Specifications of B803

Frequency
0.02 Hz to 2 MHz
Equipment Type
Sweep Function Generator
Lead Free Status / Rohs Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
B8033
Manufacturer:
EPCOS/爱普科斯
Quantity:
20 000
Part Number:
B8034
Manufacturer:
EPCOS/爱普科斯
Quantity:
20 000
24
B801
Protek Test & Measurement
40 Boroline Road, Allendale, NJ 07401 Tel: 201-760-9898 Fax: 201-760-9888
Website: www.protektest.com E-Mail: sales@protektest.com
S P E C I F I C A T I O N S
[ B801/B803 ]
Output Characteristics
Waveforms:
Frequency Range:
Tuning Range:
Frequency Accuracy:
Frequency Stability:
Amplitude:
DC Offset:
Output Impedance:
Variable Symmetry:
Output Attenuation:
(20dB ±1dB step and 0 to 20dB variable)
VCF Input:
with an input voltage level from 0 to -10V
Sine Wave
Distortion:
Amplitude Flatness:
Square Wave
Rise/Fall Time:
Triangle Wave
Linearity:
Sweep Characteristics
Sweep Mode:
Sweep Time:
Sweep Width:
B803
> 98% to 100kHz
Variable from < -10V to > +10V open circuit
100:1 tuning range
< 2% from 10Hz to 100kHz
2V to 20V P-P open circuit
Sine, Square, Triangle, Pulse, Ramp
Variable from 20ms to 2s
Linear
Variable from 10:1 to 1000:1
100:1 on each range
< 100ns at max amplitude
B801/B803
Generator
Seven frequency ranges with 100:1 control on each
range
Built-in 2MHz, 4 digit frequency counter (B803)
Less than 2% sinewave distortion
Variable symmetry
DC offset and Voltage Controlled Frequency input
TTL sync output
.02Hz to 2MHz in 7 ranges
50Ω ±5%
1:1 to 4:1
0 to 40dB
0.1% after 20 minutes
B801:
0.3dB
B810
5% of FS;
B803:
2MHz Sweep Function
B801
± (0.01% +1D)
Sweep Function Generators
2 and 10 MHz
Frequency Counter
Modes:
Measuring Range:
Accuracy:
Max Input V:
General Specifications
Power Requirements:
±10%; Frequency: 48Hz to 66Hz
Power Consumption:
Operating Temperature:
Size:
Supplied Accessories:
[ B810 ]
Output Characteristics
Frequency Range:
Output Level:
Waveforms:
Attenuator:
Impedance:
Sine Wave
Flatness:
Triangle Wave
Linearity:
Square Wave
Rise/Fall Time:
Pulse
Duty Cycles:
3.3" H × 8.8" W × 10.1" D;
Internal and External;
±0.2dB: 0.01Hz to 100kHz;
> 99%
±0.01% ± 1 count;
20dB, 40dB, 60dB & 20dB variable
50Ω;
Sine, Square, Ramp, Pulse
140V P-P;
20:80 to 80:20 may be obtained
±10 Volts into 50Ω
CE
DC Offset:
25ns (into 50Ω)
10Hz to 2MHz.
0.01Hz to 10MHz in 9 ranges
(B803)
Approx. 5VA
AC Line Voltage: 100/120/220/240V
Input Impedance:
Manual, Line cord, BNC cable
0 to 50°C
B803
Display:
Sensitivity:
±5V in to 50Ω
Weight:
Distortion:
4 digit red LEDS
8 lbs.
50mV RMS
1MΩ
B810
Sweep Function Generator
Wide (0.01HZ to 10MHz) Frequency Range
Burst and Triggered mode
Sweep start/stop capability
Six digit LED frequency readout
Log. or Lin. sweep
Built-in 10MHz frequency counter
External FM with the VCG input
Output can be amplitude modulated
0.5%
10MHz
Operating Modes : CW, Triggered, gated, burst, sweep
Trigger/Gate Input Level:
Trigger/Gate Freq. Range:
Sweep
Types:
Sweep Time:
Start Freq:
AM Modulation
Type:
Modulation Level:
Modulation Frequency:
FM Modulation
Type:
Tuning Range:
Frequency Counter
Measuring Range:
Gate Time:
Accuracy:
Max Input V:
General Specifications
Power Requirements:
±10%; Frequency: 48Hz to 66Hz
Power Consumption:
Operating Temperature:
Size:
Supplied Accessories:
CE
3.8" H × 11.5" W × 12.5" D;
Internal
External
Linear and Log
±0.01%;
0.01Hz to 10MHz
0.01s, 0.1s, 1s, 10s
250V DC and AC RMS;
1ms to 10s;
1000:1 with an input voltage of 0 to –5V (VCG)
0 to 100%;
1Hz to 10MHz
Sensitivity:
B810
9VA
AC Line Voltage: 100/120/220/240V
Manual, Line cord, BNC cable
DC to 1MHz
0 to 50°C
Sweep Width:
TTL;
0.1Hz to1MHz
Modulation Voltage:
Burst Time:
50mV RMS
Weight:
Input Impedance:
Variable to 100:1
8 lbs.
1ms to 10s
0 to 5V
1MΩ