863743-1 TE Connectivity, 863743-1 Datasheet - Page 3

Cable Assembly Lead 0.305m 22AWG 3 POS LGH PL

863743-1

Manufacturer Part Number
863743-1
Description
Cable Assembly Lead 0.305m 22AWG 3 POS LGH PL
Manufacturer
TE Connectivity
Datasheets

Specifications of 863743-1

Connector Type
3POS LGH
Cable Type
Lead
Gender
PL
Cable Length
0.305 m
Rohs Compliant
YES
Housing Material
Silicone Rubber
Contact Material
Copper Alloy
Contact Plating
Gold over Nickel
Insert / Contact Gender
Male
Number Of Positions / Contacts
3
Product Type
Plug Connectors
Wire Gauge Range
22
Wire Size (mm² [awg])
22
Operating Voltage (kvdc)
7.5
Assembly Length (mm [in])
304.80 [12.000]
Number Of Positions
3
Wire Color
Brown
Wire Insulation
Silicon Rubber
Contact Type
Socket
Contact Size
22
Contact Base Material
Copper Alloy
Contact Plating, Mating Area, Material
Gold per MIL-G-45204
Contact Sleeve Material
Stainless Steel
Connector Style
Plug
Rohs/elv Compliance
RoHS compliant, ELV compliant
Lead Free Solder Processes
Not relevant for lead free process
Rohs/elv Compliance History
Always was RoHS compliant
Test Voltage
12 KVDC at 10,000 feet and -15°C to +85°C
Lead Free Status / Rohs Status
 Details
Rev O2
Vibration, sinusoidal.
Mechanical shock.
Durability.
Contact engaging force.
Contact separating force.
Therm al shock.
Hum idity, steady state.
Tem perature life.
Test Description
No discontinuities of 10
m icroseconds or longer duration.
See Note.
No discontinuities of 1 m icrosecond
or longer duration.
See Note.
See Note.
20 ounces m axim um .
3 ounces m inim um .
See Note.
See Note.
See Note.
ENVIRONMENTAL
MECHANICAL
Figure 1 (cont)
Requirem ent
EIA-364-28, Test Condition I.
Subject m ated specim ens to 10-55-
10 Hz traversed in 1 m inute with 1.5
m m [.06 in] m axim um total
excursion. 2 hours in each of 3
m utually perpendicular planes.
EIA-364-27, Method H.
Subject m ated specim ens to 30 G's
half-sine shock pulses of 11
m illiseconds duration. 3 shocks in
each direction applied along 3
m utually perpendicular planes, 18
total shocks.
EIA-364-9.
Mate and unm ate gold plated
specim ens for 500 cycles and tin
plated specim ens for 50 cycles at a
m axim um rate of 500 cycles per
hour.
AMP Spec 109-35.
Measure force necessary to
engage using gage 2 to a depth of
.19 inch for 1/2I and 1/2LI and .25
inch for 1I, 1LI, 2I, 3I and 4I.
See Figure 4.
AMP Spec 109-35.
Size 3 tim es using gage 2. Then
insert gage 1 to depth of .19 inch
for 1/2I and 1/2LI and .25 inch for
1I, 1LI, 2I, 3I and 4I and m easure
force necessary to separate.
See Figure 4.
EIA-364-32.
Subject specim ens to 5 cycles
between -55 and 125 C.
EIA-364-31, Method II, Condition A.
Subject specim ens to 40 C and 90
to 95% RH for 96 hours.
EIA-364-17, Method A, Test
Condition 5, Test Tim e Condition A.
Subject m ated specim ens to 125 C
for 96 hours.
Procedure
108-36033
3 of 6

Related parts for 863743-1