EP1S25F1020I6 Altera, EP1S25F1020I6 Datasheet - Page 50

no-image

EP1S25F1020I6

Manufacturer Part Number
EP1S25F1020I6
Description
IC STRATIX FPGA 25K LE 1020-FBGA
Manufacturer
Altera
Series
Stratix®r
Datasheet

Specifications of EP1S25F1020I6

Number Of Logic Elements/cells
25660
Number Of Labs/clbs
2566
Total Ram Bits
1944576
Number Of I /o
706
Voltage - Supply
1.425 V ~ 1.575 V
Mounting Type
Surface Mount
Operating Temperature
-40°C ~ 100°C
Package / Case
1020-FBGA
Family Name
Stratix
Number Of Logic Blocks/elements
25660
# I/os (max)
706
Frequency (max)
450.05MHz
Process Technology
0.13um (CMOS)
Operating Supply Voltage (typ)
1.5V
Logic Cells
25660
Ram Bits
1944576
Operating Supply Voltage (min)
1.425V
Operating Supply Voltage (max)
1.575V
Operating Temp Range
-40C to 100C
Operating Temperature Classification
Industrial
Mounting
Surface Mount
Pin Count
1020
Package Type
FC-FBGA
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Number Of Gates
-
Lead Free Status / Rohs Status
Not Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EP1S25F1020I6
Manufacturer:
ALTERA
Quantity:
5 510
Part Number:
EP1S25F1020I6
Manufacturer:
MOT
Quantity:
5 510
Part Number:
EP1S25F1020I6
Manufacturer:
ALTERA
Quantity:
3 000
Part Number:
EP1S25F1020I6
Manufacturer:
Altera
Quantity:
10 000
Part Number:
EP1S25F1020I6
Manufacturer:
ALTERA
0
Part Number:
EP1S25F1020I6
Manufacturer:
ALTERA
Quantity:
20 000
Part Number:
EP1S25F1020I6N
Manufacturer:
ALTERA
Quantity:
3 000
Part Number:
EP1S25F1020I6N
Manufacturer:
Altera
Quantity:
10 000
Part Number:
EP1S25F1020I6N
Manufacturer:
ALTERA
0
Part Number:
EP1S25F1020I6N
Manufacturer:
ALTERA
Quantity:
20 000
TriMatrix Memory
2–36
Stratix Device Handbook, Volume 1
Similar to all RAM blocks, M-RAM blocks can have different clocks on
their inputs and outputs. All input registers—renwe, datain, address,
and byte enable registers—are clocked together from either of the two
clocks feeding the block. The output register can be bypassed. The eight
labclk signals or local interconnect can drive the control signals for the
A and B ports of the M-RAM block. LEs can also control the clock_a,
clock_b, renwe_a, renwe_b, clr_a, clr_b, clocken_a, and
clocken_b signals as shown in
Notes to
(1)
(2)
Table 2–11. M-RAM Combined Byte Selection for ×144 Mode
Any combination of byte enables is possible.
Byte enables can be used in the same manner with 8-bit words, i.e., in × 16, × 32,
× 64, and × 128 modes.
Tables 2–10
byteena[15..0]
[10] = 1
[11] = 1
[12] = 1
[13] = 1
[14] = 1
[15] = 1
[0] = 1
[1] = 1
[2] = 1
[3] = 1
[4] = 1
[5] = 1
[6] = 1
[7] = 1
[8] = 1
[9] = 1
and 2–11:
Figure
2–19.
datain ×144
[116..108]
[125..117]
[134..126]
[143..135]
[107..99]
[26..18]
[35..27]
[44..36]
[53..45]
[62..54]
[71..63]
[80..72]
[89..81]
[98..90]
[17..9]
[8..0]
Altera Corporation
Notes
July 2005
(1),
(2)