FLUKE-717 3000G Fluke, FLUKE-717 3000G Datasheet

no-image

FLUKE-717 3000G

Manufacturer Part Number
FLUKE-717 3000G
Description
PRESSURE CALIBRATOR 3000 PSIG
Manufacturer
Fluke
Type
Pressurer
Datasheet

Specifications of FLUKE-717 3000G

Lead Free Status / Rohs Status
RoHS Exempt Product
Fluke 718 Pressure Calibrator
The complete solution to pressure calibration
The Fluke 718 pressure calibrator family (4 models)
provide a total pressure calibration solution for
transmitters, gauges and switches. This compact
pressure calibration solution is about a third of the
size of comparable instruments and weighs just one
kilogram (two pounds). The unique, easy to clean
out access ports built into the pump protect the
pump from fluids and provides the ability to service
the pump without disassembly.
General Specifications
Maximum voltage: 30 volts: Non-operating
Temperature: -40 °C to 60 °C
Operating temperature: -10 °C to 55° C
Relative humidity: 95 % (10 °C to 30 °C); 75 % (30 °C to 40 °C);
45 % (40 °C to 50 °C); 35 % (50 °C to 55 °C)
Operating altitude: 3,000 m max
Shock: 1 m drop test
Vibration: Random, 2 g, 5 Hz – 500 Hz
Safety: CSA C22.2 No. 1010.1: 1992
EMC: EN50082-1: 1992 and EN55022: 1994 Class B
Size/weight (717 with holster): 201 mm x 98 mm x 52 mm
(7.93 in x 3.86 in x 2.06 in) 600 g (21 oz)
Size/weight (718 with holster): 216 mm x 94 mm x 66 mm
(8.50 in x 3.72 in x 2.60 in) 992 g (35 oz)
Power: 9V battery ANSI/NEDA 1604A or IEC 6LR619V alkaline; two
batteries in 718
Battery Life: 4 to 20 hours typical, depending on functions used
Warranty: Three years (one year on pressure pump in Fluke 718)
Display: LCD, 5 digit pressure and current simultaneous
Accuracy: 0.05 %
Note: For use with non-corrosive gasses
Fluke Pressure
Pressure Source and Milliamp Measurement to
calibrate and maintain almost any pressure device
Integrated pump is easily cleaned when
accidentally exposed to fluids:
– reduces cost of ownership and repairs
– service the pump in the field
Error % calculation for quicker pass/fail decision
making in the field
Best in class mA accuracy of 0.015 % for better
measurement confidence and workload coverage
Min/Max/Hold to capture changing measurements
Switch test feature for quicker and more accurate
pressure switch testing
New 1 and 300 PSI pressure ranges mean fewer
extra tools required
1, 30, 100 & 300 PSI ranges now available
Calibrators
Technical Data

FLUKE-717 3000G Summary of contents

Page 1

... Power: 9V battery ANSI/NEDA 1604A or IEC 6LR619V alkaline; two batteries in 718 Battery Life hours typical, depending on functions used Warranty: Three years (one year on pressure pump in Fluke 718) Display: LCD, 5 digit pressure and current simultaneous Accuracy: 0.05 % Note: For use with non-corrosive gasses ...

Page 2

... The New 718 Calibrator Pump The new Fluke 718 is a uniquely protected pneu- matic pressure calibrator and pump. The new pump design uses protective check valves that allow air to pass through the pump for calibration but inhibits fluids from entering the pump and causing damage. ...

Page 3

... Functions: Fluke 718 series via built in pump Range: Loop Power: Measure Accuracy: Fluke 717 Series via pressure module connector using optional Pressure Modules Range: Resolution: Accuracy: Functions: For additional detail on the 718, see the application note "Pressure calibration with the 718." ...