SI2493-C-FT Silicon Laboratories Inc, SI2493-C-FT Datasheet - Page 49

no-image

SI2493-C-FT

Manufacturer Part Number
SI2493-C-FT
Description
56 KBPS, V.92 ISOMODEM SYSTEM-SIDE - LEAD-FREE TSSOP 0 TO 7
Manufacturer
Silicon Laboratories Inc
Datasheets

Specifications of SI2493-C-FT

Mfg Application Notes
SI2493/57/34/15/04, Appl Note AN93
Data Format
V.21, V.22, V.23, V.29, V.32, V.34, V.90, V.92, Bell 103, Bell 212A
Baud Rates
56k
Interface
Parallel
Voltage - Supply
3 V ~ 3.6 V
Mounting Type
Surface Mount
Package / Case
24-TSSOP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
SI2493-C-FT
Manufacturer:
Silicon Labs
Quantity:
135
Part Number:
SI2493-C-FTR
Manufacturer:
SIEMENS/西门子
Quantity:
20 000
Company:
Part Number:
SI2493-C-FTR
Quantity:
1 559
Notes:
Command
1. When in autobaud mode, \B0, \B1, and \P1 is not detected automatically. The combination of \B2 and \P3 is detected.
2. When changing rates, the result code “OK” is sent at the old DTE rate. Subsequent commands must be sent at the new
3. The autobaud feature does not detect this rate.
4. Default is \T16 (autobaud); otherwise, \T9 (19.2 kbps) if a pulldown is connected to pin 18 (24-pin device only).
\T15
\T16
\T17
\Vn
\V0
\V2
\V4
\U
This is compatible with seven data bits, no parity, two stop bits. Seven data bits, no parity, one stop bit may be forced by
sending AT\T17\B1.
rate. When the Si2493/57/34/15/04 is configured in autobaud mode, \T0 through \T15 lock the new baud rate and
disable autobaud. To eliminate any possibility of a race condition between the receipt of the result code and the
changing of the UART speed, CTS is de-asserted while the result code is being sent until after the rate has been
successfully changed. The host should send the \T command and wait for the “OK” response. After the “OK” has been
received, the host may send data at the new rate as soon as CTS is asserted. The \T command should be the last
command sent in a multi-command line and may not be used on the same command line as :U or :R commands. If it is
not, the “OK” from the \T command is sent at the old DTE rate, and any other result codes are sent at the new DTE rate.
307.200 kbps
Autobaud On
Autobaud Off. Lock at current baud rate.
Serial mode—causes a low pulse (25 ms) on RI and DCD. INT to be the inverse of ESC. RTS to be
inverse of CTS.
Parallel mode—causes a low pulse (25 ms) on INT.
This command terminates with a RESET and does not generate an “OK” message.
Connect message type.
Report connect and protocol message.
Report connect message only (exclude protocol message).
Report connect and protocol message with both upstream and downstream connect rates.
Table 21. Extended AT\ Command Set (Continued)
4
Rev. 0.9
Action
AN93
49

Related parts for SI2493-C-FT