BTM7752G Infineon Technologies, BTM7752G Datasheet - Page 19

Motor / Motion / Ignition Controllers & Drivers Hi Current H-Bridge Trilith IC 3G

BTM7752G

Manufacturer Part Number
BTM7752G
Description
Motor / Motion / Ignition Controllers & Drivers Hi Current H-Bridge Trilith IC 3G
Manufacturer
Infineon Technologies
Type
H-Bridge Motor Driverr
Datasheet

Specifications of BTM7752G

Product
Electronic Ignition Drivers
Operating Supply Voltage
45 V
Supply Current
5 mA
Mounting Style
SMD/SMT
Package / Case
PG-DSO-36
Supply Voltage (min)
- 0.3 V
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
BTM7752GXT

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
BTM7752G
Manufacturer:
INFINEON/英飞凌
Quantity:
20 000
6.4.4
Device State
1) Previous current sense assignment to be reset by IN1=IN2=low and both high side switches off (see
2) When both high side switches are in on state, the CS provides the sense signal for the high side switch, which has been
3) In short circuit of HSS or LSS, the junction temperature will arise and as soon as the over temperature shut down threshold
Data Sheet
Normal operation
Open-Load detection
mode
Over-voltage (OV)
Under-voltage (UV)
Overtemperature or
short circuit of HSS or
LSS
Current limitation
mode half bridge 1
Current limitation
mode half bridge 2
Inputs:
0 = Logic LOW
1 = Logic HIGH
X = 0 or 1
turned on first.
is reached the device will shut down and latch the status. Short circuit of HSS and LSS itself won’t be detected as failure.
3)
Truth Table
Inputs
INH
0
1
1
1
1
0
0
0
X
X
0
1
X
X
1
1
0
1
1
0
Switches
OFF = switched off
ON = switched on
X = switched on or off
IN1
0
0
0
1
1
0
1
1
X
X
0
X
1
X
0
1
1
X
X
X
IN2
0
0
1
0
1
1
0
1
X
X
0
X
X
1
X
X
X
0
1
1
Outputs
HS1 LS1 HS2 LS2 IS
OFF OFF OFF OFF 0
OFF ON
OFF ON
ON
ON
OFF OFF ON
ON
ON
ON
OFF OFF OFF OFF 0
OFF OFF OFF OFF 0
OFF OFF OFF OFF 1
ON
OFF ON
OFF OFF X
X
X
X
OFF OFF ON
OFF ON
OFF OFF OFF CS HS1
OFF ON
OFF ON
OFF X
X
X
X
19
OFF ON
ON
X
ON
OFF ON
OFF OFF 1
OFF CS HS2
OFF
OFF CS HS2
OFF CS
OFF 1
X
X
X
OFF 1
Status Flag IS:
CS = Current sense mode
1 = Logic HIGH (error)
0
CS HS1
CS
1
1
1
1
Block Description and Characteristics
2)
2)
1)
1)
1)
1)
Mode
Stand-by mode, reset
Enable Open-load detection
Enable Open-load detection
Shut-down of LSS, HSS
activated, error detected
UV lockout, reset
Stand-by mode, reset of latch
Shut-down with latch, error
detected
Short Circuit in LS1 detected,
half bridge 2 operates in normal
mode
Short Circuit in HS1 detected,
half bridge 2 operates in normal
mode
Short Circuit in HS1 detected
Short Circuit in LS2 detected,
half bridge 1 operates in normal
mode
Short Circuit in HS2 detected,
half bridge 1 operates in normal
mode
Short Circuit in HS2 detected
High Current H-Bridge
Rev. 2.0, 2010-05-28
Chapter
BTM7752G
6.4.3).

Related parts for BTM7752G