HIH-5031-001S Honeywell, HIH-5031-001S Datasheet - Page 4

no-image

HIH-5031-001S

Manufacturer Part Number
HIH-5031-001S
Description
Board Mount Humidity Sensors HyCal Sensing Produc 3600 Series CMOS Sen
Manufacturer
Honeywell
Datasheets

Specifications of HIH-5031-001S

Rh Range
0 % to 100 %
Rh Accuracy
+/- 3 %
Output Type
Analog
Supply Voltage (max)
5.5 V
Supply Voltage (min)
2.7 V
Supply Current
200 uA
Maximum Operating Temperature
+ 85 C
Minimum Operating Temperature
- 40 C
Mounting Style
SMD/SMT
Body Style
Rectangular
Current, Switching
500 μA
Function
Humidity
Mounting Type
Surface Mount
Primary Type
Humidity
Range, Measurement
0 to 100 % RH
Voltage, Supply
2.7 to 5.5 VDC
Lead Free Status / RoHS Status
Supplier Unconfirmed
Figure 3. Typical Output Voltage vs Relative Humidity (At 25 °C and 3.3 Vdc.)
Figure 4. Typical Output Voltage (BFSL) vs Relative Humidity (At 0 C, 70 C and 3.3 Vdc.)
4
www.honeywell.com/sensing
2.5
1.5
0.5
2.5
1.5
0.5
3
2
1
3
2
1
0
0
20
20
Relative Humidity (%RH)
Relative Humidity (%RH)
40
40
60
60
80
80
100
100
Rising RH
Falling RH
70° C
0° C