CSE2425 Crydom Company, CSE2425 Datasheet - Page 3

no-image

CSE2425

Manufacturer Part Number
CSE2425
Description
Relay; SSR; Zero-Switching; Cur-Rtg 25A; Ctrl-V 15-32DC; Vol-Rtg 24-280AC; Pnl-Mnt
Manufacturer
Crydom Company
Datasheet

Specifications of CSE2425

Brand/series
CS Series
Current, Leakage, Off-state
1.0 mA (Max.)
Current, Rating
25 A
Current, Surge
250 Apeak @ 16.6 ms
Dielectric Strength
4000 V (RMS) @ 50⁄60 Hz
Dimensions
1.80 in. L x 0.90 in. W x 2.30 in. H
Function
Zero-Switching
Impedance, Input
2000 Ohms (Nom.)
Mounting Type
Panel
Number Of Pins
4
Relay Type
Solid State
Resistance, Thermal, Junction To Case
1.02 °C⁄W
Standards
UL, CSA, VDE, CE
Temperature, Ambient, Maximum
+80 °C
Temperature, Ambient, Minimum
-40 °C
Termination
Saddle Clamp
Transient Overvoltage
600 Vpeak
Voltage, Control
32 VDC
Voltage, Rating
280 VAC
Lead Free Status / Rohs Status
RoHS Compliant part

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
CSE2425-4626
Manufacturer:
NULL
Quantity:
26
Part Number:
CSE2425-4626
Manufacturer:
VICOR
Quantity:
334
G E N E R A L N O T E S
OUTPUT SPECIFICATIONS ➀
Operating Voltage (47-63 Hz) [Vrms]
Load Current Range
Transient Overvoltage [Vpk]
Max. Surge Current, (16.6ms) [Apk]
Max. On-State Voltage Drop @ Rated Current [Vpk]
Thermal Resistance Junction to Case (R
Maximum I 2 t for Fusing, (8.3 msec.) [A 2 sec]
Max. Off-State Leakage Current @ Rated Voltage [mA]
Min. Off-State dv/dt @ Max. Rated Voltage [V/µsec]
Max. Turn-On Time
Max. Turn-Off Time
Power Factor (Min.) with Max. Load
INPUT SPECIFICATIONS
Control Voltage Range
Max. Turn-On Voltage
Min. Turn-Off Voltage
Nominal Input Impedence
Typical Input Current
SERIES CS.
Rev. 010405
PAGE 1 OF 3
Turn-on time for random turn-on version (-10 suffix) is 0.1ms
All parameters at 25ºC unless otherwise specified.
Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1
Heat sinking required, for derating curves see page 2.
[Arms]
M O D E L N U M B E R S
➀ ➀
θJC
) [˚C/W]
• Low Leakage
• SCR Output
• Panel Mount
• Zero and Random
• Internal Overvoltage
• • •
Voltage Switching
Protection Available
CSD2410
CSE2410
1/2 Cycle
1/2 Cycle
0.15-10
24-280
1.48
600
120
500
1.6
1.0
0.5
60
DC CONTROL
15 mA @ 5 Vdc
(CSD PREFIX)
3.5-15 Vdc
300 Ohm
3.5 Vdc
1.0 Vdc
CSD2425
CSE2425
1/2 Cycle
1/2 Cycle
0.15-25
24-280
© 2005 CRYDOM CORP, Specifications subject to change without notice.
1.02
600
250
260
500
1.6
1.0
0.5
10-90A
CSD2450
CSE2450
1/2 Cycle
1/2 Cycle
0.15-50
24-280
1620
The Series CS has an SCR AC switch
output featuring low off-state leakage
(1mA, snubberless), zero and random
voltage switching and a broadened
operating range (24-280Vac).
This wide range permits optimum
performance at both120Vac and
240Vac line voltages.
Manufactured in Crydom’s ISO 9001
Certified facility for optimum product
performance and reliability.
0.63
600
625
500
1.6
1.0
0.5
mp
• 120/240 V
CSD2475
1/2 Cycle
1/2 Cycle
S
CSE2475
0.25-75
24-280
DC CONTROL
1000
4150
0.31
600
500
1.6
1.0
0.5
eries
7mA @ 15 V
(CSE PREFIX)
15-32 Vdc
15.0 Vdc
2k Ohm
1.0 Vdc
ac
• AC OUTPUT
CSD2490
1/2 Cycle
1/2 Cycle
CSE2490
0.25-90
24-280
CS
1200
6000
0.28
600
500
1.6
1.0
0.5

Related parts for CSE2425