FNP1800-12G POWER ONE, FNP1800-12G Datasheet - Page 10

Linear & Switching Power Supplies

FNP1800-12G

Manufacturer Part Number
FNP1800-12G
Description
Linear & Switching Power Supplies
Manufacturer
POWER ONE
Datasheet

Specifications of FNP1800-12G

Output Voltage
12/12V
Number Of Outputs
2
Input Frequency
47 to 63Hz
Efficiency
90%
Screening Level
Commercial
Product Length (mm)
279.4mm
Operating Temperature Min Deg. C
0C
Operating Temperature Max Deg. C
70C
Mounting Style
Desktop
Product
Switching
Lead Free Status / RoHS Status
Compliant
Lead Free Status / RoHS Status
Compliant
Paralleling Front-Ends:
For parallel use in minimal configuration systems, only the inhibit pins must be shorted to logic GND. All other pins can be left
open. The power supplies will share the output current automatically (droop current share).
For parallel applications without I
backplane together, to connect all V
The sense wires can be left open or connected to a common load point, the synch-start pin can be left open or connected to a
synch-start circuit, the inhibit pins can be connected together or used individually. All I
open.
Use of a small foil capacitor > 3µF directly at the power outputs of each unit is recommended in order to prevent voltage drops at
the hot plug. For additional information on paralleling see the following Rack (Power Shelf) section.
Racks
(FNR-3-12G and FNR-3-48G Power Shelves)
Each rack (power shelf) is 1U high with backplane and designed for up to three front-end models in parallel or in n+1 operation.
Each power shelf has:
Overall Mechanical Dimensions (FNR-3-12G and FNR-3-48G Power Shelves)
MCD10074 Rev. 1.2, 15-Apr-10
Massive copper bus bars for low-loss current distribution.
Output terminals with two M4-screws on each power tab.
Two fast-on contacts for system earthing.
Address coding over five pole DIP switch on each unit, 37-pin D-Sub connector with I
support functions.
Provides a start-up synchronization circuit and EMV filters.
FNR-3 Mechanical Data (W, H, D)
2
C bus, but the use of all other features, it is recommended to connect all logic GND’s on a
o2
FNR-3-12G and FNR-3-48G Power Shelf Front View
-, all V
o2
+ and to leave the internal GND’s open.
Page 10 of 17
17.7” (449.6 mm) x 1.7” (43.1 mm) x 13” (330.2 mm)
& FNR-3 Power Shelf Data Sheet
FNP1500/1800 Front-Ends
2
C signals (T1-T5, S1, and S2) can be left
2
C-lines, monitoring signals and
www.power-one.com

Related parts for FNP1800-12G