Specifications of TC-14-MQ-70

Accessory Type
Temperature Control
For Use With/related Products
Thermoelectric Assemblies
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Direct-Liquid systems (DL)
Direct-Liquid assemblies are used to cool or heat either objects
attached directly to the cold plate, or enclosures by attaching a
thermal conductive container to the cold plate. Heat is dissipated
to a liquid on the warm side. The liquid circuit is normally of a
recirculating type with a pump and a liquid-to-air heat exchanger
removing the heat into the ambient air. By using an efficient heat
exchanger and one or more DL-assemblies a very powerful yet
compact system is created.
Our standard assemblies are optimized for high cooling capaci-
ty and efficiency rather than maximum ∆T. Typical applications
include temperature cycling of electronic components, laser coo-
ling and analytical instruments.
Product specifications
Part #
DL-060-12-00
DL-120-24-00
DL-210-24-00
Lc
Drawing DA-020 and DA-038
Lw
-V*-
Ex =Example: At ambient 32°C and cooled space
temperature 2°C (∆T = 30°C) the DA-075-24-02
(curve C) cools by 32% of its maximum effect, which
gives P c = 71 x 0.32 = 22.7 (±10%)
4xM5x10
Cooling Power
P c max (W)
122
207
59
Hc
Hw
P c Curve
type
C
C
C
Ww
Wc
Current
(A)
4.2
4.2
8.1
input (W)
Power
101
194
50
max (°C)
Ambient
63
62
62
DIRECT COOLING & HEATING
Weight
(kg)
0.4
0.7
1.3
DA-drawing
DL-drawing
100
140
240
Lw
Lw
Lc
11
120
220
Lc
60
• DL-060
Dimensions (mm)
Ww
Power
60
60
60
Wc
60
60
60
Hw
15
15
15
Hw
Hc
24
24
24
Hc
• DL-210
*= Nominal Voltage (V DC)
Specifications apply to warm side
Liquid temperature 32°C and
nominal Voltage.
Tolerances ±10%
• DL-120
For detailed drawings, please
visit our website
Ww
Wc
M5x8