AT-FM-2A BANNER ENGINEERING, AT-FM-2A Datasheet - Page 11

no-image

AT-FM-2A

Manufacturer Part Number
AT-FM-2A
Description
Relay; E-Mech; Sfty; Cur-Rtg 4A; Ctrl-V 115/230 AC, 24 DC; Vol-Rtg 250AC/DC
Manufacturer
BANNER ENGINEERING
Datasheet

Specifications of AT-FM-2A

Brand/series
Duo-Touch
Current, Rating
4 A
Function
Safety
Mounting Type
DIN Rail
Power, Rating
1000⁄200 VA⁄W
Relay Type
Electro Mechanical
Voltage, Control
173 VAC
Voltage, Rating
250 VAC/VDC
Coil Voltage Vac Nom
24V
Coil Voltage Vdc Nom
24V
Contact Current Max
4A
Contact Voltage Ac Nom
250V
Contact Voltage Dc Nom
250V
Contact Configuration
SPST-NO
No. Of Poles
1
Lead Free Status / Rohs Status
RoHS Exempt Product
Supply Voltage and Current
Supply Protection Circuitry
Output Configuration
(including Auxiliary N.C.
output 51/52)
Contact Fuse Protection
Output Response Time
Input Requirements
Simultaneity Monitoring
Period
Status Indicators
Housing
Mounting
Vibration Resistance
Operating Conditions
Dimensions
Safety Category
Certifications
Banner Engineering Corp.
www.bannerengineering.com • Tel: 763.544.3164
Minneapolis, MN U.S.A.
DUO-TOUCH
Model AT-AM-2A: 115V ac ± 15% at 100 mA
Model AT-BM-2A: 230V ac ± 15% at 50 mA
Model AT-FM-2A: 24V ac/dc ± 15% at 250 mA
Protected against transient voltages and reverse polarity (dc hookup is without regard to polarity)
Outputs (K1 and K2): two redundant (total of four) safety relay (forced-guided) contacts
NOTE: Transient suppression is recommended when switching inductive loads. Install suppressors across
Auxiliary Monitor Output (K3): One non-safety relay contact
6.3 A quick or 4 A slow
25 milliseconds maximum
Outputs from actuating devices must each be capable of switching 40 to 100 mA @ 12 to 18V dc.
300 milliseconds (typical)
< 500 milliseconds under single-fault conditions
3 green LED indicators (see Figure 1):
Power ON
K1 energized
K2 energized
1 red LED indicator:
Fault
Polycarbonate. Rated NEMA 1 (IEC IP20)
Mounts to standard 35 mm DIN rail track. Safety Module must be installed inside an enclosure rated
NEMA 3 (IEC IP54), or better.
10 to 55Hz @ 0.35 mm displacement per IEC 68-2-6
Temperature: 0° to +50°C (+32° to 122°F)
Maximum Relative Humidity: 90% @ +50°C (non-condensing)
Heat Dissipation Considerations: See page 4.
See Figure 6.
1 and 3 per ISO 13849-1; Type IIIA/B per ISO 13851 (EN574)
(Dependent on hookup and installation of the hand controls)
load. Never install suppressors across output contacts (see Warning on page 8).
LISTED
Contact ratings:
Maximum voltage: 250V ac or 250V dc
Maximum current: 4A ac or dc (resistive load)
Maximum power: 1000 VA, 200 watts
Mechanical life: 10,000,000 operations
Electrical life: 100,000 cycles (typically @ 1.0 kVA switching power)
10Y8
Presence
Sensing
Device
®
Specifications
– Models AT-..M-2A Two-Hand Control Modules
LISTED
Maximum switching voltage: 125V ac or dc
Maximum switching current: 500 mA (resistive load)
P/N 47550 rev. E