M38510/34901BCA E2V, M38510/34901BCA Datasheet - Page 5

no-image

M38510/34901BCA

Manufacturer Part Number
M38510/34901BCA
Description
Manufacturer
E2V
Datasheet

Specifications of M38510/34901BCA

Lead Free Status / RoHS Status
Supplier Unconfirmed
MIL-PRF-38535 and herein for groups A, B, C, and D inspections (see 4.4.1 through 4.4.4).
follows:
follows:
electrical parameters shall be as specified in table II herein.
are conventional and positive when flowing into the referenced terminal.
4.3 Qualification inspection. Qualification inspection shall be in accordance with MIL-PRF-38535.
4.4 Technology Conformance inspection (TCI). Technology conformance inspection shall be in accordance with
4.4.1 Group A inspection. Group A inspection shall be in accordance with table III of MIL-PRF-38535 and as
4.4.2 Group B inspection. Group B inspection shall be in accordance with table II of MIL-PRF-38535.
4.4.3 Group C inspection. Group C inspection shall be in accordance with table IV of MIL-PRF-38535 and as
4.4.4 Group D inspection. Group D inspection shall be in accordance with table V of MIL-PRF-38535. End-point
4.5 Methods of inspection. Methods of inspection shall be specified as follows:
4.5.1 Voltage and current. All voltages given are referenced to the microcircuit ground terminal. Currents given
a. Tests shall be as specified in table II herein.
b. Subgroups 4, 5, and 6 shall be omitted.
a. End-point electrical parameters shall be as specified in table II herein.
b. The steady-state life test duration, test condition, and test temperature, or approved alternatives shall be
as specified in the device manufacturer's QM plan in accordance with MIL-PRF-38535. The burn-in test
circuit shall be maintained under document control by the device manufacturer's Technology Review
Board (TRB) in accordance with MIL-PRF-38535 and shall be made available to the acquiring or
preparing activity upon request. The test circuit shall specify the inputs, outputs, biases, and power
dissipation, as applicable, in accordance with the intent specified in test method 1005 of MIL-STD-883.
*PDA applies to subgroup 1.
Interim electrical parameters
Final electrical test parameters
Group A test requirements
Group B electrical test parameters
Group C end-point electrical parameters
Group D end-point electrical parameters
when using the method 5005 QCI option
test requirements
MIL-PRF-38535
TABLE II. Electrical test requirements.
MIL-M-38510/349B
5
1*, 2, 3, 7,
8, 9, 10, 11
1, 2, 3, 7, 8,
9, 10, 11
1, 2, 3,
9, 10, 11
1, 2, 3,
9, 10, 11
1, 2, 3
Class S
devices
1
Subgroups (see table III)
1*, 2, 3, 7, 9
1, 2, 3, 7, 8,
9, 10, 11
1, 2, 3
1, 2, 3
N/A
1
Class B
devices