E2E-X1R5F1 Omron Automation, E2E-X1R5F1 Datasheet - Page 8

no-image

E2E-X1R5F1

Manufacturer Part Number
E2E-X1R5F1
Description
Sensor; 0.59 in.; 12 to 24 VDC; 13 mA (Max.); Shielded; 2 kHz; 85 degC;
Manufacturer
Omron Automation
Type
Inductiver
Datasheet

Specifications of E2E-X1R5F1

Body Style
Cylindrical
Current, Consumption
13 mA (Max.)
Current, Switching
200 mA
Dimensions
1.18 in. L
Frequency, Switching
2 kHz
Function
Proximity
Ip Rating
IP67
Material, Housing
Stainless Steel (Body), PBT (Sensing Face)
Mounting Type
Bracket/DIN Rail
Output
PNP-NO
Primary Type
Proximity
Range, Measurement
1.5 mm
Technology
Inductive
Temperature, Ambient, Maximum
85 °C
Temperature, Ambient, Minimum
-40 °C
Termination
Pre-Wired
Voltage, Supply
24 VDC
Voltage, Switching
3 V
Supply Voltage Range
10-30 VDC or 20-264 VAC, 50/60 Hz (Model Dependant)
Load Rating
100/200 mA (DC) or 5-100 mA/5-200 mA/5-300 mA (AC) (Model Dependant)
Approvals
CE, UL, CSA (Model Dependant)
Lead Free Status / Rohs Status
RoHS Compliant part

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
E2E-X1R5F1
Manufacturer:
OMRON
Quantity:
1 000
Part Number:
E2E-X1R5F1
Manufacturer:
OMRON
Quantity:
374
Part Number:
E2E-X1R5F1-Z
Manufacturer:
EVERLIGHT
Quantity:
52 730
Ratings and Specifications
E2E-X@D@ DC 2-Wire Models
*1. Use the E2E within the range in which the setting indicator (green LED) is ON (except D2 Models).
*2. The response frequency is an average value.
*3. The residual voltage of each M1J-T Model is 5 V. When connecting to a device, make sure that the device can withstand the residual voltage. (Refer to page 23 for
Item
Sensing distance
Set distance *1
Differential travel
Detectable object
Standard sensing
object
Response frequency
*2
Power supply voltage
(operating voltage
range)
Leakage current
Control
output
Indicators
Operation mode
(with sensing object
approaching)
Diagnostic output
delay
Protection circuits
Ambient
temperature range
Ambient
humidity range
Temperature
influence
Voltage influence
Insulation resistance
Dielectric strength
Vibration resistance
Shock resistance
Degree of protection
Connection method
Weight
(pack-
ed
state)
Materi-
als
Accessories
Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and a set distance of half the sensing distance.
details.)
Pre-wired
Models
Pre-wired
Connector
Models
Connector
Models
Case
Sensing sur-
face
Clamping
nuts
Toothed
washer
Load
current
Residual
voltage
*3
Shielded
Model E2E-X2D@
Size
2 mm ±10%
0 to 1.6 mm
15% max. of sensing distance
Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on pages 13 and 14.
Iron,
8 × 8 × 1 mm
1.5 kHz
12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max.
0.8 mA max.
3 to 100 mA, Diagnostic output: 50 mA for -D1(5)S Models
3 V max. (Load current: 100 mA, Cable length: 2 m, M1J-T Models only: 5 V max.)
D1 Models: Operation indicator (red) and setting indicator (green)
D2 Models: Operation indicator (red)
D1 Models: NO
D2 Models: NC
0.3 to 1 s
Surge suppressor, Load short-circuit protection (for control and diagnostic output)
Operating: −25 to 70°C, Storage: −40 to 85°C (with no icing or condensation)
Operating/storage: 35% to 95% (with no condensation)
±15% max. of sensing distance
at 23°C in the temperature range
of −25 to 70°C
±1% max. of sensing distance at rated voltage in the rated voltage ±15% range
50 MΩ min. (at 500 VDC) between current-carrying parts and case
1000 VAC, 50/60 Hz for 1 minute between current carry parts and case
Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Destruction: 500 m/s
10 times each in X, Y, and
Z directions
Pre-wired Models : IEC 60529 IP67, in-house standards: oil-resistant
Connector Models : IEC 60529 IP67
Pre-wired Models (Standard cable length: 2 m), Connector Models, or Pre-wired Connector Models (Standard cable length: 0.3 m)
Approx. 60 g
Approx. 15 g
Stainless steel (SUS303)
PBT
Nickel-plated brass
Zinc-plated iron
Instruction manual
Shielded
M8
---
E2E-X4MD@
4 mm ±10%
0 to 3.2 mm
Iron,
20 × 20 × 1 mm
1 kHz
Unshielded
Refer to the timing charts under I/O Circuit Diagrams on page 16 for details.
2
10% max. of sensing distance
E2E-X3D@
3 mm ±10%
0 to 2.4 mm
Iron,
12 × 12 × 1 mm
±10% max. of sensing distance at 23°C in the temperature range of −25 to 70°C
Destruction: 1,000 m/s
Approx. 70 g
Approx. 40 g
Approx. 25 g
Nickel-plated brass
Shielded
M12
E2E-X8MD@
8 mm ±10%
0 to 6.4 mm
Iron,
30 × 30 × 1 mm
0.8 kHz
Unshielded
2
10 times each in X, Y, and Z directions
E2E-X7D@
7 mm ±10%
0 to 5.6 mm
Iron,
18 × 18 × 1 mm Iron, 30 × 30 × 1 mm
0.5 kHz
Approx. 130 g
Approx. 70 g
Approx. 40 g
Shielded
M18
E2E-X14MD@
14 mm ±10%
0 to 11.2 mm
0.4 kHz
Unshielded
E2E-X10D@
10 mm ±10%
0 to 8 mm
Approx. 175 g
Approx. 110 g
Approx. 90 g
Shielded
M30
E2E-X20MD@
20 mm ±10%
0 to 16 mm
Iron,
54 × 54 × 1 mm
0.1 kHz
Unshielded
E2E
8