X9C102P Intersil, X9C102P Datasheet - Page 7

no-image

X9C102P

Manufacturer Part Number
X9C102P
Description
IC DIGITAL POT 1K 100TP 8DIP
Manufacturer
Intersil
Series
XDCP™r
Datasheet

Specifications of X9C102P

Taps
100
Resistance (ohms)
1K
Number Of Circuits
1
Temperature Coefficient
600 ppm/°C Typical
Memory Type
Non-Volatile
Interface
Up/Down (3-Wire)
Voltage - Supply
4.5 V ~ 5.5 V
Operating Temperature
0°C ~ 70°C
Mounting Type
Through Hole
Package / Case
8-DIP (0.300", 7.62mm)
Resistance In Ohms
1.00K
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
X9C102P
Quantity:
3
Part Number:
X9C102P
Manufacturer:
Intersil
Quantity:
1
Part Number:
X9C102P
Manufacturer:
XICOR
Quantity:
20 000
Part Number:
X9C102PI
Manufacturer:
Intersil
Quantity:
1
Part Number:
X9C102PI
Manufacturer:
XICOR
Quantity:
20 000
Part Number:
X9C102PIZ
Manufacturer:
Intersil
Quantity:
100
Part Number:
X9C102PIZ
Manufacturer:
Intersil
Quantity:
500
Part Number:
X9C102PIZ
Manufacturer:
INTERSIL
Quantity:
20 000
Company:
Part Number:
X9C102PIZ
Quantity:
5 400
Instructions and Programming
The INC, U/D and CS inputs control the movement of the
wiper along the resistor array. With CS set LOW, the device is
selected and enabled to respond to the U/D and INC inputs.
HIGH to LOW transitions on INC will increment or decrement
(depending on the state of the U/D input) a 7-bit counter. The
output of this counter is decoded to select one of one-hundred
wiper positions along the resistive array.
The value of the counter is stored in non-volatile memory
whenever CS transitions HIGH while the INC input is also
HIGH.
The system may select the X9Cxxx, move the wiper and
deselect the device without having to store the latest wiper
position in non-volatile memory. After the wiper movement is
performed as previously described and once the new
position is reached, the system must keep INC LOW while
taking CS HIGH. The new wiper position will be maintained
until changed by the system or until a power-down/up cycle
recalled the previously stored data.
This procedure allows the system to always power-up to a
pre-set value stored in non-volatile memory; then during
system operation, minor adjustments could be made. The
adjustments might be based on user preference, i.e.: system
parameter changes due to temperature drift, etc.
The state of U/D may be changed while CS remains LOW.
This allows the host system to enable the device and then
move the wiper up and down until the proper trim is attained.
7
X9C102, X9C103, X9C104, X9C503
Mode Selection
Symbol Table
Performance Characteristics
Contact the factory for more information.
Applications Information
Electronic digitally controlled (XCDP) potentiometers provide
three powerful application advantages:
1. The variability and reliability of a solid-state
2. The flexibility of computer-based digital controls.
3. The retentivity of non-volatile memory used for the
CS
H
L
L
potentiometer.
storage of multiple potentiometer settings or data.
WAVEFORM
INC
H
X
L
L
L
U/D
H
H
L
X
X
X
L
INPUTS
Must be
steady
May change
from Low to
High
May change
from High to
Low
Don’t Care:
Changes
Allowed
N/A
Wiper Up
Wiper Down
Store Wiper Position
Standby Current
No Store, Return to Standby
Wiper Up (not recommended)
Wiper Down (not recommended)
OUTPUTS
Will be
steady
Will change
from Low to
High
Will change
from High to
Low
Changing:
State Not
Known
Center Line
is High
Impedance
MODE
July 20, 2009
FN8222.3

Related parts for X9C102P