APMS-10GRCF-18 Honeywell, APMS-10GRCF-18 Datasheet

no-image

APMS-10GRCF-18

Manufacturer Part Number
APMS-10GRCF-18
Description
Manufacturer
Honeywell
Datasheet

Specifications of APMS-10GRCF-18

Lead Free Status / RoHS Status
RoHS Not Applicable
Installation Instructions for the
APMS-10G Series
Wash Process Sensor
GENERAL SPECIFICATIONS
Parameter
Supply Voltage
Supply Current
Output Voltage
Storage Temperature
* Assumes a sinking output current of 3 mA maximum.
TURBIDITY SPECIFICATIONS
Characteristic
Range
Ratio Range
Response Time
CONDUCTIVITY SPECIFICATIONS
Characteristic
Range
Range
Response Time
TEMPERATURE SPECIFICATIONS
Characteristic
Range
Accuracy
Response Time
Stabilization Time
MATING CONNECTOR
(2.54/.100 pitch, 3-pin).
MOUNTING
minimum length. Surface finish on mating sealing surface is not to
exceed 32 microinches. The AS-568A-02A O-ring seal is provided
assembled to the sensor.
Sensing and Control
Molex 70400, 70430, or 70066 (G Version) type or equivalent
Mounting holes accept #4 self-tapping screws, 6.4 mm/.250 inch
Sensor Transmit Low
Sensor Transmit High
Sensor Receive Low
Sensor Receive High
Min.
8
0
4
0
3.3
-20
Min.
0
0.03
Min.
.00010
4
Min.
68
-4
3
5
Typ.
24
16
Typ.
Typ.
Typ.
Max.
30
40
1.1
5.25
1.7
5.25
+70
Max.
4000
10
1.3
Max.
15
255
0.85
Max.
140
+4
.03
5
Units
volts
mA
volts*
volts*
volts*
volts*
Units
NTU
units
seconds
Units
mSiemen
units
seconds
Units
second
minutes
C
F
F
CONNECTION DIAGRAM
APMS-10G Series sensors do
not have reverse voltage
protection. Permanent damage
may occur if the sensors are
powered with reverse polarity.
The back of the sensor is not
environmentally sealed.
Permanent damage may occur if
fluids enter through the
connector area. Do not
submerge or wash down the
connector area of the sensor.
The sensor’s optical face should
be kept wet at all times in the
application. Repeated wet/dry
cycles may cause filming from
detergents and mineral deposits.
The sensor contains Class 1
static-sensitive components.
Avoide making contact with the
connector terminals without static
protection.
PK 80023
Vcc
ISSUE 2
I/O
GND

Related parts for APMS-10GRCF-18

APMS-10GRCF-18 Summary of contents

Page 1

... ISSUE 2 PK 80023 CONNECTION DIAGRAM Vcc I/O GND APMS-10G Series sensors do not have reverse voltage protection. Permanent damage may occur if the sensors are powered with reverse polarity. The back of the sensor is not environmentally sealed. Permanent damage may occur if fluids enter through the connector area ...

Page 2

... A .09 Section A-A APMS-10G SERIES DESCRIPTION Catalog Listing Sensor Flow-through Included Cap Installed APMS-10GRCF Yes No APMS-10GRCF-50 Yes .50 in. OD APMS-10GRCF-18 Yes APMS-10GRCF-KIT Yes Both, not installed 2 Honeywell Sensing and Control Issue 2 PK 80023 TURBIDITY CHARACTERISTICS 10 9 7,6 MIN. 8 .30 5,1 7 ...

Page 3

... APMS-10G Series MOUNTING DIMENSIONS (for reference only) CONDUCTIVITY AS-568A-024 O-RING 3,8 .15 45,5 1. 3,2 .13 41,9 1.65 CAP FOR APMS-10GRCF-18 17,9 ø .71 69,9 2.75 For application help: call 1-800-537-6945 39,4 1.55 9,1 .36 8,9 .36 PINS 7,8 . 1,6 .08 15,2 .60 2,5 .10 ø 32 1.26 Vcc O/I ø 35,1 GND 1 ...

Page 4

... APMS-10G Series WARRANTY/REMEDY Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Contact your local sales office for warranty information. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace without charge those items it finds defective. The foregoing is Buyer’ ...

Related keywords