EMC6D103-CZC-TR SMSC, EMC6D103-CZC-TR Datasheet - Page 24

no-image

EMC6D103-CZC-TR

Manufacturer Part Number
EMC6D103-CZC-TR
Description
Industrial Temperature Sensors Auto Fan Contrllr Up to 4 Fans
Manufacturer
SMSC
Datasheet

Specifications of EMC6D103-CZC-TR

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Revision 0.3 (03-01-07)
6.3.1
6.3.2
Continuous Monitoring Mode
In the continuous monitoring mode, the sampling and conversion process is performed continuously
for each voltage and temperature reading after the Start bit is set high. The time for each voltage and
temperature reading is shown above for each measurement option.
The continuous monitoring function is started by doing a write to the Ready/Lock/Start Register, setting
the Start bit (Bit 0) high. The part then performs a “round robin” sampling of the inputs, in the order
shown below (see
Table 6.2, “Conversion Cycle Timing,” on page
When the continuous monitoring function is started, it cycles through each measurement in sequence,
and it continuously loops through the sequence approximately once every 223 ms (default - see
Table 6.2, “Conversion Cycle Timing,” on page
in the Limit registers. When the measured value violates the programmed limit the Hardware Monitor
Block will set a corresponding status bit in the Interrupt Status Registers.
If auto fan option is selected, the hardware will adjust the operation of the fans accordingly. See
Fan Control Operating Mode on page
The results of the sampling and conversions can be found in the Reading Registers and are available
at any time.
Cycle Monitoring Mode
In cycle monitoring mode, the part completes all sampling and conversions, then waits approximately
one second to repeat the process. It repeats the sampling and conversion process typically every 1.2
seconds (1.4 sec max - default averaging enabled). The sampling and conversion of each voltage and
temperature reading is performed once every monitoring cycle. This is a power saving mode.
The cycle monitoring function is started by doing a write to the Ready/Lock/Start Register, setting the
Start bit (Bit 0) high. The part then performs a “round robin” sampling of the inputs, in the order shown
above.
When the cycle monitoring function is started, it cycles through each measurement in sequence, and
it produces a converted voltage and temperature reading for each input. The state machine waits
approximately one second before repeating this process. Each measured value is compared to values
stored in the Limit registers. When the measured value violates (or is equal to) the programmed limit
the Hardware Monitor Block will set a corresponding status bit in the Interrupt Status Registers.
SAMPLING ORDER
Table
Fan Control Device with High Frequency PWM Support and Hardware Monitoring Features
1
2
3
4
5
6
7
8
Table 6.3 ADC Conversion Sequence
6.3). Sampling of all values occurs in a nominal 223 ms (default - see
DATASHEET
34.
Remote Diode Temp Reading 1
Remote Diode Temp Reading 2
Ambient Temperature reading
24
Vccp (processor) reading
23). Each measured value is compared to values stored
23).
+2.5V reading
+12V reading
VCC reading
+5V reading
REGISTER
SMSC EMC6D103