CLS-25 Pacific Scientific OECO, CLS-25 Datasheet

no-image

CLS-25

Manufacturer Part Number
CLS-25
Description
Sensor, Current; +/-25A Pri:DC to 200kHz; PCB; 25mA; 1-2-3-4/1000 Turns; +/-0.5%; 1.25
Manufacturer
Pacific Scientific OECO
Type
Hall Effectr
Datasheet

Specifications of CLS-25

Accuracy
± 0.5% @ 25 °C
Brand/series
CLS
Current, Primary
± 25 A (RMS)
Current, Secondary
25 mA
Current, Switching
25 mA
Frequency Response
DC to 200 kHz
Function
Current
Height
4.22 in.
Length
1.25 in.
Mounting Type
PCB
Output
Current
Primary Type
Current
Range, Measurement
50 A
Technology
Hall Effect
Termination
Solder
Turns Ratio
1-2-3-4⁄1000
Voltage, Supply
15 VDC
Width
0.071 in.
Lead Free Status / Rohs Status
RoHS Compliant part
For Use With
Variable speed drive for motors, welding equipment, power supply equipment, measure and control system
This closed loop current sensor provides excellent performance at affordable prices.
Accuracy at +25
General Information
the primary (high current) and secondary circuits. It has four integral primary pins.
Nominal Current (I
Measuring Range
Measuring Resistance .............................................................................. R min.
Nominal Analog Output Current ................................................................ 25 mA
Turns Ratio.............................................................................................. 1-2-3-4/1000
Supply Voltage ....................................................................................... ±15 Vdc (+5%)
Galvanic Isolation .................................................................................... 5 kV RMS/50 Hz/1 minute
Zero Offset Current at + 25
Thermal Drift of offset Current O
Linearity ................................................................................................. better than ±0.2%
Response Time ....................................................................................... less than 1 ms
Bandwidth............................................................................................... DC to 200 kHz (-1dB)
Operating/Storage Temperature ............................................................... -40
Current Consumption ............................................................................... 10 mA plus output current
Secondary Internal Resistance (at + 70
Primary Internal Resistance ..................................................................... <1.25 milliohm per turn
Weight ................................................................................................... 17 g maximum
Package ................................................................................................. Insulated plastic case (UL94-VO)
Mounting ................................................................................................ Designed to mount directly on PCB via
Output Reference .................................................................................... To obtain a positive output on the terminal marked
[1] = The CLS-25 offers a choice of 4 measuring ranges (refer to the mechanical dimensions on the following page)
[2] = For 2 seconds only
[3] = Excludes the effect of zero offset
[4] = Over the operating range ±50 A.t.
Description
The CLS-25 is a reduced size current transducer based on the principle of
magnetic compensation. It provides electronic measurement of DC, AC
or pulsed currents, and their combinations, with galvanic isolation between
Features
• Noncontact measurement of high current
• Measures DC, AC and impulse currents
• Current sensing up to 400A peak
• Very fast response and high accuracy
• High overload capacity
Electrical Specifications
Notes:
Model CLS-25
• PC board mount
o
[1]
C
N
[3][4]
) ................................................................................ 25 A.t RMS
.................................................................................. 0 to ± 50 A.t (± 62 A.t)
with ±15V at ±25 A.t Max. ...................................... 54 ohm
............................................................................ 0.5% of I
o
C ............................................................... better than ±0.15mA
o
C to 70
at ±50 A.t Max. ...................................... 54 ohm
at ±90 A.t Max. ...................................... 54 ohm
o
C) ............................................... 66 ohm
o
C ............................................... better than ±0.6mA
Applications
• Variable speed drives for motors
• Welding Equipment
• Power supply Equipment
• Measure and control system
• Over current protection
• Protection of power semiconductors
Closed Loop Hall Effect
hole connection pins.
“O”, current must flow from terminals 1,2,3,4 to
terminals 8,7,6, and 5 (conventional flow).
CLS-25
o
C to + 85
N
Max.
R max.
360 ohm
150 ohm
54 ohm
o
C/-40
o
C to + 90
[2]
o
C

Related parts for CLS-25

CLS-25 Summary of contents

Page 1

... Mounting ................................................................................................ Designed to mount directly on PCB via Output Reference .................................................................................... To obtain a positive output on the terminal marked Notes: [1] = The CLS-25 offers a choice of 4 measuring ranges (refer to the mechanical dimensions on the following page) [2] = For 2 seconds only [3] = Excludes the effect of zero offset [4] = Over the operating range ±50 A.t. ...

Page 2

... Mechanical Dimensions All dimensions are in inches (millimeters) Model CLS-25 1.25 (31.75 CLS-25 0.80 (20.30 ) 0.020 (0.5 ) DIRECTION OF CURRENT PIN PIN 1 0.272 (6.90 ) 0.1 14 (2.9 ) 0.305 (7.75) 0.100 (2.54) Primary Primary Nominal Output Primary Current Current Current (mA) Turns NOM. I MAX Notes: 1. Mounting Holes - Primary Pins 0.057 (1.45) 2 ...

Related keywords