ICB2FL03G Infineon Technologies, ICB2FL03G Datasheet - Page 40

no-image

ICB2FL03G

Manufacturer Part Number
ICB2FL03G
Description
LED Drivers
Manufacturer
Infineon Technologies
Datasheet

Specifications of ICB2FL03G

Packages
PG-DSO-16
Lead Free Status / Rohs Status
 Details
Other names
ICB2FL03GXT

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ICB2FL03G
Manufacturer:
INFINEON
Quantity:
7 500
Part Number:
ICB2FL03G
0
Company:
Part Number:
ICB2FL03G
Quantity:
4 800
4
Table 3
Supply voltage V
before power-up
Supply voltage V
after power-up
Current into LVS pin < 12µA
(typ.) before power-up
Voltage at RES pin > 1.6 V
before power-up
Voltage at RES pin > 3.2 V
Bus voltage < 12.5% of rated
level 10 µs after power-up
Bus voltage < 12.5 %
of rated level
Bus voltage < 12.5%
of rated level
Bus voltage < 75%
of rated level
add. shut down delay 120µs
Bus voltage < 95% of rated
level during start-up
Bus voltage > 105% of rated
level 10µs after power-up
Bus voltage > 109% of rated
level in active operation
Bus voltage > 109% of rated
level in active operation
+/- peak level of lamp voltage
at pin LVS above threshold
DC level of lamp voltage
above +/- threshold
Capacitive load 1
Capacitive load 2,
operation below resonance
Preliminary Data Sheet
Description of Fault
Protection Functions Matrix
Protection Functions Matrix
cc
cc
< 14.0 V
< 10.6 V
Below start-
up threshold
Below UVLO
threshold
Open
filament HS
Open
filament LS
Open
filament LS
Open loop
detection
Open loop
detection
Shut-down
option
Under-
voltage
Timeout max
start-up time
Over-
voltage
PFC
overvoltage
Inverter
overvoltage
EOL 1
overvoltage
EOL 2
rect. effect
Cap load 1
idling
Cap. load 2
overload
Characteristics of Fault
N
U
U
N
U
S
S
S
S
F
S
A
S
F
F
F
F
2500ms
2500ms
625ms
625ms
100µs
100µs
620µs
620µs
620µs
80ms
84µs
1µs
5µs
1µs
1µs
5µs
5µs
40
Operating Mode Detection Active
X
X
X
X
Controller for Fluorescent Lamp Ballasts
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
Protection Functions Matrix
X
X
X
X
X
X
X
X
X
X
X
Prevents power-up
Power-down, reset
failure latch
Prevents power-up
Prevents power-up
Power down, latched
fault mode, 1 restart
Keep Gate drives off, re-
start after V
Stops PFC FET until
V
Power down, restart
when V
Power down, 100ms
delay, restart, skip pre-
heating max 7 times
Power down, 200ms
delay, restart
Keep Gate drives off, re-
start after Vcc hysteresis
Stops PFC FET until
V
Power down, restart
when V
Power down, latched
fault mode, 1 restart
Power down, latched
fault mode, 1 restart
Power down, latched
fault mode, 1 restart
Power down, latched
fault mode, 1 restart
BUS
BUS
Consequence
< 105%
> 12.5%
V1.1, 2012-04-10
BUS
BUS
ICB2FL03G
> 12.5%
<105%
cc
hysteresis

Related parts for ICB2FL03G