DRR-20A Delta Electronics, DRR-20A Datasheet - Page 2

no-image

DRR-20A

Manufacturer Part Number
DRR-20A
Description
MODULE REDUNDANCY 20A DIN RAIL
Manufacturer
Delta Electronics
Type
Isolatedr
Datasheet

Specifications of DRR-20A

Operating Temperature
-40°C ~ 80°C
Power (watts) - Rated
120W
Efficiency
97%
Approvals
CSA, cUL, EN, IEC, PELV, SELV, UL
Output
22 ~ 60V
Number Of Outputs
1
Power (watts)
120W
Mounting Type
DIN Rail
Voltage - Input
22 ~ 60V
Package / Case
Module
1st Output
22 ~ 60 VDC @ 20A
Size / Dimension
4.81" L x 1.97" W x 4.76" H (122.1mm x 50mm x 121mm)
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
2nd Output
-
3rd Output
-
4th Output
-
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
603-1633
Technical Data
Redundancy Module
1.) INPUT DATA
Nominal input voltage
Voltage range
Nominal current
Input voltage alarm / relay contacts
Note: The LED will turn on when The Vin1 & Vin2 > 18V +/- 5% (For 24V system) or > 36V +/- 5% (For 48V system) and not more than 30V (For 24V system)
or not more than 60V (For 48V system), The relay contacts will be closed. If Vin1 & Vin2 is under or over this range, The LED will be turn off.
2.) OUTPUT DATA
Nominal output voltage U
Nominal current
Derating above +50 °C
Short circuit / Over Load Limit
Note: The overload condition must be controlled by The PSUs in parallel; The limit of input current would not more than 25A (For 20A module) or not
more than 50A (For 60A module).
Efficiency
3.) CERTIFICATION / STANDARDS
Electrical equipment of machines
Electrical safety (information technology equipment)
Industrial Control Equipment
Electronic equipment for use in electrical power installations
Safety entry low voltage
RoHS Compliant
Protection against electric shock
4.) GENERAL DATA
Isolation voltage:
Degree of protection
Class of protection
MTBF
Type of housing
Dimensions (W / H / D) + mounting rail
Weight
LED (DC INPUT OK)
5.) CLIM ATIC DATA
Ambient temperature (Operating)
Ambient temperature (Storage)
Humidity
Vibration (Non-Operating)
Shock (in all directions)
Pollution degree
Climatic class
EMC (electromagnetic compatibility)
Immunity to interference :
According to EN 61000-6-2
EN55011 corresponds to CISPR11 / EN55022 corresponds to CISPR22 / EM 61000 corresponds to IEC 1000
1) Criterion A:
2) Criterion B:
3) Symmetrical: Conductor to conductor.
4) Asymmetrical: Conductor to ground.
5) Class B:
2/2
3/30/2011
Input / PE
output / PE
Discharge of static electricity (ESD)
Power frequency magnetic fields
EN 61000-4-2
EN 61000-4-3
Radiate Field Immunity
EN 61000-4-8
Conformance with EMC guideline
2004/108/EC and for low voltage guideline
2006/95/EC :
at+25 °C, no condensation
Temporary impairment to operational behavior that is corrected by the device itself.
Normal operating behavior within the defined limits.
Area of application industry and residential.
1)
1)
2)
N
/ tolerance
Redundancy Module
Frequency/Field intensity:
type test/routine test:
type test/routine test:
Contact discharge:
Air Discharge:
Housing:
Housing:
Current:
Input:
IEC60068-2-27, 30G (300m/s2) for duration 18ms 1 Shock in 2 Directions tested with Fixture with
10Hz to 500Hz @ 30 m/S2 (3G peak); displacement of 0.35mm; 60min per axis for all X, Y, Z
UR/cUR recognized to UL60950-1, SIQ BG to EN60950-1, CB test certificate and report to
direction. Refer to IEC 60068-2-6. Note: all figures quoted are amplitudes (peak values)
both Vin1 & Vin2 >18V +/- 5% or
DRR-20A (EOE21010284)
<30V max. relay contacts
(<25A for DRR- 20A)
DRR- 20A
Technical Information
24V system:
EUT mounted on DINRAIL in Vertical and Horizontal position.
20A max
0.375Kg
80MHz - 1GHz / 10V/M with 1kHz tone / 80% modulation
> 800,000hrs. as per BELL CORE STD or IEC61709
121 mm X 50 mm X 122.1 mm (L X W X H)
IEC60204-1 (over voltage category III)
Yes, RoHS directive, WEEE directive
Vin1 OK and Vin2 OK (GREEN LED)
CE (EMC and Low Voltage directive)
PELV (EN60204), SELV (EN60950)
- 40°C to 80°C (> 50°C derating)
UL/cUL recognize to UL508
3K3 according to EN 60721
Class II with PE connection
2 according to EN50178
IEC60950-1 and CE.
1.5 KVAC / 1.5 KVAC
1.5 KVAC / 1.5 KVAC
Aluminium (AL1100F)
EN50178 / IEC62103
20A max / 40A max
> 50°C (2.5% / K.)
Vin-0.65V (Typ)
DIN 57100-410
- 40°C to 85°C
> 97% typical.
24-48VDC
22-60VDC
< 95% RH
10A/meter
LEVEL 4
LEVEL 3
Level 3
15 KV
8 KV
IP20
both Vin1 & Vin2 >36V +/- 5% or
DRR-40A(EOE21010285)
<60V max. relay contacts
(<50A for DRR- 40A)
DRR- 40A
48V system:
40A max
0.515Kg
DRR-20A / DRR-40A