TLE6228GPNT Infineon Technologies, TLE6228GPNT Datasheet
TLE6228GPNT
Specifications of TLE6228GPNT
Related parts for TLE6228GPNT
TLE6228GPNT Summary of contents
Page 1
... Robotic Controls General description Quad channel Low-Side-Switch (2x5A/2x3A) in Smart Power Technology (SPT) with four separate in puts and four open drain DMOS output stages. The TLE 6228 GP is fully protected by embedded pro tection functions and designed for automotive and industrial applications. Each channel has its own status signal for diagnostic feedback ...
Page 2
VS STBY ENA IN1 ST1 IN4 ST4 IN2 ST2 IN3 ST3 V4.1 Detailed Block Diagram internal supply Overtemperature Overtemperature Channel 4 Channel 1 Open Load Overload LOGIC Open Load Overload LOGIC Overtemperature Overtemperature Channel 3 Channel 2 Open Load Overload ...
Page 3
Pin Description Pin Symbol 1 GND 2 OUT1 3 ST1 4 IN4 STBY 7 IN3 8 ST2 9 OUT2 10 GND 11 GND 12 OUT3 13 ST3 14 IN2 15 GND 16 ENA Enable Input for all ...
Page 4
... Operating temperature range Storage temperature range Output current per channel (see page 6) Status output current Inductive load switch off energy (single pulse) Electrostatic Discharge Voltage (human body model) according to MIL STD 883D, method 3015.7 and EOS/ESD assn. standard S5.1 - 1993 DIN Humidity Category, DIN 40 040 ...
Page 5
... Output turn off time 4 Output on fall time 4 Output off rise time Overload switch-off delay time 4 Output off status delay time Failure extension Time for Status Report Input Suppression Time Open Load (off) filtering Time 3. Digital Inputs (IN1, IN2, IN3, IN4, ENA) ...
Page 6
Electrical Characteristics Parameter and Conditions – 40 ° 150 ° (unless otherwise specified) 5. Standby Input (STBY) Input low voltage Input high voltage Input current 6. Diagnostic ...
Page 7
... It remains off until the control th signal at the input is switched off and on again. Fault Detection The status outputs indicate the switching state of the output stage. Under normal conditions is low Output off high Output on error occurs, the logic level of the status output is inverted, as listed in the diagnostic table. ...
Page 8
... If current overload or overtemperature occurs for a longer time than t into an internal register and the output is shutdown. The reset is done by switching off the corresponding control input for a time longer than t Open load is detected for all four channels in on and off mode. In the on mode the load current is monitored drops below the specified threshold value IQU then an open load condition is detected ...
Page 9
... Note 1) : Standby is not designed for switching or PWM operation of the outputs Note 2) : overload/short-to-supply/overtemperature - events shorter than min. time t will not be latched and not reported at the status pin. Note reset latched status-output in case of overload/short-to-supply/overtemperature the control input has to go low and stay low for longer than max. input suppression time t ...
Page 10
... Output Slope INL 85% 15 Overload Switch OFF Delay D(lim) I D(OL D-failure V4 Timing Diagrams t off Page Fig Fig. 2 2010-07-10 ...
Page 11
Test Circuit V4 TLE 6228 GP Page 11 2010-07-10 ...
Page 12
Application Circuit V4 Page 12 2010-07-10 ...
Page 13
The blocking capacitor C is recommended to avoid critical negative voltage spikes case of bat tery interruption during OFF-commutation. Timing Diagrams of Diagnostic with Pulsed Input Signal Normal condition, resistive load, pulsed input signal ...
Page 14
Diagnostic status output at different open load current conditions D-failure leads to a static status signal INOFF ...
Page 15
Normal operation, followed by open load condition 12V D-failure D(OL D-failure ...
Page 16
Typical electrical Characteristics Drain-Source on-resistance 9,5V DS(ON Typical Drain- Source ON-Resistance 0,45 0,4 0,35 0,3 0,25 0,2 0,15 -50 -25 0 Typical ON Resistance versus Junction-Temperature Figure 6 : Channel ...
Page 17
Package PG - DSO - all dimensions in mm PIN KIN G A Green Product (RoHS compliant) To meet the world-wide customer requirements for environmentally friendly products and to be ...
Page 18
Revision History Version Date Changes V3.2 V4.0: 2007-06-06: Version Change to Green Product V4.0 2007-06-06 Revision history implemented V4.0 2007-06-06 IFX Logo updated V4.0 2007-06-06 Package name according green nomenclature changed from P-DSO-20-12 to PG-DSO-20-37 V4.0 2007-06-06 Ordering Code removed ...
Page 19
... With respect to any examples or hints given herein, any typical values stated herein and/or any information regard ing the application of the device, Infineon Technologies hereby disclaims any and all warranties and liabilities of any kind, including without limitation, warranties of non-infringement of intellectual property rights of any third party. ...