MR62-5UKSRY NEC, MR62-5UKSRY Datasheet
MR62-5UKSRY
Specifications of MR62-5UKSRY
Available stocks
Related parts for MR62-5UKSRY
MR62-5UKSRY Summary of contents
Page 1
... As of May 2007, the MR62 series is being listed as a non-promotional item and is not for use in new designs. The MR62 series is a nonlatch type relay with 2 from c contact arrangements, and suitable for the switching of signals in telecommunications equipment, an industrial equipment, audio/visual sets, and so forth. ...
Page 2
... The tolerance is ±0.2 (0.008) unless otherwise specified. The dimension in the box shows basic size. MAKING (SIDE VIEW) General type MR62-5KSRY <1> <2> JAPAN <3> UL recognized, CSA certified type MR62-5UKSRY <1> JAPAN <2> 0.6 A 110 VDC VDC 1 A 125 VAC 2 PAD LAYOUT Unit: mm (inch (0.039) φ ...
Page 3
... Ambient Temperature Coil Temperature Rise Running Specifications Nonload Load Weight *1 for one minute *2 rise time: 10 μ s, decay time to half crest: 160 μ s. PART NUMBER SYSTEM MR62-5UKSRY Nominal operate power Nil : 550 400 mW Contact material Nil : Silver-palladium alloy with gold alloy overlay ...
Page 4
... Must Operate Voltage (Ω)±10% (Vdc) 62.5 3.5 90 4.2 202.5 6.3 360 8.4 1440 16.8 5760 34.4 Data Sheet ER0515EJ1V0DS MR62 SERIES (at 20°C) Must Release Voltage (Vdc) 0.25 0.33 0.45 0.68 1.3 2.6 (at 20°C) Must Release Voltage (Vdc) 0.25 0.33 0.45 ...
Page 5
... Must Operate Voltage (Ω)±10% (Vdc) 42 3.5 66 4.2 140 6.3 280 8.4 1050 16.8 4200 38.4 Data Sheet ER0515EJ1V0DS MR62 SERIES (at 20°C) Must Release Voltage (Vdc) 0.25 0.33 0.45 0.68 1.3 2.6 (at 20°C) Must Release Voltage (Vdc) 0.25 0.33 0.45 ...
Page 6
... Must Operate Voltage (Ω)±10% (Vdc) 62.5 3.5 90 4.2 202.5 6.3 360 8.4 1440 16.8 5360 38.4 Data Sheet ER0515EJ1V0DS MR62 SERIES (at 20°C) Must Release Voltage (Vdc) 0.25 0.33 0.45 0.68 1.3 2.6 (at 20°C) Must Release Voltage (Vdc) 0.25 0.33 0.45 ...
Page 7
... Contact voltage (V) APPLIED VOLTAGE vs. TIMING MAX MIN 0.5 1.0 1.5 Applied power (W) RUNNING TEST (Nonload) Sample: MR62-5SR 20 pieces Driving dc, 50 Hz, 50% duty Operate voltage Relese voltage Operations (× RUNNING TEST (Load) Sample: MR62-5SR 10 pieces Load dc, 0.1 A Resistive ...
Page 8
... Dimension of Relay Tube (Unit: mm) 11.8 Outline of Package Rubber stopper (red) Rubber stopper (green) 8 Alternation of release voltage +40 +30 +20 +10 0 –10 –20 –30 – OFF OFF III IV OFF OFF OFF VI 25 pieces/tube Material: Polyvinyl chloride (anti-static treated) 534 Data Sheet ER0515EJ1V0DS MR62 SERIES Mounting layout 2.54 mm ...
Page 9
... Because the operating temperature range varies depending on the humidity, use the relay in the temperature range illustrated in the figure below. Prevent the relay from being frozen and avoid the generation of condensation max. Data Sheet ER0515EJ1V0DS MR62 SERIES 9 ...
Page 10
... The storage humidity must be no more than 70% RH. The recommended storage period is 3 months maximum store the relay for 3 months or longer, keep the storage humidity to within 50% RH. Do not store the relay for more than 6 months 100 Temperature (°C) Data Sheet ER0515EJ1V0DS MR62 SERIES (1,000 G) or more 2 ...
Page 11
... Special specifically designed for life support systems, life support systems or medical equipment for life support, etc. The quality grade of NEC devices is "Standard" unless otherwise specified in NEC's Data Sheets " " " " 3/01 MR62 SERIES DE0202 ...