H7CX-A-N AC100-240 Omron Automation, H7CX-A-N AC100-240 Datasheet - Page 7

no-image

H7CX-A-N AC100-240

Manufacturer Part Number
H7CX-A-N AC100-240
Description
Counter, Digital, Six Digit, Multifunction, 1/16 Din, 100-240VAC, Screw Terminal
Manufacturer
Omron Automation
Type
Counterr
Datasheet

Specifications of H7CX-A-N AC100-240

Brand/series
H7CX
Connection Type
Screw Terminals
Contact Form
3 A at 250VAC/30 VDC
Dimensions
58H x 48W x 98.5D
Display Type
7 Segment LCD
Function
Multifunction Digital Counter
Input Type
Increment, Decrement, Command, Individual and Quadrature
Ip Rating
IP66
Mounting Type
Flush
Number Of Inputs
4
Number Of Outputs
1
Output Type
SPDT
Primary Type
Digital Counter
Voltage, Supply
100-240 VAC
I/O Functions
Using as a Counter
*1. For information on operation of I/O functions, refer to pages page 22 to page 25.
*2. In increment mode or increment/decrement mode, the present value returns to 0; in decrement mode, the present value returns to the set value with 1-stage models,
*3. Reset operates as described in the following table. (The reset indicator will not be lit.)
Operating Procedures (Tachometer Function)
• The following table shows the delay from when the reset signal is input until the output is turned OFF. (Reference values)
Inputs
Outputs
Inputs
Outputs OUT1, OUT2
and returns to set value 2 with 2-stage models.
1-stage/2-stage
preset counter
Total and preset
counter
Batch counter
Dual counter
Twin counter
Minimum reset signal width
Configuration
CP1, CP2
Reset/reset 1
CP1, CP2
Reset/reset 1
Total reset or reset 2
OUT1, OUT2
20 ms
1 ms
Reads counting signals. (The CP2 input can be used when the input mode is not 1-input mode.)
• Holds the measurement value and outputs. (The reset 2 input can be used when the input mode
• The reset indicator is lit when the value is being held.
Outputs signals according to the specified output mode when a set value is reached.
Does not operate (not used).
• Resets the total count value.
• The total count value is held at 0 while the total reset input is ON.
• Resets the batch count value and batch output (OUT1).
• The batch count value is held at 0 while the reset 2 input is ON.
• Resets the CP2 present value.
• Counting for CP2 input cannot be performed while the reset 2 input is ON.
• Resets the CP2 present value.
is 2-input independent measurement.)
*1
(1) In general (except for Dual Counter Mode)
(2) When used as a dual counter or twin counter
(1) In general (except for Dual Counter Mode)
(2) When used as a dual counter or twin counter.
The reset function depends on the selected configuration*3.
Outputs signals according to the specified output mode when a set value is reached.
• Reads counting signals.
• Increment, decrement, command, individual, and quadrature inputs accepted.
• Reads CP1 count signals with CP1 input and CP2 count signals with CP2 input.
• Increment signals can be input.
• Resets present value and outputs (OUT2 when using the batch counter)*2.
• Counting cannot be performed during reset/reset 1 input.
• Reset indicator is lit while reset input is ON.
• Resets the CP1 present value (to 0).
• Counting for CP1 input cannot be performed while the reset 1 input is ON.
• The reset indicator is lit while the reset 1 input is ON.
Output delay time
0.8 to 1.2 ms
15 to 25 ms
Reset operation
H7CX-A@-N
7