AR10-M5H-1 SMC Corporation, AR10-M5H-1 Datasheet

no-image

AR10-M5H-1

Manufacturer Part Number
AR10-M5H-1
Description
AIR REGULATOR, M5 PORT, PANEL MT W/SET NUT, .02-.2MPA SETTING, PSI, F
Manufacturer
SMC Corporation
Datasheet
Regulator
Series
Regulator with Backflow Mechanism
Series
Page 41 through to 49
Page 41 through to 49
AR
AR„K
Modular Type
Regulators
Series
AR10
AR20
AR25
AR30
AR40
AR40-06
AR50
AR60
AR20K
AR25K
AR30K
AR40K
AR40K-06
AR50K
AR60K
AR
Model
1/4, 3/8, 1/2
1/4, 3/8, 1/2
Port size
M5 x 0.8
1/8, 1/4
1/4, 3/8
1/4, 3/8
1/8, 1/4
1/4, 3/8
1/4, 3/8
3/4, 1
3/4, 1
3/4
3/4
1
1
Bracket
Square embedded type
pressure gauge
(except for the AR10)
Digital pressure switch
(except for the AR10)
Round type pressure gauge
Panel mount
Option
40

Related parts for AR10-M5H-1

AR10-M5H-1 Summary of contents

Page 1

... AR25K 1/4, 3/8 AR30K 1/4, 3/8 AR40K 1/4, 3/8, 1/2 AR40K-06 3/4 AR50K 3/4, 1 AR60K 1 Option Bracket Square embedded type pressure gauge (except for the AR10) Digital pressure switch (except for the AR10) Round type pressure gauge Panel mount 40 ...

Page 2

... Regulator AR10 to AR60 Regulator with Backflow Mechanism AR20K to AR60K With the backflow function it incorporates a mechanism to exhaust the air pressure in the outlet side reliably and quickly. Example 1) When the pressure in the rear and the front of the cylinder differs Symbol Nil With backflow ...

Page 3

... ZA Note 7) Digital pressure switch: With unit switching function Note 1) The AR10 comes with a backflow mechanism as a standard feature not available.) When using the AR10 type as w/ backflow mechanism, back flow may not occur with the set pressure 0.15 MPa or less. Note 2) Option B, G and H are not assembled and are supplied loose at the time of shipment ...

Page 4

... The pressure gauge included with regulators for 0.02 to 0.2 MPa setting is for up to 0.2 MPa use only (except for the AR10). Exceeding 0.2 MPa of pressure can damage the gauge not use tools on the pressure regulator knob as this may cause damage. It must be operated manually. ...

Page 5

... Flow rate ( /min (ANR)) AR40(K)-06 Rc 3/4 0.6 0.5 0.4 0.3 0.2 0 1000 2000 3000 4000 5000 Flow rate ( l /min (ANR)) AR10 AR60 to AR20K AR60K to Condition: Inlet pressure 0.7 MPa AR50(K) 0.6 0.5 0.4 0.3 0.2 0 5000 l Flow rate ( /min (ANR)) AR60(K) 0 ...

Page 6

... AR10 AR60 to Series AR20K to Series Pressure Characteristics (Representative values) AR10 0.3 Set point 0.25 0.2 0. 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 Inlet pressure (MPa) AR20(K) 0.25 Set point 0.2 0. 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 Inlet pressure (MPa) AR25(K) 0 ...

Page 7

... Check valve assembly Note 1) The AR10 is a piston type. Assembly of a piston and a seal (KSYP-13). Note 2) Check valve assembly is applicable for a regulator with backflow mechanism (the AR20K to AR60K) only. Assembly of a check valve cover, check valve body assembly and 2 screws ...

Page 8

... Series AR20K to Series Working Principle (Regulator with Backflow Mechanism) AR10 IN (Inlet pressure) Figure 1 When the inlet pressure is higher than the regulating pressure, the check valve operates as a normal regulator (Figure 1). When the inlet pressure is shut off and exhausted, any inlet pressure applied to the valve q will be lost. The force for seating the valve q is the valve spring force w only ...

Page 9

... AR10 to Series AR20K AR60K Panel fitting dimension (Port size AR10, AR20(K) to AR30(K): Max. 3.5 AR40(K): Max Bracket (Option (Port size Bracket M (Option) Optional specifications Square type Digital pressure gauge pressure gauge — — ...

Page 10

Air Filter AR20 to AR60 Made to Order Please contact SMC for detailed dimensions, specifications, and lead times. q Special Temperature Environment Special materials are used in the manufacturing of seals and resin parts to allow them to withstand various ...

Page 11

Options Digital Pressure Switch ISE35 Symbol N Wiring bottom entry Lead wire entry R Wiring top entry + 25 NPN output Output 65 PNP output + Note 2) Nil With unit switching function M Note ...

Page 12

Series Safety Instructions These safety instructions are intended to prevent a hazardous situation and/or equipment damage. These instructions indicate the level of potential hazard by labels of "Caution", "Warning" or "Danger". To ensure safety, be sure to observe ISO 4414 ...

Page 13

... Akihabara UDX 15F, 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021, JAPAN Phone: 03-5207-8249 FAX: 03-5298-5362 URL http://www.smcworld.com © 2006 SMC Corporation All Rights Reserved Specifications are subject to change without prior notice and any obligation on the part of the manufacturer. NORWAY SMC Pneumatics Norway A/S POLAND SMC Industrial Automation Polska Sp ...

Page 14

Pilot Operated Regulator Series Standard Specifications AR425 Model 1/4, 3/8, 1/2 Port size Fluid Proof pressure Max. operating pressure (1) 0.05 to 0.83 0.02 to 0.2 0.05 to 0.83 0.02 to 0.2 0.05 to 0.83 0.02 to 0.2 0.05 to ...

Page 15

AR425 to 935 Series Flow Characteristics AR425 Flow rate ( /min (ANR)) l AR625 Flow rate ( /min (ANR)) l AR825 Flow rate ( /min (ANR)) l AR925 Flow rate ( /min (ANR)) l 14-4-16 Inlet pressure: 0.7 MPa AR435 ...

Page 16

Construction Relief port Bleed port Handle locking screw Component Parts No. Description q Body w Bonnet e Chamber r Valve guide ∗ In the case of AR825/835/925/935, the material is aluminum alloy. Replacement Parts No. Description Material AR425, 435 t!1 ...

Page 17

Specialty Regulators ...

Page 18

NAR Series Flow and Pressure Characteristics NAR425, 435, 625, 635, 825, 835, 925, 935 Flow characteristics Condition: Supply pressure 100 psig NAR425 NPT 1/2 101.5 87 72 70.6 141.3 212 Flow (SCFM) NAR625 101.5 ...

Page 19

Specialty Regulators Construction No. Name Material Exhaust valve assembly 5 6 Main valve diaphragm assembly Valve assembly 7 8 Regulating spring SWPB Valve spring SUS304 9 Pilot Diaphragm 11 Repair Kit Dimensions Model 3.15 5.55 1.46 NAR425•435 ...