STLC2416 STMicroelectronics, STLC2416 Datasheet - Page 23

no-image

STLC2416

Manufacturer Part Number
STLC2416
Description
Bluetooth Class I 1.8V 0.721Mbps 120-Pin LFBGA
Manufacturer
STMicroelectronics
Datasheet

Specifications of STLC2416

Package
120LFBGA
Power Class
Class I
Maximum Data Rate
0.721 Mbps
Operating Supply Voltage
1.8 V
Lead Free Status / Rohs Status
Not Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
STLC2416
Manufacturer:
ST
Quantity:
101
Part Number:
STLC2416
Manufacturer:
STMicro
Quantity:
101
Part Number:
STLC2416
Manufacturer:
ST
0
Part Number:
STLC2416MU21CA
Manufacturer:
ST
Quantity:
2 000
Part Number:
STLC2416MU21CA
Manufacturer:
ST
0
Part Number:
STLC2416MU21CAX
Manufacturer:
AMD
Quantity:
3 400
Part Number:
STLC2416MU21CAX
Manufacturer:
ST
Quantity:
12 230
Part Number:
STLC2416MU21CAX
Manufacturer:
ST
0
Figure 12. PCM interface timing
9
The UART Transport Layer has been specified by the Bluetooth™ SIG, and allows HCI level communica-
tion between a host controller (STLC2416) and a host (e.g. PC), via a serial line.
The objective of this HCI UART Transport Layer is to make it possible to use the Bluetooth™ HCI over a
serial interface between two UARTs on the same PCB. The HCI UART Transport Layer assumes that the
UART communication is free from line errors.
9.1 UART Settings
The HCI UART Transport Layer uses the following settings for RS232:
Flow control with RTS/CTS is used to prevent temporary UART buffer overrun. It should not be used for
flow control of HCI, since HCI has its own flow control mechanisms for HCI commands, HCI events and
HCI data.
If CTS is 1, then the Host/Host Controller is allowed to send.
If CTS is 0, then the Host/Host Controller is not allowed to send.
The flow-off response time defines the maximum time from setting RTS low until the byte flow actually
stops. The signals should be connected in a null-modem fashion; i.e. the local TXD should be connected
to the remote RXD and the local RTS should be connected to the remote CTS and vice versa.
Figure 13. UART Transport Layer
– Baud rate:
– Number of data bits:
– Parity bit:
– Stop bit:
– Flow control:
– Flow-off response time:
HCI UART TRANSPORT LAYER
BLUETHOOTH
PCM_B/A out
PCM_SYNC
PCM_A/B in
PCM_CLK
HOST
Configurable (Default baud rate: 57.600 kbps)
8
no parity
1 stop bit
RTS/CTS
3 ms
t
WCH
HCI UART TRANSPORT LAYER
t
WSH
t
BLUETHOOTH HCI
WCL
t
SSC
MSB
MSB
MSB-1
t
SDC
MSB-1
t
DCD
MSB-2
MSB-2
BLUETHOOTH
CONTROLLER
MSB-3
t
HCD
MSB-3
HOST
MSB-4
D02TL557
MSB-4
D02TL556
STLC2416
23/27

Related parts for STLC2416