TFDU6108-TR3 19 Vishay, TFDU6108-TR3 19 Datasheet - Page 19

no-image

TFDU6108-TR3 19

Manufacturer Part Number
TFDU6108-TR3 19
Description
Manufacturer
Vishay
Type
TX/RXr
Datasheet

Specifications of TFDU6108-TR3 19

Peak Wavelength
900nm
Angle Of Half Sensitivity
48°
Pulse Width
2us
Radiant Intensity
0.0003W/sr
Led Supply Voltage
-0.5 to 6V
Package Type
SMD
Fall Time
40ns
Rise Time
40ns
Dimensions
9.7x4.7x4
Operating Supply Voltage (typ)
3.3/5V
Operating Supply Voltage (min)
2.7V
Operating Supply Voltage (max)
5.5V
Mounting
Surface Mount
Pin Count
8
Operating Temp Range
-25C to 85C
Operating Temperature Classification
Commercial
Data Rate
3.90625Mbps
Lead Free Status / RoHS Status
Compliant
The bits shown are placed on the TX (DATA) line and
clocked into the transceiver using the rising edge of
the SCLK signal. Only the data bits are shown as it is
assumed that a clock is always present, and that the
transceiver samples the data on the rising edge of
each clock pulse.
Note: as illustrated in the diagram above, the protocol
uses "Little Endian" ordering of bits, so that the LSB is
sent first, and the MSB is sent last for register
addresses, transceiver addresses, and read/write
data bytes. The notation that follows presents all
addresses and data in LSB-to-MSB order (bits 0, 1, 2,
3, ... 7) unless otherwise stated.
Two-byte Write Commands
Two-byte write commands are used for setting the
contents of transceiver registers which control trans-
ceiver such as shutdown/enable, receiver mode, LED
power level, etc.
The register space requires four register address bits
(R0-3), although three codes are used for controlling
transceiver (see above), and the 1111 escape code is
for extended commands. The 3-bit transceiver
address (A0-3) is for selecting the destination, e.g.
010 to TFDU8108 and 001 to TFDU6108.
The second byte is data field (D0-7) for setting the
characteristics of the transceiver module, e.g. SIR
mode (00) or VFIR (05) when the register address is
0001.
Document Number 82537
Rev. 1.7, 13-May-05
(Set all registers to default value)
Command
RESET
Module Type
TFDU6108
TFDU8108
One-byte Special Commands
One-byte special commands are used for time-critical
transceiver commands, such as full transceiver reset.
A total of six special commands are possible,
although only one command is available on the
TFDU8108 and TFDU6108.
The basic two-byte write command is illustrated
below:
18499
Programming Sequence
18498
0
Sync
Bits
0
Sync
Bits
011 1011 100 00
011 1011 010 00
1
1
Write
(Binary)
1 R0 R1 R2 R3 A0 A1 A2
Write
1
Register
Address
R0 R1 R2 R3
Command
Special
Code
Vishay Semiconductors
Transceiver
Address
A0
Transceiver
Programming Sequence
Address
TFDU6108
A1
1 D0..D7
8-Data
A2
Bits
(Hex)
3B
5B
0
www.vishay.com
Stop
Bits
0
Stop
Bits
0
0
19

Related parts for TFDU6108-TR3 19