12
Purge Times
The time required to purge a Zeus SSD depends on the actual purge option invoked by the user and
the flash controller/flash memory configuration of the drive. A list of approximate purge times is listed
in Table 3, with the value expressed in seconds per 32 Gigabytes (s/32GB) for each purge option.
Repairs
A defective SSD should be replaced. There are no parts, assemblies or subassemblies that can be
repaired individually by the user. Please see the section titled
inside of the back cover page. Unauthorized repairs to the SSD will void the warranty.
Preventative Maintenance
No preventative maintenance is required. The drive is sealed at the factory, and there are no parts,
assemblies or subassemblies that require preventive maintenance on behalf of the user. Please see
the section titled
maintenance to the SSD will void the warranty.
Hot Plugging Drive
The SSD can be inserted or removed during operation. This capability is known as “hot plugging”.
The error recovery procedures will recover from any errors introduced by hot plugging. The method
used by the system to detect the insertion/removal of the SSD is dependent upon the scenario. For
example, the backplane may be powered, but the SSD may be in a “quiescent” state. It is
recommended that the user reference the Serial ATA 2.6 Specification (SerialATA International
Organization (SATA-IO), High-Speed Serialized ATA Attachment, February 2007) for an overview of
the terms and scenarios associated with “hot plugging” serial drives.
1
2
Hot plugging under the SATA 2.0 standard is limited to backplane applications
and connections; the SSD cannot be connected/disconnected for cabled
applications.
The user should avoid hot plugging a SSD that has been configured as a boot
drive. Unrecoverable errors may be introduced by the operating system if the
user attempts to remove/install a SSD with an OS installed on it.
Certification and Warranty
Purge Option
BasicPurge
RapidPurge
MilPurge
Intelligent Destructive Purge
Table 3.
on the inside of the back cover page. Unauthorized
Purge Times
Value
Zeus 2.5-Inch Serial ATA Solid State Drive
1,200
360
9
2
Certification and Warranty
Units
s/32GB
s/32GB
s/32GB
s/32GB
on the