SDV-FL61 Omron, SDV-FL61 Datasheet - Page 97

no-image

SDV-FL61

Manufacturer Part Number
SDV-FL61
Description
Sensor Hardware & Accessories VOLTAGE SENSOR
Manufacturer
Omron
Datasheets

Specifications of SDV-FL61

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Connections
Note: 1. *Type LG2-DB is not equipped with the rectifier circuit.
Nomenclature
Setting Method
Operate Value
Input the actual voltage to be set, and set the SET knob to the point
at which the Relay operates.
Release Value
• With the Relay operating, turn the RESET knob counterclockwise
Note: After completing the settings, check the settings for the operate
• The LG2 can be used for undervoltage detection by using the
RESET knob
as far as it will go, and adjust the voltage to the value to be set.
Then, gradually turn the RESET knob clockwise until it reaches the
point where the Relay is released.
RESET knob for the operate value and the SET knob for the
release value. The Relay will normally be ON, however, and so the
internal temperature will rise, and this will affect the product service
life.
Terminal Arrangement
2. With type LG2-DB, care should be taken to the polarity of
and release values by increasing/decreasing the input voltage.
the power supply.
The polarity indication for
terminals
to the DC model (LG2-DB).
(The above diagram shows
the rear side of the Relay.)
3
2
4
1
and
( )
5
8
VOLTAGE SENSOR
LG2-DB
RESET
70to115%
VOLTAGE
applies
6
7
70to120%
12VDC
SET
(The above diagram shows
the rear side of the Relay.)
3
2
4
1
5
8
SET knob
6
7
Voltage Sensor
LG2
95