NFS110-7902PJ ARTESYN, NFS110-7902PJ Datasheet - Page 3

no-image

NFS110-7902PJ

Manufacturer Part Number
NFS110-7902PJ
Description
AC/DC Power Supply Quad-OUT 5.1V/24V/12V/-12V 8A/3.5A/4.5A/0.5A 110W 16-Pin
Manufacturer
ARTESYN
Datasheet

Specifications of NFS110-7902PJ

Input Voltage
90 to 253 V
Output Voltage
5.1|24|12|-12 V
Maximum Output Current
8|3.5|4.5|0.5 A
Number Of Outputs
4
Maximum Output Power
110 W
Efficiency
70(Typ) %
Input Frequency
47 to 440 Hz
Operating Temperature
0 to 70 °C
Notes
1
2
3
4
5
6
7
8
9
10 The user should read the PSU installation instructions in conjunction with the
11 Three orthogonal axes, random vibration, 10 minute test for each axis.
12 This product is only for inclusion by professional installers within other
13 The ‘J’ suffix indicates that these parts are Pb-free (RoHS 6/6) compliant. TSE
14 NOTICE: Some models do not support all options. Please contact your local
Ordering Information
Convection cooled, 80 W maximum.
Peak outputs lasting less than 60 seconds with duty cycle less than 10%. Total
peak power must not exceed 110 W.
Forced air, 20 CFM at 1 atmosphere, 110 W maximum.
Figure is peak-to-peak. Output ripple is measured across a 50 MHz bandwidth
using a 12 inch twisted pair terminated with a 47 μF capacitor.
Total regulation is defined at the static output regulation at 25 °C, including
initial tolerance, line voltage within stated limits and output voltages adjusted
to their factory settings. Also for NFS110-7902PJ, for 24 V output stated
regulation I
I
Single output models have floating outputs which may be referenced as either
positive or negative. Higher voltage supplies, may be adjusted over a wide
output voltage range, as long as the total output power does not exceed 80
Watts (natural convection) or 110 Watts (forced air).
Power fail detect not available on single output models.
Derating curve is application specific for ambient temperatures > 50 °C, for
optimum reliability no part of the heatsink should exceed 90 °C and no
semiconductor case temperature should exceed 100 °C.
Caution: Allow a minimum of 1 second after disconnecting the power when
making thermal measurements.
relevant national safety regulations in order to ensure compliance.
equipment and must not be operated as a stand alone product.
RoHS 5/6 (non Pb-free) compliant versions may be available on special request,
please contact your local sales representative for details.
Emerson Network Power representative or use the on-line model number
search tool at http://www.powerconversion.com to find a suitable alternative.
+5.1 V
+12 V
–12 V
–5 V
+5.1 V (I A )
+24 V (I B )
+12 V
–12 V
+5.1 V
+15 V
–15 V
–5 V
12 V
15 V
24 V
A
Voltage
² 5 A, where I
Output
A
(6)
/ I
B
A
² 5. This output will maintain
= +5.1 V output current and I
8 A
4.5 A
0.5 A
0.5 A
8 A
3.5 A
4.5 A
0.5 A
8 A
4 A
0.5 A
0.5 A
7 A
5 A
3.5 A
Max
(1)
Output Currents
20 A
9 A
1.5 A
1.5 A
20 A
4.5 A
9 A
1.5 A
20 A
7.5 A
1.5 A
1.5 A
9 A
7.3 A
4.5 A
Peak
±
B
5.0% regulation if
= +24 V output current.
(2)
10 A
5 A
1 A
1 A
10 A
4.5 A
5 A
1 A
10 A
5 A
1 A
1 A
9 A
7.3 A
4.5 A
Fan
(3)
TRANSIENT RESPONSE
NFS110-7901PJ
NFS110-7902PJ
NFS110-7904PJ
NFS110-7905J
NFS110-7912J
NFS110-7915J
NFS110-7924J
Ripple
50 mV
120 mV
120 mV
50 mV
50 mV
240 mV
120 mV
120 mV
50 mV
150 mV
150 mV
50 mV
120 mV
150 mV
240 mV
(4)
Regulation
±2.0%
±3.0%
±3.0%
±3.0%
±2.0%
+10/–5.0%
±3.0%
±3.0%
±2.0%
±4.0%
±3.0%
±3.0%
±2.0%
±2.0%
±2.0%
Total
+5.1 V (7.5-10 A)
+12 V (2.5-5 A)
-12 V (0.5-1 A)
-5 V (0.5-1 A)
+5.1 V (7.5-10 A)
+12 V (2.5-5 A)
-12 V (0.5-1 A)
24 V (1.5-3 A)
+5.1 V (7.5-10 A)
+15 V (2.5-5 A)
-15 V (0.5-1 A)
-5 V (0.5-1 A)
+5.1 V (10-20 A)
+12 V (4.5-9 A)
+15 V (3.65-7.3 A)
+24 V (2.25-4.5 A)
(5)
NFS110-7901PJ
NFS110-7902PJ
NFS110-7904PJ
NFS110-7912J
NFS110-7915J
NFS110-7924J
Model Numbers
Embedded Power for
Business-Critical Continuity
(7,8)
(7,8)
(7,8)
(13, 14, F)
0.5 ms recovery
0.5 ms recovery
0.5 ms recovery
0.5 ms recovery
0.5 ms recovery
0.5 ms recovery
0.5 ms recovery
0.5 ms recovery
1 ms recovery
1 ms recovery
1 ms recovery
1 ms recovery
1 ms recovery
1 ms recovery
1 ms recovery
150 mV peak,
100 mV peak,
100 mV peak,
100 mV peak,
150 mV peak,
100 mV peak,
100 mV peak,
300 mV peak,
150 mV peak,
100 mV peak,
100 mV peak,
100 mV peak,
250 mV peak,
360 mV peak,
450 mV peak,
720 mV peak,
NFS110 Series
Rev. 06.10.08
3 of 5