F1400AA06 Curtis Industries, F1400AA06 Datasheet

FILTER HI PERFORM 6A FASTON

F1400AA06

Manufacturer Part Number
F1400AA06
Description
FILTER HI PERFORM 6A FASTON
Manufacturer
Curtis Industries
Series
F1400r
Type
Filterr
Datasheets

Specifications of F1400AA06

Filter Type
Power Line
Voltage - Rated
250V
Current
6A
Mounting Type
Chassis Mount
Termination Style
Fast-On
Application
For industrial or office equipment, computers placed in harsh environments
Brand/series
F1400 Series
Current, Leakage
0.25/0.45 mA
Current, Rating
6 A
Dimensions
38.2mmH×50.8mmW×84.1mmL
Frequency, Operating
50/60 Hz
Hipot Rating, Line To Ground
1500
Hipot Rating, Line To Line
1768
Phase
1
Primary Type
AC
Standards
UL Recognized, CSA Certified, VDE Approved
Temperature, Operating
40 °C
Voltage, Operating
250 VAC
Voltage, Rating
250 VAC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Inductance
-
Other names
364-1087
16
F1400 RFI Filters
Features:
• High Peak Current Design — High Insertion Loss for
• Low-Leakage Current
• Compact Case Sizes in 6 and 10Amp Models
• Available with Integral IEC Connector in 3 and 6Amp
F1400 Simplified Schematic
NOTE: Other combinations of terminals may be specified on special order.
www.curtisind.com
Switching Power Supply Emissions
Models
Nominal
Current
10A
Rating
G
N
L
3A
6A
F1400AA03
F1400BB03
F1400CA03
F1400AA06
F1400BB06
F1400CA06
F1400AA10
F1400BB10
Number
Part
Termination
Line/Load
Wire/Wire
Wire/Wire
Wire/Wire
IEC/QC
IEC/QC
QC/QC
QC/QC
QC/QC
MODE
Common
Differential
Common
Differential
Common
Differential
Curtis Industries
N
L
A Division of Powers Holdings, Inc.
MINIMUM INSERTION LOSS - dB (50 ohm Circuit)
Specifications
.15
Rated Voltage: 250VAC Maximum - 50/60 Hz
Rated Current:
Current Overload: 6X for 8 seconds
Hi-Pot Test (1 min):
Insulation Resistance: 9 x 10
Ambient Temperature: 40°C Max. at rated current
Humidity Range: 0% to 95% R.H.
Termination:
Maximum Leakage Current:
Agency Approvals:
58
40
58
36
56
40
Line to Ground
Line to Line
Each Line to Ground
115VAC, 60Hz:
250VAC, 50Hz:
A: QC – Quick Connect
B: Wire
C: IEC Receptacle
.50
65
60
65
55
65
50
Frequency - MHz
:
1.0
65
65
65
60
65
60
115VAC
10A
3A
6A
1500VAC
1768VDC
0.25mA
0.40mA
F1400
5.0
65
65
65
60
65
65
9
Ω at 100VDC
Specifications subject to change.
250VAC
1.5A
4A
6A
Dimensions are shown for
reference purposes only.
10
60
65
60
55
60
65
30
44
60
54
50
54
60

Related parts for F1400AA06

F1400AA06 Summary of contents

Page 1

... F1400 Simplified Schematic Nominal Part Current Number Rating F1400AA03 3A F1400BB03 F1400CA03 F1400AA06 6A F1400BB06 F1400CA06 10A F1400AA10 F1400BB10 NOTE: Other combinations of terminals may be specified on special order. 16 www.curtisind.com Specifications Rated Voltage: 250VAC Maximum - 50/60 Hz Rated Current: Current Overload: 6X for 8 seconds ...

Page 2

... Refer to Page 40 A for Standard D Mounting Cutouts D Amps A 2.880 3A (73,1) .250 QC 2.880 6A (6,4) (73,1) Curtis Industries A Division of Powers Holdings, Inc 2.000 1.500 2.940 2.500 .550 (50,8) (38,2) (74,7) (63,5) (14,0) 2.000 1.500 2.940 2.500 .550 (50,8) (38,2) (74,7) ...

Page 3

... CURRENT RATING Amp Amps Amps Amps Amps Amps .140 Dia Amps (3,55) 2 Holes .234 R. (5,94) (Typ.) Curtis Industries A Division of Powers Holdings, Inc. ✱.09 R (2,29) 1.275 (32,39) 1.145 ✱ for mounting (29,08) from back side 1.417 (36,0) 1.500 (38,1) .600 (15,2) N ...

Related keywords