SMART 3000NET Tripp Lite, SMART 3000NET Datasheet - Page 3

no-image

SMART 3000NET

Manufacturer Part Number
SMART 3000NET
Description
UPS, 3000VA, OOutlets: 8 four 15-amp & four 20-amp
Manufacturer
Tripp Lite
Type
Home/Office, Networkr
Datasheets

Specifications of SMART 3000NET

Brand/series
SmartPro®
Capacity
3000 VA
Color
Gray
Communication
DB9, RS232
Dimensions
43.2cmH×22.9cmW×31.75cmD
Input Type
NEMA L5-30P
Length, Cord
8 ft.
Mounting Type
Rack/Tower
Operation
Line-Interactive
Output Type
(4) NEMA 5-15R, (4) NEMA 5-15/20R
Power, Rating
2400 W
Time, Backup
7 min.
Voltage, Input
120 V
Voltage, Output
120 VAC
Voltage, Supply
2400/3000 W/VA
Weight
40.4 kg
Power Rating
3000 VA
Output Voltage Rating
120 V
Number Of Outlets
10
Interface Port
DB9 / Contact Closure
Runtime (full Load)
7 min
Runtime (half Load)
23 min
Topology
Line Interactive
Tower / Rackmount
Tower
Lead Free Status / Rohs Status
RoHS Compliant part
UPS input connection
type
UPS Input cord length
(ft.)
UPS Input cord length
(m)
Recommended
Electrical Service
Input cord length (ft.)
Input cord length (m)
BATTERY
Full load runtime
(minutes)
Half load runtime
(minutes)
Expandable battery
runtime
External battery pack
compatibility
DC system voltage
(VDC)
Battery recharge rate
(included batteries)
VOLTAGE REGULATION
Voltage regulation
description
Overvoltage correction
Undervoltage correction
Severe undervoltage
correction
LEDS ALARMS & SWITCHES
LED Indicators
Alarms
Alarm cancel operation
Switches
SURGE / NOISE SUPPRESSION
UPS AC suppression
joule rating
UPS AC suppression
response time
EMI / RFI AC noise
suppression
PHYSICAL
L5-30P
8
2.4
30A 120V
8
2.4
7 min. (2400w)
23 min. (1200w)
Extended runtime supported via optional external battery packs
BP24V28-2U
24
Less than 9 hours from 10% to 90%
Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 87 to 140
Input voltages between 127 and 140 are reduced by 12%
Input voltages between 95 and 105 are boosted by 10%
Input voltages between 87 and 94 are boosted by 22%
5 LEDs indicate line power, battery power, overload, voltage regulation and battery low/replace status
Audible alarm indicates power-failure and low-battery conditions
Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate
low-battery status
2 Switches control off/on power status and alarm-cancel/self-test operation; set of 4 rear-panel switches control
system enable and contact closure port inverter shutoff commands
480
Instantaneous
Yes
(limit 1);
BP24V70-3U
(multi-pack compatible)