SRCU41L Intel (CPU), SRCU41L Datasheet - Page 19

no-image

SRCU41L

Manufacturer Part Number
SRCU41L
Description
Manufacturer
Intel (CPU)
Datasheet

Specifications of SRCU41L

Number Of Transceivers
1
Operating Supply Voltage (typ)
5V
Operating Temperature (max)
105C
Operating Temperature (min)
-40C
Operating Temperature Classification
Industrial
Lead Free Status / RoHS Status
Compliant
Fujitsu*
Fujitsu*
Fujitsu*
Fujitsu*
Fujitsu*
Fujitsu*
Fujitsu*
Fujitsu*
Manufacturer
Intel® RAID Controller SRCU41L Tested Hardware and Operating System List
Hard Disk Drives
6.
Enclosure, add-in card, and peripheral testing was performed on the Intel® RAID Controller
SRCU41L by Intel Labs, by independent test labs, or by the vendor. The RAID Controller
SRCU41L compatibility and stress testing is performed with the latest version of an operating
system at the time the validation testing occurred. Although a large sample of configurations
was tested, due to the large number of possible configurations, not all devices were tested
under all operating systems, and not all possible combinations or configurations of third-party
devices were tested for inter-compatibility. Customers should see the Tested Hardware and
Operating System List for the server board to verify that the device is included for the server
board as well as for the RAID Controller SRCU41L.
Add-in adapter card and peripheral compatibility and stress testing will only be performed with
the latest version of an operating system at the time the validation testing occurred. The
following table shows the operating system and base system configurations used to validate
each device. The adapters are divided into categories based on their functionality. All integrated
onboard devices are tested by default and are therefore not included in the following tables.
Note: Not all adapter cards and peripherals were tested under all operating systems.
Any variations to the standard adapter installation process or to expected adapter functionality
are documented in the Installation Guidelines section of this document. If there are installation
guidelines affecting a particular adapter and operating system combination, these are
referenced in the following table. If there are no installation guidelines noted in the following
table, then the adapter installed and functioned as expected using manufacturer’s installation
instructions or Intel’s best-known methods.
Note: Testing of adapters cards normally is performed with unused add-in adapters and
onboard controller expansion ROMs disabled in BIOS Setup. Intel recommends that customers
disable the option ROM for add-in controllers and/or the onboard controllers when not booting
from the controller or needing to use its built-in utilities.
6.1
Note: Hard disk drives are listed ONLY if they were attached to the RAID Controller SRCU41L
during testing.
Revision 3.0
Hard Disk Drives
Hard Disk Drives
Allegro 5
Allegro 7LX
Allegro 7 LE MAN3367MC
Model
Name
MAP3147NC
MAG3182LC
MAM3184MC
MAS3184NC
MAP3367NC
MAS3367NC
MAP3735NC
Model Number
U320
U160/SCA
U160/SCA
U320
U160/SCA
U320
U320
U320
Interface
RPM
10 K
10 K
15 K
15 K
10 K
10 K
15 K
10 K
147 GB
18 GB
18 GB
18 GB
37 GB
37 GB
37 GB
73 GB
Drive
Size
1, 3, 5, 7, 18, 19, 21, 22
1, 3, 6, 9
1, 3, 6, 7, 8, 9, 10
1, 3, 5, 7, 18, 19, 21, 22
1, 3, 6, 7, 8, 9, 10
1, 3, 5, 7, 18, 19, 21, 22, 23, 25, 26,
27, 28
1, 3, 5, 7, 18, 19, 21, 22
1, 3, 5, 7, 18, 19, 21, 22
Tested Operating Systems
19

Related parts for SRCU41L