3B17-02 Analog Devices Inc, 3B17-02 Datasheet - Page 4

no-image

3B17-02

Manufacturer Part Number
3B17-02
Description
Manufacturer
Analog Devices Inc
Datasheet

Specifications of 3B17-02

Lead Free Status / RoHS Status
Not Compliant
1
2
3
4
5
6
voltage output is used, loop power is not required.
7
current.
Specifications subject to change without notice.
For a 0 mA to 20 mA range, a typical minimum output current is 10 µA.
Includes the combined effects of repeatability, hysteresis, and nonlinearity.
With respect to the voltage output.
A wide range of custom zero suppression and span is available with the 3B17-00 model, using the AC1310 ranging card.
Bandwidth can be set for up to 1/10 the excitation frequency when ordering Model 3B17-custom.
+24 V dc loop power is required for driving the current output at loads up to 850
Typical supply current is ±40 mA per module plus ±5 mA for the LVDT drive current. To calculate supply current requirements from LVDT currents, use 75% of the LVDT rms
Voltage
Voltage, tolerance
Frequency
Drive
Harmonic Distortion
Span Adjustment Range
Zero Adjustment Range
Zero and Span Adjustment Range
Input Bias Current
Input Resistance
Bandwidth
Output Rise Time, 10% to 90% Span
Continuous
Transient
Voltage Output Protection
Current Output Protection
±15 V dc Supplies
+24 V dc Loop Supply
Mechanical Dimensions
Temperature Range
Relative Humidity, 24 hours
RFI Susceptibility
Rated Operation
Current
Sensitivity
Rated Operation
Current
Sensitivity
Rated Performance
Storage
5
, -3 dB
Input Protection, Signal and Excitation Voltage
Current Output Calibration
Voltage Output Calibration
1 V rms to 5 V rms
±10%
1 kHz to 10 kHz, ±15%
20 mA rms, minimum
< 0.5%
256:1
±5 V
±5% of Span
+1 µA
100 MΩ
100 Hz
5 ms
130 V rms maximum
ANSI/IEEE C37.90.1-1989
Continuous Short to Ground
130 V rms, continuous
±(13 V dc to 18 V dc)
±65 mA plus LVDT Current
±0.03% span/V
+13.5 V dc to +30 V dc
+27 mA @ l
±0.001% span/V
3.15" x 3.395" x 0.775"
80.0 mm x 86.2 mm x 19.7 mm)
-25°C to +85°C
-55°C to +85°C
0 to 95% @ +60°C non-condensing
±0.5% Span error @ 400 MHz, 5 Watt, 3 ft
Rev. 0 | Page 4 of 8
Environmental
. If a current output load of 400
out
= 20 mA
4
4
7
or less is applied, +15 V dc is sufficient for loop power. If only
3B17

Related parts for 3B17-02