511 Staco Energy Products Co., 511 Datasheet - Page 2

no-image

511

Manufacturer Part Number
511
Description
Transformer, Var.; 0 to 120V Vo; 5A Io; 0.60kVA; 120V Vi; Panel; 50/60Hz; CW/CCW
Manufacturer
Staco Energy Products Co.
Type
Variabler
Datasheet

Specifications of 511

Brand/series
500 Series
Capacity
0.60 kVA (Max.)
Configuration
Open Frame
Current, Secondary
5 A
Dimensions
4.16"L×2.38"W×3.94"H
Frequency
50/60 Hz
Mounting Hole Centers
3.12 "
Mounting Type
Panel/Chassis
Number Of Outlets
1
Phase
1
Power, Rating
0.6/0.7 kVA (Constant Current Load), 0.84 kVA (Constant Impedance Load)
Termination
Solder Lug/Quick-Connect
Voltage, Primary
120 VAC
Voltage, Secondary
0-120/0-140 VAC
Weight
4.5 lbs.
Lead Free Status / Rohs Status
RoHS Compliant part

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
511-038
Manufacturer:
BIV
Quantity:
1 000
Part Number:
5110-1M
Manufacturer:
NS/国半
Quantity:
20 000
Part Number:
5110-4206
Manufacturer:
MOLEX
Quantity:
924
Part Number:
5110-B7A2PL
Manufacturer:
3M
Quantity:
543
Part Number:
5110.0133.1
Manufacturer:
N/A
Quantity:
48 474
Part Number:
5110.0133.1
Manufacturer:
SMD
Quantity:
35 000
Part Number:
51100
Manufacturer:
TI/德州仪器
Quantity:
20 000
++ Line to line voltage
M501C-2+
M501C-3+
3PN501B
PART NO.
M501C+
501C-2
501C-3
500 Series
Versatility, compactness and durability are included in the many
designed-in features of the STACO 501C Series Variable
Transformers. These transformers operate from 120 volt input
lines and are rated at 5 amperes for constant current loads and 7
amperes for constant impedance loads at line voltage. The coil
tapping arrangement permits output voltage of 0 to line voltage or
17% above line voltage on constant current line conditions. This
unit’s Faston
with the terminal adapter kits supplied with each unit.
The STACO 511 is ideal for OEM applications with its panel
mount, fixed shaft design and even smaller envelope than the
501C
511
Unit is fused for the constant current rating at the factory.
Jumper provided in the standard common position and should be moved or
removed as required.
WIRING
Single
Phase
Three
Phase
Series
Phase
Deltaπ
Phase
Phase
Phase
Single
Single
Single
Open
Three
Wyeπ
®
terminals are easily converted to screw connections
VOLTS
120
240
120
240
120
120
++
++
INPUT
HERTZ
50/60
50/60
50/60
50/60
50/60
50/60
60
VOLTS
0-120
0-140
0-240
0-280
0-120
0-140
0-240
0-280
0-140
0-120
0-140
5.0 ‡
AMPS
MAX
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
CONSTANT
CURRENT
LOAD
511
OUTPUT
0.60
0.70
1.04
1-21
2.08
2.43
0.70
0.60
0.70
MAX
KVA
1.2
1.4
AMPS
MAX
7.0
7.0
7.0
7.0
7.0
IMPEDANCE
CONSTANT
LOAD
π
+
501C. it can be single point or four point mounted. The four point
mounting is the same as the 501-C.
Either unit can be operated from 50-2000 hertz without derating.
Motor driven units are available and identified by the prefix “M” in
the type number. The synchronous motor is designed for opera-
tion on 120 volt, 50/60 Hertz single phase lines and draws
approximately 0.3 amperes. If a motor driven model is ordered,
be sure to prefix the part number with the desired travel time from
0 to maximum of 5, 15, 30, or 60 seconds.
MAX
KVA
0.84
1.68
1.46
2.91
0.84
If ganged units are used in a system that ordinarily has a common neutral or
ground between source and load, the neutral or ground must be connected to
the common terminals of the variable transformer assembly. If the system has no
neutral, the load must be balanced or the transformers will be damaged.
Motor driven units use terminal connections for CCW increasing voltage as viewed
from the base end. See figure 23 on page 9 for motor wiring.
INCREASE
ROTATION
VOLTAGE
SHAFT
CCW
CCW
CCW
CCW
CCW
CCW
CCW
CCW
CCW
FOR
CW
CW
CW
CW
CW
CW
CW
CW
CW
CW
LINE CORD & RECEPTACLE
1-4-1
4-1-4
5-4-5
2-1-2
1-1-1
4-4-4
5-5-5
2-2-2
TERMINAL CONNECTIONS
Input
2-2
1-4
1-4
4-5
1-2
1-1
4-4
5-5
1-4
4-2
As Viewed from Base End
(For increasing Voltage)
Jumper• Output
1-1-1
1-1-1
4-4-4
4-4-4
1-1
4-4
1-1
4-4
4-4
1-1
4-4
1-1
3-4-3
3-1-3
3-4-3
3-1-3
3-3-3
3-3-3
3-3-3
3-3-3
3-3
4-3
1-3
4-3
1-3
3-3
3-3
3-3
4-3
4-4
(Pg 8 & 9)
SCHE-
MATIC
10 & 4
10 & 5
10 & 6
10
3
8
11 1/2
15 1/2
5 1/4
7 3/4
4 1/2
LBS. DRIVEN
5M501C
NET
WT.
MOTOR
(Max)
12
20
26

Related parts for 511