CH2056A ET Cermetek Microelectronics, CH2056A ET Datasheet

no-image

CH2056A ET

Manufacturer Part Number
CH2056A ET
Description
Manufacturer
Cermetek Microelectronics
Datasheet

Specifications of CH2056A ET

Main Category
Single Chip
Power Supply Type
Analog
Operating Supply Voltage (typ)
3.3/5V
Operating Temp Range
-40C to 85C
Operating Temperature Classification
Industrial
Mounting
Through Hole
Lead Free Status / RoHS Status
Not Compliant
FEATURES
2007 Cermetek Microelectronics, Inc.
Supports V.92, V.90, V.34bis, V.34, V.32bis, V.23,
V.32, V.22bis, V.22A/B, V.23, V.21, Bell 212A and
103.
CH2056A supports V.80 Synchronous operation.
Error correcting: V.42 LAPM, MNP 2-4 and
MNP10. MNP10 Data through put enhancement
for cellular operation.
Data Compression: V.42bis, V.44, and MNP 5
DTE serial interface with speeds up to 230.4kbps
(CH2056A),
(CH1794A).
RoHS Compliant versions available.
Low Power 3.3V operation: 170mW (nominal).
5V operation: 300mW (nominal).
Automatic baud rate adaptability utilizing speed
sensing, flow control and data buffers.
DTMF Encoding and Decoding.
Send & Receive FAX class 1, Group 3 supported.
Serial V.24 interface: 5V tolerant.
NVRAM directory and stored profiles.
AT Command structure, with extensions.
Built-in DAA with 1500 VAC RMS isolation 2122V
peak surge protection.
UL 60950 and CSA C22.2 950 Recognized
(E251266) (pending).
FCC Part 68 approved (pending):
US:B46MM07BCHXXXXAYY.
Industry
(pending):
IC:176A-CHXXXXAY.
PCM upstream (V.92 only).
Modem-on-Hold (V.92 only).
Quick Connect (V.92 only).
Size: 1.01” x 1.27” x 0.52” (nominal).
Pin compatible with low speed CH1786A.
Fast Connect (V.22).
Caller ID (optional).
Zero Power (optional).
Off-Hook Indication (optional).
Leased Line version available.
TBR21 Compliant version available.
Canada
115.2
HIGH SPEED FAMILY OF ULTRA SMALL MODEMS
CH2056A /-B / ET-B
CH1799A /-B / ET-B
CH1794A /-B / ET-B
CS-03
(CH1799A)
Part
I
or
Registered
57.6kbps
Page 1
V.92 / 57,600bps / TBR21
V.34bis / 33,600bps / TBR21
V.32bis / 14,400bps / TBR21
INTRODUCTION
The CH2056A, CH1799A and CH1794A (HS Modem
Family) are industrial grade high-speed modem
modules. Each HS Modem product supports a range
of modem standards and speeds from 300bps to
14,400bps, 28,800bps, 33,600bps or 57,600bps. By
using built in compression algorithms the operation
speed can be expanded to the maximum DTE rate of
57.6kbps for the CH1794A, 115.2kbps for the
CH1799A and 230.4kbps for the CH2056A. A choice
of error correcting schemes is available including MNP
10 for cellular telephone applications. The HS Modem
family supports Send and Receive FAX.
CH179XA-L/CH2056A-L
L/CH2056AR-L operates exclusively on non-voltage
bearing leased line.
The HS Modem family is pin compatible with
Cermetek’s low cost CH1786A V.22bis, 2400bps
modem family. Each module in the HS Modem family
is a self-contained modem and is FCC Part 68
approved (pending) and Industry Canada approved
(pending).
B/ET-B
products meet the European TBR21 requirements.
These ultra small modules are designed for PCB
through-hole mounting and are 1.01” x 1.27” x 0.52”
(nominal) in size. The HS Modem family requires only
two external interfaces: a ITU-T V.24 serial interface
for direct access to a UART, and a Tip and Ring RJ-
11C Jack for the PSTN line connection.
Modem can be controlled with industry standard AT
commands and is compatible with available industry
communication software.
DESCRIPTION
AND DISCUSSION OF BASIC OPERATIONS
Figure 1 contains a functional block drawing of the HS
Modem family of products. Each HS Modem product
consists
modulator/demodulator, modem controller with error
correction and data compression, non-volatile RAM
and a DAA.
Serial Host Interface Buffer. The HS Modem utilizes
a serial V.24 EIA 232-E 5V interface to control the
modem. The HS Modem products can communicate
over the serial interface with the Data Terminal
Equipment (DTE) at a fixed speed regardless of the
carrier line modulation speed (DCE) of the PSTN
modem connection. This eliminates the need to have
and
of
Additionally, the CH179XA/CH2056A-
the
a
OF
Document No. 607-0020 Revision B (01/07)
CH1799AR/CH2056AR-B/ET-B
serial
FUNCTIONAL BLOCKS
and
interface
CH179XAR-
The HS
buffer,
The

Related parts for CH2056A ET

CH2056A ET Summary of contents

Page 1

... Zero Power (optional). • Off-Hook Indication (optional). • Leased Line version available. • TBR21 Compliant version available. 2007 Cermetek Microelectronics, Inc. – V.92 / 57,600bps / TBR21 – V.34bis / 33,600bps / TBR21 – V.32bis / 14,400bps / TBR21 INTRODUCTION The CH2056A, CH1799A and CH1794A (HS Modem Family) are industrial grade high-speed modem modules ...

