MC34911G5ACR2 Freescale, MC34911G5ACR2 Datasheet - Page 12

MC34911G5ACR2

Manufacturer Part Number
MC34911G5ACR2
Description
Manufacturer
Freescale
Datasheet

Specifications of MC34911G5ACR2

Turn Off Delay Time
10us
Number Of Drivers
2
Operating Temperature (min)
-40C
Lead Free Status / RoHS Status
Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MC34911G5ACR2
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
Table 4. Static Electrical Characteristics (continued)
34911, unless otherwise noted. Typical values noted reflect the approximate parameter mean at T
conditions, unless otherwise noted.
12
33911
HIGH SIDE OUTPUT HS1 PIN (HS1)
LOW SIDE OUTPUTS LS1 AND LS2 PINS (LS1, LS2)
ELECTRICAL CHARACTERISTICS
STATIC ELECTRICAL CHARACTERISTICS
Output Drain-to-Source On Resistance
Output Current Limitation
Open Load Current Detection
Leakage Current
Short-circuit Detection Threshold
Over-temperature Shutdown
Over-temperature Shutdown Hysteresis
Output Drain-to-Source On Resistance
Output Current Limitation
Open Load Current Detection
Leakage Current
Active Output Energy Clamp
Short-circuit Detection Threshold
Over-temperature Shutdown
Over-temperature Shutdown Hysteresis
Notes
23.
24.
25.
26.
27.
28.
29.
30.
31.
Characteristics noted under conditions 5.5 V ≤ V
T
T
T
0 V < V
-0.2 V < V
5.5 V < V
T
T
T
2.0 V < V
-0.2 V < V
I
5.5 V < V
OUT
J
J
J
J
J
J
= 25°C, I
= 150°C, I
= 150°C, I
= 25°C, I
= 125°C, I
= 125°C, I
This parameter is production tested up to T
When over-current occurs, the corresponding high side stays ON with limited current capability and the HS1CL flag is set in the HSSR
When open load occurs, the flag (HS1OP) is set in the HSSR
HS and LS automatically shutdown if HSOT or LSOT occurs or if the HVSE flag is enabled and an over-voltage occurs.
When over-temperature shutdown occurs, the high side is turned off. All flags in HSSR are set.
When over-current occurs, the corresponding low side stays ON with limited current capability and the LSxCL flag is set in the LSSR
When open load occurs, the flag (LSxOP) is set in the LSSR.
When over-temperature shutdown occurs, both low sides are turned off. All flags in LSSR are set.
Guaranteed by characterization but not production tested
= 150 mA
OUT
SUP
OUT
SUP
HS1
OUT
LOAD
LOAD
< V
LOAD
LOAD
LOAD
LOAD
< 27 V
< V
< 27 V
< V
< VS1
SUP
= 50 mA; V
= 150 mA, V
SUP
S2
= 50 mA; V
= 30 mA; 5.5 V < V
= 150 mA, V
= 120 mA, 5.5 V < V
- 2.0 V
+ 0.2 V
(24)
(28)
Characteristic
(27),
(30),
(25)
(29)
SUP
(31)
(31)
SUP
(26)
SUP
(26)
SUP
> 9.0 V
> 9.0 V
> 9.0 V
> 9.0 V
(31)
(31)
SUP
SUP
(23)
< 9.0 V
< 9.0 V
A
= 125°C, and guaranteed by process monitoring up to T
(23)
SUP
≤ 18 V, -40°C ≤ T
.
T
T
Symbol
R
HSSD_HYS
R
LSSD_HYS
V
I
I
I
V
T
I
V
LIMHS1
T
LIMLSX
OLHS1
I
OLLSX
I
DS(ON)
DS(ON)
CLAMP
LEAK
LEAK
THSC
HSSD
THSC
A
LSSD
≤ 125°C for the 33911 and -40°C ≤ T
V
V
SUP
SUP
Min
140
160
140
2.0
60
+2.0
-2.0
Analog Integrated Circuit Device Data
J
Typ
160
275
160
5.0
7.5
90
10
10
A
= 150°C.
= 25°C under nominal
Freescale Semiconductor
V
SUP
Max
250
180
350
180
7.0
7.5
2.5
4.5
10
14
10
10
12
10
A
+5.0
≤ 85°C for the
Unit
mA
mA
mA
mA
µA
µA
°C
°C
°C
°C
Ω
Ω
V
V
V
.
.