IL410 Vishay / Small Signal & Opto Products (SSP), IL410 Datasheet - Page 7

no-image

IL410

Manufacturer Part Number
IL410
Description
Optoisolator; Analog; 6-Pin DIP; TRIAC; 1.16 V; 60mA; 500 mW; 6 V
Manufacturer
Vishay / Small Signal & Opto Products (SSP)
Type
Analogr
Datasheet

Specifications of IL410

Capacitance
25 pF
Current, Forward
60 mA
Input Type
LED
Output Type
Triac
Package Type
6-Pin DIP
Power Dissipation
500 mW
Special Features
Zero Crossing
Temperature, Operating, Maximum
150 °C
Temperature, Operating, Minimum
-55 °C
Time, Turn-off
50 μs
Time, Turn-on
35 μs
Voltage, Forward
1.16 V (Typ.)
Voltage, Reverse
6 V
Lead Free Status / Rohs Status
RoHS Compliant part Electrostatic Device

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
IL410
Manufacturer:
INFINEON
Quantity:
2 700
Part Number:
IL410
Manufacturer:
VISHAY/威世
Quantity:
20 000
Part Number:
IL410-X001
Manufacturer:
SIEMENS/西门子
Quantity:
20 000
Company:
Part Number:
IL410-X001
Quantity:
70 000
Company:
Part Number:
IL410-X007
Quantity:
70 000
Part Number:
IL410-X007T
Manufacturer:
VISHAY
Quantity:
5 621
Part Number:
IL410-X009T
Manufacturer:
VISHAY/威世
Quantity:
20 000
Company:
Part Number:
IL410-X009T
Quantity:
70 000
Company:
Part Number:
IL410-X019T
Quantity:
70 000
Part Number:
IL41050TA-3E
Manufacturer:
DELTA
Quantity:
1 000
Part Number:
IL41050TAE
Manufacturer:
NVE
Quantity:
20 000
Part Number:
IL41050TE
Manufacturer:
NVE
Quantity:
100
Part Number:
IL4106
Manufacturer:
INFINEON
Quantity:
5 510
Part Number:
IL4108
Manufacturer:
INFINEON/英飞凌
Quantity:
20 000
Company:
Part Number:
IL4108
Quantity:
9 600
Technical Information
Commutating Behavior
The use of a triac at the output creates difficulties in
commutation due to both the built-in coupled thyristor
systems. The triac can remain conducting by parasitic
triggering after turning off the control current. How-
ever, if the IL410/4108 is equipped with two separate
thyristor chips featuring high dv/dt strength, no RC cir-
cuit is needed in case of commutation.
Current commutation:
The values 100 A/ms with following peak reverse
recovery current > 80 mA should not be exceeded.
Avoiding high-frequency turn-off current
oscillations:
This effect can occur when switching a circuit. Current
oscillations which appear essentially with inductive
loads of a higher winding capacity result in current
commutation and can generate a relatively high peak
reverse recovery current. The following alternating
protective measures are recommended for the indi-
vidual operating states:
Document Number 83627
Rev. 1.4, 26-Apr-04
iil410_12
Figure 12. Typical Static Inhibit Voltage Limit
V
parameter: T
Device zero voltage
switch can be triggered
only in hatched area
below Tj curves.
DINHmin
=f(I
F
j
/I
FT
25°C),
Figure 13. 1- Apply a Capacitor to the Supply Pins at the Load-Side
Figure 14. 2 - Connect a Series Resistor to the Output and Bridge
Note: Measures 2 to 3 are especially required for the load sepa-
rated from the IL410/ IL4108 during operation. The above men-
tioned effects do not occur with IL410/ IL4108 circuits which are
Figure 15. 3 - Connect a Choke of Low Winding Cap. in Series,
iil410_14
iil410_15
iil410_13
1
2
3
1
2
3
1
2
3
e.g., a Ringcore Choke, with Higher Load Currents
6
5
4
Both by a Capacitor
6
5
4
6
5
4
Vishay Semiconductors
500 µH
IL410/ IL4108
33 Ω
22 nF
22 nF
0.1 µF
www.vishay.com
220 V~
220 V~
220 V~
7