Page 2

... DAA designed for optimal performance over all PSTN line conditions thereby achieving the most reliable and best performance PSTN connections. 2007 Cermetek Microelectronics, Inc. CH179XA/2056A High Speed Family of Ultra Small Modems The HS Modem family is designed to meet North American telephone standards as set by the FCC Part 68 (USA) and CSA CS-03 Part I (Canada) ...

Page 3

... Result: OK This is identical to the following explicit +MS command: Enter: AT+MS=V22B,0,300,1200,300,1200 Result: OK 2007 Cermetek Microelectronics, Inc. CH179XA/2056A High Speed Family of Ultra Small Modems Refer to and the Figure 2. Example of Off Hook Indication using “H” version HS Modem and external LED and resistor. The minimum transmission rate is not stored and will default to 300bps upon execution of reset or upon power up ...

Page 4

... Cermetek Microelectronics, Inc. CH179XA/2056A High Speed Family of Ultra Small Modems Failure to provide such operating conditions could cause the HS Modem to malfunction or to function erratically ...

Page 5

... T1 during data operation will affect the HS Modem’s output being asserted from another 2007 Cermetek Microelectronics, Inc. CH179XA/2056A High Speed Family of Ultra Small Modems application, use a relay or zero impedance switch to disconnect T1 when in data mode. ...

Page 6

... Note that a 50 msec delay is required between escape characters. These two parameters can be modified via registers S2 and S12, respectively. 2007 Cermetek Microelectronics, Inc. CH179XA/2056A High Speed Family of Ultra Small Modems The HS Modem family of products has been FCC Refer to Part 68 approved as data/FAX modems ...

Page 7

... Refer to the complete list in Table 6. 2007 Cermetek Microelectronics, Inc. CH179XA/2056A High Speed Family of Ultra Small Modems INITIALIZING THE MODEM Before commands may be sent to the HS Modem, the modem must be initialized. This is a two step process: Step 1 ...

Page 8

... Cermetek Microelectronics, Inc. CH179XA/2056A High Speed Family of Ultra Small Modems It should be noted that the default connect result codes 9-20 indicate DTE connection speed, not Carrier Line DCE speed. maximum speed of 19.2kbps (result code 16). The CH1799A will connect at a maximum DTE speed of 38 ...

Page 9

... NOTE: (1) If VCC has a slow power up ramp time, the internal reset may be ineffective. (2) Do not drive LED’s directly from any output. Use Buffers. 2007 Cermetek Microelectronics, Inc. CH179XA/2056A High Speed Family of Ultra Small Modems HS Modem Family Pin Descriptions. FUNCTION Active LOW ...

Page 10

... If the dial command does not specify which type to use, the modem defaults to the type last specified. The power-on default value is T. 2007 Cermetek Microelectronics, Inc. CH179XA/2056A High Speed Family of Ultra Small Modems Example: Pulse dial 9, pause, touch-tone dial number. ...

Page 11

... Caller ID (CID) requires that the PSTN service provider supply the required data. feature will report the NULL string if the CID service is not activated by the PSTN service provider. 2007 Cermetek Microelectronics, Inc. PHONE LINE CONNECTION GUIDELINES 1. The HS Modem must be mounted in the final assembly such that it is isolated from exposure to any hazardous voltages within the assembly ...

Page 12

... Modem can be removed and then forwarded to Cermetek for repair. The following notice is recommended and should be included in the end product’s user manual. 2007 Cermetek Microelectronics, Inc. CH179XA/2056A High Speed Family of Ultra Small Modems FOR YOUR USER’S MANUAL and The Part 68 rules require the following (or equivalent) ...

Page 13

... DTR always active – hang up after transition Long space disconnect disabled Speaker enabled but off when receiving carrier Speaker volume set to low 2007 Cermetek Microelectronics, Inc. CH179XA/2056A High Speed Family of Ultra Small Modems Local modem will not grant RDL request from remote modem Guard tones disabled Minimum DTR pulse width = ...

Page 14

... X 54 +MRR: 19200 +MRR: 21600 +MRR: 24000 +MRR: 26400 +MRR: 28800 CARRIER 16800 CARRIER 21600 CARRIER 24000 CARRIER 26400 CARRIER 28800 +DR: ALT X X 2007 Cermetek Microelectronics, Inc. CH179XA/2056A High Speed Family of Ultra Small Modems Table 4. Notes Result Code Form Terse or Short ...

Page 15

... Xn. A numeral indicates which more explicit message will be output for that X option. 2. Applicable to CH1799A and CH2056A models only. 3. Applicable to CH2056A models only. 2007 Cermetek Microelectronics, Inc. CH179XA/2056A High Speed Family of Ultra Small Modems Notes Command ...

