18D-2-30I Payne Controls Company, 18D-2-30I Datasheet - Page 2

no-image

18D-2-30I

Manufacturer Part Number
18D-2-30I
Description
Controller, Phase; Single Phase; 7.2; 240 VAC; 30 A; 0 to 238 VAC; 50/60 Hz
Manufacturer
Payne Controls Company
Type
Phase Angler
Datasheet

Specifications of 18D-2-30I

Brand/series
18D Series
Capacity
7.2 kVA
Connection Type
Single Phase
Current, Output
30 A
Dimensions
3.5"W×6.25"H×4.1"D
Frequency, Operating
50⁄60 Hz
Power, Rating
7.2 kVA
Primary Type
Controller
Voltage, Input
240 VAC
Voltage, Output
0 to 238 VAC
Voltage, Supply
240 VAC
ENGINEERING
18D OPTION NOTES:
1.
2.
3.
CURRENT LIMIT
VOLTAGE LIMIT
TEMPERATURE
277 VAC INPUT
550 VAC INPUT
600 VAC INPUT
THERMISTOR
REGULATION
SOFT START
To order, specify option number seperately, and add
option price to control list price.
See page 46 for detailed option description.
Options must be ordered with control
(except Option 20)
OVERTEMP
OPTICALLY
EXTERNAL
120V PILOT
EXTERNAL
CONTROL
RETROFIT
HEATSINK
CONTROL
ISOLATED
CONTROL
ISOLATED
MILLIAMP
VOLTAGE
OPTION
CHASSIS
70-400Hz
SWITCH
POWER
NAME
CARD
ma.
18D-3-etc.
18D-5-etc.
18D-6-etc.
OPTION
ORDER
No.
11C
11D
11G
11H
14B
15B
20B
20C
20D
20E
20H
24B
11A
11B
11E
11F
14A
15A
20A
24A
12
13
19
22
28
30
33
9
RMS Output Voltage Limit (Field adjustable)
closed-loop apps only
1-5 ma., ≤1000 Ω
2-10ma., ≤1000 Ω
4-20 ma., ≤600 Ω
12-20 ma., ≤600 Ω
10-50 ma., ≤300 Ω
1-5 volts DC
2-10 volts DC
Other. Specify ma. range and input impedance.
RMS Output Current Limit (Field Adjustable, includes current transformer)
RMS Output Voltage Regulation.
± 1 % output variation with ± 10% input voltage variation
For installation in non-vented enclosures.
Electrically Isolated Chassis, 10-30A, 480 VAC only. (Std. on 10-30A, 120/240 VAC)
Electrically Isolated Chassis, 50-80A
Thermistor Bridge, Proportional, Automatic Temperature Control.
Temperature Range 0-90
Temperature Range 90-240
1/2 second voltage ramp, to reduce inrush current.
Optically isolated. May be field installed. Suitable for open-loop control.
1-5 ma., ≤1000 Ω
2-10ma., ≤1000 Ω
4-20 ma., ≤600 Ω
12-20 ma., ≤600 Ω
10-50 ma., ≤300 Ω
Other.
To physically replace units built prior to 8/90.
120, 240 VAC, 10-30 Amps only
Overtemp trip of controller.
For external indicating circuit or alarm.
120 VAC On/Off Pilot Control
For operation on power frequencies from 70-400Hz, and 16-2/3 or 25Hz.
External trigger circuit power. Specify voltage to be supplied.
Rated for 277 VAC Input.
(Change Model No. from 18D-4-etc. to 18D-3-etc.)
Rated for 550 VAC Input.
(Change Model No. from 18D-4-etc. to 18D-5-etc.)
Rated for 600 VAC Input. (May require size increase of base model.)
(Change Model No. from 18D-4-etc. to 18D-6-etc.)
Specify ma. range and input impedance.
o
option
21A
21B
21C
21D
21E
C
o
C
DESCRIPTION
Optically-isolated input. open- or closed-loop apps.
1-5 ma., ≤1000 Ω
2-10 ma., ≤1000 Ω
4-20 ma., ≤600 Ω
12-20 ma., ≤600 Ω
10-50 ma., ≤300 Ω
4.
5.
OPTION
Certain combinations of options may not be
compatible. See page 47 or consult local
representative or factory.
Consult factory for option requirements not shown.
CONTROL OPTIONS
Model
Page 15