215083-6 TE Connectivity, 215083-6 Datasheet - Page 6

Conn IDC Connector M 6 POS 2.54mm IDT RA Cable Mount T/R

215083-6

Manufacturer Part Number
215083-6
Description
Conn IDC Connector M 6 POS 2.54mm IDT RA Cable Mount T/R
Manufacturer
TE Connectivity
Type
IDC Connectorr
Series
Micro-MaTchr
Datasheets

Specifications of 215083-6

Pitch
2.54 mm
Number Of Rows
2
Number Of Contacts
6
Gender
M
Contact Plating
Tin Over Nickel
Termination Method
IDT
Connector Type
Wire-to-Board
Contact Material
Phosphor Bronze
Lead Spacing
1.27mm
No. Of Rows
2
No. Of Ways
6
Rohs Compliant
Yes
Product Type
Connector
Type Of Connector
Male-On-Wire
Wire/cable Type
Ribbon Cable
Insulation Diameter (mm [in])
0.90 [.035]
Polarization
Without
Number Of Positions
6
Wire Range (mm [awg])
0.08-0.09² [28]
Centerline (mm [in])
1.27 [0.050]
Contact Base Material
Phosphor Bronze
Contact Plating, Mating Area, Material
Tin
Housing Color
Red
Housing Material
Polyester GF
Rohs/elv Compliance
RoHS compliant, ELV compliant
Lead Free Solder Processes
Not relevant for lead free process
Rohs/elv Compliance History
Always was RoHS compliant
Applies To
Cable
Packaging Method
Reel
Packaging Quantity
2,500

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
215083-6
Manufacturer:
TE/AMP
Quantity:
30 000
Part Number:
215083-6
Manufacturer:
TE
Quantity:
20 000
Part Number:
215083-6
Manufacturer:
MOLEX
Quantity:
35 000
.
Rev. F
R6-77 (Rev. 07-01)
3.6.1.
3.6.2.
3.6.3.
3.6.4.
3.6.5.
Para.
3.6.6.
3.6.7.
3.6.8.
Examination of product
Solderability for through hole
versions
Resistance to soldering heat
for through hole versions
Solderability for SMD
Resistance to Soldering Heat
for SMD
Insulation resistance
Voltage proof
Termination resistance
Measuring points
Termination resistance
Test description
Test description
Meets requirements of product
drawing and applicable AMP
spec. 114-19016, 114-19051 or
114-19027.
Solderbath temp 235°C.
Ageing 3-16 hrs at 155°C
Max. 5% dewetting
Solderbath temp. 265°C
Dip duration: 10 seconds
Mount connectors in a PC-Board
as intended to be applied.
Requirement: No detrimental
effects.
Appearance of the specimen shall
be inspected after the test with
10x magnification of any damage
such as pinholes, void or rough
surface.
3 cycles of 260°C peak reflow
soldering simulation curve.
Test severity shall not include
moisture soak.
Requirement: No detrimental
effects.
Test voltage 100V DC- or AC-
peak. Duration: 1 minute.
Requirement: 1000 MΩ min.
Test voltage: 500 VAC.
Duration: 1 minute
Requirement: No break-down
or flash-over
Maximum open voltage 20
Millivolts. Maximum current 100
Milliampers. Termination
resistance consists of bulk cable +
bulk connectors and contact
resistance. Requirement: 10
Milliohms max. (excluding bulk
cable)
E L E C T R I C A L
Performance Requirements
Performance Requirements
VISUAL
or Severity
or Severity
Visual,
functional
inspection plan. In acc. with
IEC 512-2 test 1a.
Magnification 10 x.
In acc. with IEC 68-2-20
Test Ta
In acc. with:
Tyco Test Spec 109-202
Method § 4.3.B.
Provisional standards of EIA
of
( Test methods of soldering or
surface
Para 2.4.2. ( Reflow soldering
method )
In acc. with:
Tyco Test Spec 109-201
Reflow curve § 3.4.B.2.
In acc. with IEC 512-2 test 3a.
In acc. with IEC 512-2 test 4a.
In acc. with IEC 512-2 test 2a.
Under dry circuit conditions.
All contacts measured.
JAPAN.
Procedures
mounting
dimensional
Procedures
per
RCX-0102/101
108-19052
Page 6 of 15
applicable
devices)
and

Related parts for 215083-6