ZSE2-T1-15C SMC Corporation, ZSE2-T1-15C Datasheet - Page 4

no-image

ZSE2-T1-15C

Manufacturer Part Number
ZSE2-T1-15C
Description
Vacuum switch
Manufacturer
SMC Corporation
Datasheet
Atmospheric
pressure 0
Calibration Procedure
Observe the following precautions for setting
the vacuum pressure: Use your fingertips to
gently turn the screwdriver. Do not use a
screwdriver with a large grip or with a tip that
does not fit into the trimmer groove because
this could strip the groove.
Hysteresis
Hysteresis is the pressure difference between
the ON and the OFF pressure of the output
signal. The set pressure is the pressure
selected to switch from OFF to ON condition.
16-6-10
Series
Supply pressure
Set point
Atmospheric
pressure
Set the ON-pressure by the pressure setting
Set the possible min. pressure for adsorption
trimmer. Turning clockwise can set the high
pressure/high vacuum pressure.
confirmation. If setting the pressure lower
than that, switch becomes ON in case that
adsorption is not completely done. If setting
the pressure higher than that, switch does
not become ON even though it may absorb
workpieces.
Regarding the pressure setting
Set point
Indicator light
Caution
setting trimmer
Pressure
0
ZSE2/ISE2
SET
Steady adsorption
Unsteady
adsorption
Non adsorption
ON
OFF
1. Attaching and detaching connectors
How to Use Connector
2. Crimping of lead wires and sockets
Strip 3.2 to 3.7 mm at the end of the lead
wires, insert the ends of core wires evenly into
the sockets, and then crimp with a crimping
tool. When this is done, take care that the
coverings of the lead wires do not enter the
core wire crimping area.
(Crimping tool: model no. DXT170-75-1)
3. Attaching and detaching lead wires
Core wire crimping area
Socket
When assembling the connector to the switch
When removing the connector from the
Attaching
Detaching
housing, push the connector straight onto the
pins until the lever locks into the housing slot.
switch housing, push the lever down to
unlock it from the slot and then withdraw the
connector straight off of the pin.
Insert the sockets into the square holes of
the connector (with +, 0, – indication), and
continue to push the sockets all the way in
until they lock by hooking into the seats in
the connector. (When they are pushed in
their hooks open and they are locked
automatically.) Then confirm that they are
locked by pulling lightly on the lead wires.
To detach a socket from a connector, pull out
the lead wire while pressing the socket’s
hook with a stick having a thin tip (about 1
mm). If the socket will be used again, first
spread the hook outward.
with sockets
Socket
Hook
Hook
Hook
Socket
Lead wire
Hook
Connector
DC polarity indicator
Lever
Pin
Slot
Covering retainer
Housing
Socket
Connector
Lead wire 0.2 to 0.33 mm
DC polarity indicator
Lever
Core wire
0.2 to 0.33 mm
Max. coating O.D.
ø1.7 mm
Max. coating O.D.
ø1.7 mm
Covering
Lead wire
Lead wire
Connector
2
2
-55 PNP
Internal Circuit and Wiring
Example
-15
Connection example with a PLC
at
1. Do not use with thinner, carbon tetrachloride,
2. Operate it away from direct sunlight.
Switch
Refer to pages 16-14-3 to 16-14-4
for
Common Precautions on the
products
catalog, and refer to pages 16-1-
11 to 16-1-13 for Precautions on
every series.
Filter case
– common terminal
chloroform, acetate, aniline, cyclohexane, tri-
chloroethylene, sulfuric acid, lactic acid and
watermiscible cutting fluid (alkaline).
NPN open collector
Caution
Caution
LED Red
LED Red
Safety
open collector
Electric circuit diagram
Electric circuit diagram
mentioned
DC ( + )
Brown
OUT
Black
DC (–)
Blue
OUT
Black
Instructions
DC ( + )
Brown
OUT
Black
DC ( + )
Brown
DC (–)
Blue
DC (–)
Blue
Max. 30 V, 80 mA
Max. 80 mA
Load
12 to 24 VDC
Load
+
+
in
12 to 24 VDC
PLC Input
terminal
COM
+
12 to 24 VDC
and
this

Related parts for ZSE2-T1-15C