Page 16

... Select modulation +MCR=n Carrier protocol n reporting +MR=n Select extended Reporting of +MCR and +MRR to DTE +MRR=m, n Report Transmit m and Receive n DCE rates to DTE 2007 Cermetek Microelectronics, Inc. CH179XA/2056A High Speed Family of Ultra Small Modems Table 5. Command +PCW +PCM +PIG +PMH up, assumes +PMHF ...

Page 17

... Receive Data with n protocol +FRS=<time> Wait for silence +FTM=n Transmit Data with n protocol Figure 5. Schematic Illustrating Implementation of Voice Injection Feature. 2007 Cermetek Microelectronics, Inc. CH179XA/2056A High Speed Family of Ultra Small Modems Table 5. Function Command +FRH=n +FTH=n +FTS=<time> +FTS=n ...

Page 18

... Factory Default values that are different from the Firmware Default values are highlighted in BOLD. 4. Restore Factory Default values using Zn command. 5. Restore Firmware Default values using &Fn command. 2007 Cermetek Microelectronics, Inc. CH179XA/2056A High Speed Family of Ultra Small Modems Table 6. S-Register Summary. ...

Page 19

... Optional External Over Voltage and Lightning Protection. In most environments, the internal two terminal surge suppressor (see dashed Box 3) is adequate. 2007 Cermetek Microelectronics, Inc. CH179XA/2056A High Speed Family of Ultra Small Modems For severe environments, use an external three terminal device with an earth ground as is shown in dashed Box 3 ...

Page 20

... Input Current (RST Capacitive Load (TXD, DTR, RTS) p Capacitive Load (RST) 1. Output Load = 50 pF ± one TTL. 2. With recommended 30k ohm external resistor. Maximum resistor range: 10k to 100k ohm. 2007 Cermetek Microelectronics, Inc. CH179XA/2056A High Speed Family of Ultra Small Modems Characteristic ...

Page 21

... Inter Character Delay Command Delay 100 Minimum Reset Pulse Duration Note: Must wait for modem response before issuing a new command. Name Type SPK O(DF) PIN NO 2007 Cermetek Microelectronics, Inc. Table 8. HS Modem Electrical Specifications. Typ. Max. Units 20 Ohm 25 dB 250V 100 0.0 +0 ...

Page 22

... Pin placement to outside case edge is nominal ± 0.100 inches. Figure 7B. Physical Dimensions ONLY for the CH179XA-B, CH2056A-B, CH179XA-L, CH2056A-L and CH179XAR-B, CH2056AR-B, CH179XAR-L, CH2056AR-L and extended temperature variations of listed products. 2007 Cermetek Microelectronics, Inc. CH179XA/2056A High Speed Family of Ultra Small Modems Page 22 Document No. 607-0020 Revision B (01/07) ...

Page 23

... Approved, UL 60950 Listed, Industry Canada Registered CS-03 Part I CH1799A-CP Full Function with Caller ID (CID) and Zero Power Down, 33.6kbps, FCC Part 68 Approved, UL 60950 Listed, Industry Canada Registered CS-03 Part I 2007 Cermetek Microelectronics, Inc. CH179XA/2056A High Speed Family of Ultra Small Modems Summary of Features Page 23 Operating Temperature 0° 70°C 0° ...

Page 24

... CH2056A ET-H Full Function with Off-Hook Indication (OHI), 56.0kbps, FCC Part 68 Approved, UL 60950 Listed, Industry Canada Registered CS-03 Part I CH2056A ET-P Full Function with Zero Power Down, 56.0kbps, FCC Part 68 Approved, UL 60950 Listed CH2056A ET-CP Full Function with Caller ID (CID) and Zero Power Down, 56.0kbps, FCC Part 68 Approved, UL 60950 Listed  ...

Page 25

... Part I CH1799AR-CP Full Function with Caller ID (CID) and Zero Power Down, 33.6kbps, FCC Part 68 Approved, UL 60950 Listed, Industry Canada Registered CS-03 Part I 2007 Cermetek Microelectronics, Inc. CH179XA/2056A High Speed Family of Ultra Small Modems Page 25 Document No. 607-0020 Revision B (01/07) Operating Temperature 0° 70°C 0° ...

Page 26

... Full Function with Zero Power Down, 56.0kbps, FCC Part 68 Approved, UL 60950 Listed CH2056AR ET-CP Full Function with Caller ID (CID) and Zero Power Down, 56.0kbps, FCC Part 68 Approved, UL 60950 Listed 2007 Cermetek Microelectronics, Inc. CH179XA/2056A High Speed Family of Ultra Small Modems Summary of Features Page 26 Operating Temperature -40° ...

Page 27

... Therefore, for FCC and IC Approved or Approvable devices, the user assumes all risk for maintaining compliance to registration. 1390 BORREGAS AVENUE | SUNNYVALE CA 94089 CERMETEK WEB SITE: 2007 Cermetek Microelectronics, Inc. CH179XA/2056A High Speed Family of Ultra Small Modems Table 11A and 11B Notes: | LOCAL: 408-752-5000 | TOLL FREE: 1-800-882-6271 http://www ...

Related keywords