608-H2 TESTO, 608-H2 Datasheet - Page 43

HYGROMETER

608-H2

Manufacturer Part Number
608-H2
Description
HYGROMETER
Manufacturer
TESTO
Datasheet

Specifications of 608-H2

Humidity Range
2% To 98%
Resolution (°c)
0.1°C
External Height
120mm
External Width
89mm
External Depth
40mm
Svhc
No SVHC (15-Dec-2010)
Accuracy %
2%
Battery Size Code
9V
Operating Temperature Max
70°C
Velocity module, incl. volume flow, degree of turbulence...
upgrade via service (updates testo 650 to testo 400)
Rech. batt. set for instr. (2 rech. 2.4V/1100mAh)
selected for quick recharging in instrument
Mains unit 230 V/ 8 V/ 1 A, for instrument (European plug)
for mains operation and battery recharging
Lithium battery, button cell, type CR 2032, Spare Li cell to save RAM data,
when changing battery and rech. battery
Attachable printer (securely attached) including 1 roll of thermal paper and
batteries
Testo fast printer with wireless infrared interface, 1 roll thermal paper and 4
AA batteries
Fast testo 575 printer, incl. 1 roll of thermal paper and batteries
infrared thermal line printer with graphics function
External fast charger for 1-4 AA rech. batteries, incl. 4 Ni-MH rech. batteries
with individual cell charging and charge control display, incl. impulse trickle
charging, integrated discharge function, with built-in international mains
plug, 100-240 V, 300 mA, 50/60 Hz
Spare thermal paper for printer (6 rolls)
Spare thermal paper for printer (6 rolls)
measurement data documentation legible for up to 10 years
Label thermal paper (Testo patent) for testo 575 printer (6 rolls), can be
applied directly
SoftCase (protects instrument from impact) with carrier strap, magnetic
holder and probe holder
SoftCase for attachable printer (protects printer from dirt/impact)
protects from impact and falls
ComSoft 3 - Professional with data management
incl. database, analysis and graphics function, data analysis, trend curve
RS232 cable
connects instrument to PC (1.8 m) for data transfer
Ethernet adapter, RS232 - Ethernet incl. software driver, mains unit
facilitates data communication in network
System case (plastic) for measuring instrument, probes and accessories
probes in lid make it easy to find parts in case (540 x 440 x 130 mm)
System case (aluminium) for measuring instrument, probes and accessories
probes in lid make it easy to find parts in case
testo 650
Accessories
Update from testo 650 to testo 400
Accessories for measuring instrument
Printer and Accessories
SoftCase for instrument and printer
Software and Accessories
System case
Additional information at
Recommended sets and accessories
www.testo.com
www.testo.com
0554 0549
0554 1775
0554 0610
0554 0569
0554 0568
0554 0561
0554 0830
0409 0178
0554 1711
0516 0400
0516 0410
Part no.
0450 4003
0554 0196
0554 1084
0515 0028
0554 0570
0516 0401
0516 0411
ISO calibration certificate/temperature
for air/immersion probes, calibration points -18°C; 0°C; +60°C
ISO calibration certificate/temperature
Meas. instr. with air/immersion probe; cal. points 0°C; +150°C; +300°C
ISO calibration certificate/temperature
meas. instr. with surface probe; calibration points +60°C; +120°C; +180°C
DKD calibration certificate/temperature
meas. instr. with air/immersion probe; calibration points -20°C; 0°C; +60°C
DKD calibration certificate/temperature
contact surface temperature probes; calibration points +100°C; +200°C; +300°C
ISO calibration certificate/humidity
cal. points freely selectable from 5 to 95%RH at +15 to +35°C or at -18 to +80°C
ISO calibration certificate humidity
Calibration points 11.3 %RH and 75.3 %RH at +25°C
ISO calibration certificate dewpoint
two adjustment points -10/-40 °Ctd at 6 bar
ISO calibration certificate/humidity
saturated saline solutions: calibration point 11.3%RH
ISO calibration certificate/humidity
saturated saline solutions, calibration point 75.3%RH
DKD calibration certificate/humidity
electronic hygrometers; calibration points 11.3%RH and 75.3%RH at +25°C
DKD calibration certificate/humidity
cal. points freely selectable from 5 to 95%RH at +25°C or -18°C to +70°C
DKD calibration certificate/humidity
saturated saline solutions; calibration point 11.3%RH
DKD calibration certificate/humidity
saturated saline solutions; calibration point 75.3%RH
ISO calibration certificate/pressure
differential pressure, accuracy > 0.6 (% of full-scale value)
DKD calibration certificate/pressure
differential pressure, accuracy > 0.6 (% of full-scale value)
ISO calibration certificate/pressure
differential pressure, accuracy 0.1 to 0.6 (% of fsv)
DKD calibration certificate/pressure
differential pressure, accuracy 0.1 to 0.6 (% of full-scale value)
ISO calibration certificate/absolute pressure, 5 measurement points
distributed over meas. range absolute pressure, accuracy 0.1 to 0.6 (% of
fsv)
DKD calibration certificate/pressure
absolute pressure, accuracy 0.1 to 0.6 (% of full-scale value)
Calibration Certificates
Calibration certificates/temperature
Calibration certificates/humidity
Calibration certificates/pressure
0520 0006
0520 0136
0520 0013
0520 0083
0520 0206
0520 0216
0520 0213
0520 0283
0520 0225
0520 0025
0520 0215
0520 0125
0520 0212
Part no.
0520 0001
0520 0021
0520 0071
0520 0211
0520 0271
0520 0106
0520 0005
43