5-1415033-1 Tyco Electronics, 5-1415033-1 Datasheet

Safety Relays SR6ZB024

5-1415033-1

Manufacturer Part Number
5-1415033-1
Description
Safety Relays SR6ZB024
Manufacturer
Tyco Electronics
Datasheet

Specifications of 5-1415033-1

Other names
SR6ZB024
n
n
n
Typical applications
contact monitoring in railway, elevator and machine controls
10-2012, Rev. 1012
www.te.com
© 2012 Tyco Electronics Corporation,
a TE Connectivity Ltd. company
Approvals
relay SR6: VDE, UL, TUV, CQC
module SR6Z: CE
Technical data of approved types on request
Contact Data
Contact arrangement
Rated voltage
Max. switching voltage
Rated current
Contact material
Contact style
Min. recommended contact load
Initial contact resistance
Frequency of operation, with/without load
Contact ratings, IEC60947-5-1,
Mechanical endurance
Coil Data
Coil voltage range
DC energizing voltage U
AC/DC energizing voltage U
AC energizing voltage U
Operative range
Release voltage (+23°C)
Max. coil power DC versions
Max. system power AC/DC versions
Insulation Data
Initial dielectric strength
Clearance/creepage
Insulation to EN 50178, type of insulation
6 pole relay with force guided contacts according to EN50205
DIN rail mounting
AC / DC input
on 1 form A (NO) contact
between open contacts
between contact and coil
between adjacent contacts
between open contacts
between contact and coil
between adjacent contacts
between contact and coil
between adjacent contacts
rtd
rtd
rtd
3 form A (NO) and 3 form B (NC),
4 form A (NO) and 2 form B (NC),
5 form A (NO) and 1 form B (NC)
6, 12, 18, 21, 24, 36, 40, 48, 60, 115VDC
type A according to EN 50205
Datasheets and product specification
according to IEC 61810-1 and to be used
only together with the ‘Definitions’ section.
single contact, force guided
≤100mΩ at 1A, 24VDC
≤20Ω at 10mA, 5VDC
microdisconnection
6 to 115 VAC/VDC,
90 to 110% of U
10x10
24, 115VAC/VDC
≥2,8 /2.8mm
≥5.5/5.5mm
10% of U
6/150min
2400mVA
reinforced
5V, 10mA
DC13-6A
AC15-5A
1200mW
1000V
3000V
2000V
AgSnO
250VAC
250VAC
230VAC
230VAC
6
basic
General Purpose Relays
Force Guided Relays
Force Guided Relay on DIN-rail SR6 Z
8A
operations
rms
rms
rms
2,
rtd
-1
rtd
54.0 mm (TS35)
Datasheets and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.te.com/definitions
Other Data
Material compliance: EU RoHS/ELV, China RoHS, REACH, Halogen content
Ambient temperature
Terminal type
Wire cross section
Mounting position
Weight
Packaging unit
Dimensions
Module width 46 mm
Module length 87 mm
for mounting/handling
in operation
SR6ZC 730 only
solid wire
stranded wire
stranded wire with bootlace crimp
refer to the Product Compliance Support Center at
www.te.com/customersupport/rohssupportcenter
Fit onto mounting rails according to
DIN EN 60175
Datasheets, product data, ‘Definitions’ sec-
tion, application notes and all specifications
are subject to change.
screwless clamp connectors
-25 to 50°C
-25 to 40°C
0 to 40°C
2.5mm
2.5mm
1.5mm
90g
any
2
SCHRACK
2
2
2
S0423-A
F0238-C
1