range
-10°C To +55°C
The
of the electrician. They are adapted for all kinds of measurement situations: terminal switchboards or socket outlets.
Easy to use while wearing gloves, their sharpness and user-friendliness make handling simple and sure.
With each of the testers, just one
hand is needed to easily detect the
phase. For the C.A 704, voltage can
be measured at the same time.
The Safety Multimeter
C.A 751 - C.A 760 - C.A 704
C.A 704
2000-count digital display with
backlighting and HOLD function
Resistance measurements
up to 2 kΩ
Automatic range
Used together, the C.A 751 + the C.A 704
or the C.A 760 tester make quick and
effective standard socket tests (phase
position, connections and voltage).
All automatic
Audible continuity test
Auto
automatic on and off
AC
safety testers are simple and sturdy instruments that correspond to the everyday needs
ALL MEASUREMENTS VERY SIMPLY
/
on 2P+E sockets or terminal strips
DC
, automatic ranges,
C.A 760
The Safety Voltage Tester
8 LEDs from 12 V to 690 V
and 750 V
Circuit breaker trigger test
Phase rotation direction is defined by a TT, TN,
or IT neutral system due to an innovative 2-wire
method. This test operates on generator sets.
DC
• AC and / or DC voltage
• Audible and visual
• Direction of phase rotation
• Phase position
continuity test
AC
Used together, the C.A 751 + C.A 760
create a resistive phase-earth link for
safely testing a 30 mA circuit breaker
at 230 V
With the test probes attached to
the casing, their 19 mm center
distance corresponds to the
pole pitch of circuit breakers.
AC
.
The 2P+E Socket Tester
C.A 751
Ground conductor
and phase position
connection, etc.
Reversible, self-powered
Adapts to the C.A 704
and C.A 760
Can be used alone or with a multimeter
on European format sockets
In voltage measurement, standard D2 test
probes reach to the back of terminal strips.
The C.A 751 socket tester fits perfectly to either
the C.A 704 or the C.A 760 in order to make easy, yet
complete safety European format socket tests. This
socket tester can be used on sockets having the earth
plug either on top or on the bottom.
Self-powered, it can also be used
alone to check socket connections
and phase positions.
The C.A 751 marries ideally with a
multimeter with D4 keys: the 2P+E
adapter terminals are made for test
probes with a diameter of 4 mm.
DIAGNOSIS FOR ELECTRICAL
SOCKET CABLING
Here, the wiring is cor-
rect: the central neon
and one of the two
bottom neons (phase
position) light up.
TECHNICAL SPECIFICATIONS C.A 751
Voltage: 230 V network / frequency: 50/60 Hz
Installation neutral system: TT and TN
Does not trigger the circuit breaker.
European standard and Electrical safety:
IEC 61243-3 in association with a C.A 704 or a C.A 760,
EN 61010-1 category II, assigned voltage 230 V
Electromagnetic compatibility EN 61326-1/A2 criterion B
Protection rating of enclosure according to EN 61010-1: IP 20
Operating use: -10 °C to +55 °C for 96 % RH
Self-powered by the measurement
Dimensions: 95 x 50 x 38 mm / mass: 60 g
Another result: there
is a problem in the
socket's wiring.
Ex.: here, all the neons
light up: thus an earth
fault.