MCP3553-E/SN Microchip Technology, MCP3553-E/SN Datasheet - Page 24

no-image

MCP3553-E/SN

Manufacturer Part Number
MCP3553-E/SN
Description
IC ADC 22BIT 2.7V 1CH SPI 8SOIC
Manufacturer
Microchip Technology
Datasheets

Specifications of MCP3553-E/SN

Package / Case
8-SOIC (0.154", 3.90mm Width)
Number Of Bits
22
Sampling Rate (per Second)
60
Data Interface
Serial, SPI™
Number Of Converters
1
Voltage Supply Source
Single Supply
Operating Temperature
-40°C ~ 125°C
Mounting Type
Surface Mount
Architecture
Delta-Sigma
Conversion Rate
0.06 KSPs
Input Type
Voltage
Maximum Operating Temperature
+ 85 C
Mounting Style
SMD/SMT
Minimum Operating Temperature
- 40 C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With
MCP355XDV-MS1 - BOARD DEV SENSOR APP MCP355XMCP355XDM-TAS - BOARD DEMO TINY APP SNSR MCP355X
Lead Free Status / Rohs Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MCP3553-E/SN
Manufacturer:
MICROCHIP
Quantity:
12 000
MCP3550/1/3
5.4.1
The device enters Continuous Conversion mode if no
rising edge of CS is seen during t
consecutive conversions ensue. SDO/RDY will be
high, indicating that a conversion is in process. When
a conversion is complete, SDO/RDY will change to a
Low state. With the Low state of SDO/RDY after this
first conversion, the conversion data can be accessed
with the combination of SCK and SDO/RDY. If the data
ready event happens during the clocking out of the
data, the data ready bit will be displayed after the
complete 24-bit word communication (i.e., the data
ready event will not interrupt a data transfer).
If 24 bits of data are required from this conversion, they
must be accessed during this communication. You can
terminate data transition by bringing CS high, but the
remaining data will be lost and the converter will go into
Shutdown mode. Once the data has been transmitted
by the converter, the SDO/RDY pin will remain in the
LSB state until the 25th falling edge of SCK. At this
point, SDO/RDY is released from the Data Acquisition
mode and changed to the RDY state.
DS21950E-page 24
Note:
READY FUNCTION OF SDO/RDY
PIN IN CONTINUOUS CONVERSION
MODE
The RDY state is not latched to CS in this
mode; the RDY flag dynamically updates
on the SDO/RDY pin and remains in this
state until data is clocked out using the
SCK pin.
CONV
and
5.4.2
It is possible to use only two wires to communicate with
the MCP3550/1/3 devices. In this state, the device is
always in Continuous Conversion mode, with internal
conversions continuously occurring. This mode can be
entered by having CS low during power-up or changing
it to a low position after power-up. If CS is low at power-
up, the first conversion of the converter is initiated
approximately 300 µs after the power supply has
stabilized.
2-WIRE CONTINUOUS
CONVERSION OPERATION,
(CS TIED PERMANENTLY LOW)
© 2009 Microchip Technology Inc.