VBA10A-T02GN-Z SMC Corporation, VBA10A-T02GN-Z Datasheet - Page 10

no-image

VBA10A-T02GN-Z

Manufacturer Part Number
VBA10A-T02GN-Z
Description
Booster regulator, pressure gauge, silencer, NPTF, ratio 2x, 230 l/min, 1/4 in
Manufacturer
SMC Corporation
Datasheet

Specifications of VBA10A-T02GN-Z

Brand/series
VBA Series
Flow Rate
230 SCFM
Pressure Adjustment
Handle Operating
Pressure Increase Ratio
Twice
Pressure, Operating
1 MPa
Proof Pressure
3.0 MPa
Size, Port
1⁄4 in.
Temperature, Ambient
2 to 50
Thread Type
NPTF
Series
7
1. Warning concerning abnormal outlet pressure
2. Residual pressure measures
1. Check the specifications.
2. Selection
• If there is a likelihood of causing an outlet pressure drop
• Because the outlet pressure could exceed its set range if
• Operate the equipment within its maximum operating
• Connect a 3-port valve to the OUT side of the booster
• After operation is finished, release the supply pressure at
• Consider the operating conditions and operate this product
• Based on the conditions (such as pressure, flow rate, takt
• Use the VBA11A (pressure increase ratio 4) with pressure
• Inlet supply pressure volume is {approximately twice
• When running continuously for longer periods of time,
• Make sure the outlet pressure is set 0.1 MPa or higher than
due to unforeseen circumstances such as equipment
malfunction, thus leading to a major problem, take safety
measures on the system side.
there is a large fluctuation in the inlet pressure, leading to
unexpected accidents, take safety measures against abnor-
mal pressures.
pressure and set pressure range.
regulator if the residual pressure must be released quickly
from the outlet pressure side for maintenance, etc. (Refer to
the diagram below.) The residual outlet pressure side
cannot be released even if the 3-port valve is connected to
the IN side because the check valve in the booster regulator
will activate.
the inlet. This stops the booster regulator from moving
needlessly and prevents operating malfunctions.
within the specification range that is described in this
catalog.
time) required for the outlet side of the booster regulator,
select the size of the booster regulator in accordance with
the selection procedures described in this catalog or model
selection program.
increase ratio 2 to 4. Usage of pressure increase ratio
below 2 is preferred for the VBA10A (pressure increase
ratio 2). A stable operation and increased life expectancy
will result.
(pressure increase ratio 2), approx. 4 times (pressure
increase ratio 4)} the volume of the outlet side. Booster
regulator requires the inlet side volume which is the sum of
the flow volume running into the outlet side and the volume
exhausted from E port (for driving), because air is the power
source.
confirm the life expectancy. The life expectancy of a booster
regulator is dependent upon the operational cycle. Thus,
when used for driving cylinders, etc. in the outlet side, life
expectancy will be reduced.
the inlet pressure. A pressure difference below 0.1 MPa
makes the operation unstable and may result in a malfunc-
tion.
Warning
Caution
VBA
Selection
Design
1. Transporting
2. Installation
1. Flushing
2. Piping size
1. Quality of air source
1. Installation location
• When transporting this product, hold it lengthwise with both
• Install this product so that the silver-colored tie-rods and
• Because the piston cycle vibration is transferred, use the
• If the transmission of vibration is not preferred, insert an
• Mount the pressure gauge with a torque of 7 to 9 N·m.
• Use an air blower to flush the piping to thoroughly remove
• To bring the booster regulator’s ability into full play, make
• Connect a mist separator to the inlet side near the booster
• If dry air (atmospheric pressure dew point: –17°C or less) is
• Do not install this product in an area that is exposed to
• Do not install in locations influenced by vibrations. If it must
hands. Never hold it by the black handle that protrudes from
the center because the handle could become detached
from the body, causing the body to fall and leading to injury.
cover are placed horizontally. If mounted vertically, it may
result in a malfunction.
following mounting bolts (VBA1: M5; VBA2, 4: M10) and
tighten them with the specified torque (VBA1: 3 N·m; VBA2,
4: 24 N·m).
isolating rubber material before installation.
any cutting chips, cutting oil, or debris from the piping
inside, before connecting them. If they enter the inside of
the booster regulator, they could cause the booster regula-
tor to malfunction or its durability could be affected.
sure to match the piping size to the port size.
regulator. If the quality of the compressed air is not
thoroughly controlled, the booster regulator could malfunc-
tion (without being able to boost) or its durability could be
affected.
used, the life expectancy may be shortened because dry air
will accelerate evaporation of grease inside.
rainwater or direct sunlight.
be used in such an area due to unavoidable circumstances,
please contact SMC beforehand.
Caution
Caution
Caution
Caution
Operating Environment
Air Supply
Mounting
Piping