BTS117E3044ANT Infineon Technologies, BTS117E3044ANT Datasheet
BTS117E3044ANT
Specifications of BTS117E3044ANT
Related parts for BTS117E3044ANT
BTS117E3044ANT Summary of contents
Page 1
... Analog driving possible Application • All kinds of resistive, inductive and capacitive loads in switching or linear applications • µC compatible power switch for 12 V and applications • Replaces electromechanical relays and discrete circuits General Description N channel vertical power FET in Smart SIPMOS chip on chip tech- nology ...
Page 2
Maximum Ratings °C unless otherwise specified Parameter Drain source voltage Drain source voltage for short circuit protection Continuous input current 1) -0.2V ≤ V ≤ 10V IN V < -0. > 10V IN IN ...
Page 3
Electrical Characteristics Parameter at T =25°C, unless otherwise specified j Characteristics Drain source clamp voltage ...+ 150° Off state drain current -40...+150 °C, V ...
Page 4
... Inverse Diode Inverse diode forward voltage = 300 µ 5*3.5A Device switched on into existing short circuit (see diagram Determination of I D(lim the device condition and a short circuit occurs, these values might be exceeded for max. 50 µs. Symbol I D(SCp) I D(lim) = 350 µ ...
Page 5
Block Diagramm Terms HITFET Input circuit (ESD protection) IN ESD-ZD I Source ESD zener diodes are not designed for DC current > >10V. IN Inductive and ...
Page 6
Maximum allowable power dissipation P = f(T ) tot c BTS 117 On-state resistance 3.5A; V =5V ...
Page 7
Typ. transfer characteristics =12V; T =25° Transient thermal impedance thJC p parameter : D = ...
Page 8
Application examples: Status signal of thermal shutdown by monitoring input current HITFET µC µ ∆ IN( ∆ V thermal shutdown Page 8 BTS 117 19.05.2000 ...
Page 9
... For information on the types in question please contact your nearest Infineon Technologies Office. Infineon Technologies Components may only be used in life-support devices or systems with the express written approval of Infineon Technologies failure of such components can reasonably be expected to cause the failure of that life-support device or system affect the safety or effectiveness of that device or system Life support devices or systems are intended to be implanted in the human body support and/or maintain and sustain and/or protect human life ...