9080GM6 TELEMECANIQUE, 9080GM6 Datasheet - Page 2

no-image

9080GM6

Manufacturer Part Number
9080GM6
Description
Terminal Block , 30A, 600VAC, Box Lug, Block Type: Standard
Manufacturer
TELEMECANIQUE
Datasheet
NEMA Style
Terminal Block
Table 24.19: Selection Guide
24-14
Description
Self-Lifting Pressure Wire Connector
for #18 to #12 AWG wire. Mounts
on standard 9080GH track or
35 mm DIN 3 track.
Flat Terminal Connector for
#22 to #12 AWG wire. Screws are
#6-32 x 5/16 in. for ring or spade
lugs, 5/16 in. wide maximum.
Mounts on standard 9080GH
track or 35 mm DIN 3 track.
Fingersafe per DIN 57470.
Circuit Isolating Switchd
with self-lifting pressure
connectors
for #18 to #10 AWG wire.
Mounts on standard 9080GH
track or 35 mm DIN 3 track.
Slip-on Connectors for #22 to
#12 AWG wire. Tabs accept
0.250 x 0.032 in. slip-on connectors
Mounts on standard 9080GH
track or 35 mm DIN 3 track.
Transient Voltage Suppressorsf
with box lug connectors
for #18 to #10 AWG wire.
Mounts on standard 9080GH
track or 35 mm DIN 3 track.
Fuse Block for 13/32 in. Dia. x 1-1⁄ 2
in. ferrule fuse with self-lifting
pressure connectors. Fuse
puller is included as standard.
Fuses are not included.
Mounts on standard 9080GH
track or 35 mm DIN 3 track.
Fingersafe per DIN 57470.
Fuse Pullere
Blown Fuse Indicator/
Pullers are neon pilot
lights which plug on to the
fuse in a standard Type
GF6 fuse block.
a
b
c
d
e
Orders must specify the standard package
quantity or multiples of that quantity.
These maximum current values assume the
use of insulated copper conductors with
75
based on NEC Article 310, Table 310-16. In
most cases this value is the maximum
ampacity of that wire or combination of wires
(as listed in the above table) which has the
greatest current carrying capacity. The
actual allowable current for a particular
application depends on the number, size,
insulation class, and other characteristics of
the wires used. The lower of the UL and CSA
ratings are shown below.
One end-barrier is required for each
assembly of like sections.
Not intended to make or break a live circuit.
Power must be disconnected from the circuit
before operation of the switch.
Fuse puller is supplied as standard with
Class 9080 Type GF6 fuse block. The
9080GH63 is a replacement fuse puller.
o
C temperature rating, and are calculated
Maximum
120–240 V
277–600 V
Voltage
600 V
600 V
600 V
600 V
120 V
600 V
Maximum
Currentb
CP5
40 A
40 A
30 A
20 A
30 A
f
Discount
Schedule
GH63
GLP3
GLP6
Type
Modules have RC circuitry for suppressing
transient voltage, generated when opening a
coil circuit, to approximately 200% of the
peak line voltage, when used with 120 V
coils. Type GT6 is suitable for use with
Square D Class 8501 Type X, K, R and C
relays or Square D Type S starters and
contactors, Sizes 00-2.
GP6
GA6
GG6
GS6
GT6
GF6
Blown Fuse Indicator
Class 9080
Terminal Blocks
$ Price ea.
Blocks
Class
Class
CCN
CCN
File
File
File
File
18.00
20.70
11.70
11.90
11.90
2.60
1.80
4.80
2.40
Packa
/
Std.
E60616
3211 07
E63698
3211 07
XCFR2
025490
025490
Refer to Catalog 9080CT9601
50
50
10
10
10
50
10
10
JDV5
5
GP6B
GP6B
GF6B
GF6B
GT6B
GF6B
Type
End Barriersc
$ Price ea.
N/A
N/A
N/A
Table 24.20: How to Order
For Standard or Custom Assemblies page 24-15
For Mounting Track and Accessories page 24-16
For DIN 3 track and end clamps page 24-12
To Order Specify
1.00
1.00
4.80
4.80
1.70
4.80
1200
900
Class Number
Type Number
600
300
Type G
0
Packa
Std.
10
10
10
10
10
10
Blocks
Without
Transient
Suppression
per ft
N/A
N/A
32
32
16
16
24
16
www.schneider-electric.us
TIME
© 2009 Schneider Electric
Class
9080
Catalog Number
(stranded or solid)
All Rights Reserved
1 or 2 Conductors
1 or 2
1 or 2
1 or 2
1 or 2
Combinations
1–4
1–4
1–2
1–2
1–2
1–2
1–2
1–2
1–2
1–4
1–4
1–4
Copper Wire
1
1
1
1
1
1
1
1
1
Max. Wire
Per Screw
#12–22
N/A
N/A
With Built-in
Transient
Suppression
Type
GP6
#12
#14
#16
#18
#10
#12
#14
#16
#18
#12
#14
#16
#18
#20
#22
#10
#12
#14
#16
#18
#10
#12
#14
#16
#18

Related parts for 9080GM6