Datasheets

Specifications of HBLXT9860AHC.B4

Rohs Status
RoHS non-compliant
Tx/rx Type
Ethernet
Voltage - Supply
3.15 V ~ 3.45 V
Current - Supply
42mA
Mounting Type
Surface Mount
Package / Case
208-QFP Exposed Pad, 208-eQFP, 208-HQFP
Delay Time
-
Capacitance - Input
-
Other names
837730

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HBLXT9860AHC.B4
Manufacturer:
Intel
Quantity:
10 000
LXT9860/9880
Advanced 10/100 Repeater with Integrated Management
The LXT9880 is the next-generation repeater family, integrated with eight 10/100 transceivers.
The LXT9880 is compatible with previous generations of Intel repeaters from the LXT980 and
LXT918 families. Eight ports directly support 100BASE-TX/10BASE-T copper media. Two
additional Media Independent Interface (MII) ports (10/100 Mbps selectable) connect to Media
Access Controllers (MACs) for bridge/switch applications. The LXT9860 offers the same
features and functionality in a six-port device. This data sheet uses the singular designation
“LXT98x0” to refer to both devices.
The LXT98x0 provides auto-negotiation with parallel detection for the PHY ports. The
LXT98x0 provides two internal repeater state machines—one operating at 10 Mbps and one at
100 Mbps. Once configured, the LXT98x0 automatically connects each port to the appropriate
repeater. The LXT98x0 also provides two Inter-Repeater Backplanes (IRBs) for expansion —
one operating at 10 Mbps and one at 100 Mbps. Up to 240 twisted-pair and MII ports can
logically be combined into one repeater. The LXT98x0 supports SNMP and RMON
management via on-chip 32- and 64-bit counters. The counters and control functions are
accessible via a high-speed Serial Management Interface (SMI).
Product Features
For More Information…
Refer to
As of January 15, 2001, this document replaces the Level One document
known as Advanced 10/100 Repeater with Integrated Management.
Six or eight 10/100 ports with integrated
twisted-pair PHYs including integrated
filters.
Two 10/100 MIIs for bridging.
Independent segments for 10 Mbps and
100 Mbps operation.
Cascadable Inter-Repeater Backplanes
(IRBs), with option for 5V stacking
compatibility.
Hardware assist for RMON and the
Repeater MIB.
“Section 1.0, “Other Related Documents…” on page
High-speed Serial Management Interface
(SMI).
Two address-tracking registers per port.
Source Address matching function.
Integrated LED drivers with user-selectable
modes.
Available in 208-pin QFP package.
Operating temperature range: 0-70 C,
ambient.
Available in extended temperature range:
-40 to +85 C, ambient.
11” .
Order Number: 248987-003
Datasheet
August 2001

Related parts for HBLXT9860AHC.B4

HBLXT9860AHC.B4 Summary of contents

Page 1

... Advanced 10/100 Repeater with Integrated Management The LXT9880 is the next-generation repeater family, integrated with eight 10/100 transceivers. The LXT9880 is compatible with previous generations of Intel repeaters from the LXT980 and LXT918 families. Eight ports directly support 100BASE-TX/10BASE-T copper media. Two additional Media Independent Interface (MII) ports (10/100 Mbps selectable) connect to Media Access Controllers (MACs) for bridge/switch applications ...

Page 2

... Information in this document is provided in connection with Intel property rights is granted by this document. Except as provided in Intel’s Terms and Conditions of Sale for such products, Intel assumes no liability whatsoever, and Intel disclaims any express or implied warranty, relating to sale and/or use of Intel products including liability or warranties relating to fitness for a particular purpose, merchantability, or infringement of any patent, copyright or other intellectual property right ...

Page 3

Advanced 10/100 Repeater with Integrated Management — LXT9860/9880 Contents 1.0 Other Related Documents….......................................................................................... 11 2.0 Pin Assignments and Signal Descriptions .................................................................. 12 3.0 Functional Description .................................................................................................. 31 3.1 Introduction.......................................................................................................... 31 3.2 Port Configuration ............................................................................................... 32 3.2.1 Auto-Negotiation..................................................................................... 32 3.2.2 Forced ...

Page 4

LXT9860/9880 — Advanced 10/100 Repeater with Integrated Management 3.8 IRB Operation ..................................................................................................... 47 3.8.1 IRB Signal Types ................................................................................... 48 3.8.2 IRB Isolation ........................................................................................... 48 3.8.3 10 Mbps-Only Operation ........................................................................ 48 3.8.3.1 MAC IRB Access....................................................................... 48 3.8.3.2 Management Master Chain Arbitration...................................... ...

Page 5

Advanced 10/100 Repeater with Integrated Management — LXT9860/9880 5.0 Test Specifications......................................................................................................... 75 6.0 Register Definitions ....................................................................................................... 87 6.1 Register Map ....................................................................................................... 87 6.2 Counter Registers ............................................................................................... 95 6.2.1 Port Counter Registers........................................................................... 95 6.2.2 RMON Counter Registers ...................................................................... 96 6.3 Ethernet ...

Page 6

LXT9860/9880 — Advanced 10/100 Repeater with Integrated Management Figures 1 LXT98x0 Block Diagram ..................................................................................... 11 2 LXT98x0 Pin Assignments .................................................................................. 12 3 Typical LXT988x Managed Repeater Architectures ........................................... 32 4 MII Interface ........................................................................................................ 34 5 LED Blink Rates .................................................................................................. 39 ...

Page 7

Advanced 10/100 Repeater with Integrated Management — LXT9860/9880 Tables 1 Signal Types........................................................................................................ 13 2 LXT98x0 Pins, Numeric Order ............................................................................ 13 3 MII #1 Signal Descriptions................................................................................... 20 4 MII #2 Signal Descriptions................................................................................... 21 5 Inter-Repeater Backplane Signal Descriptions.................................................... 22 6 Twisted-Pair ...

Page 8

LXT9860/9880 — Advanced 10/100 Repeater with Integrated Management 50 Port Address Tracking Registers ........................................................................ 99 51 Search Address/Search Address Match Register ............................................. 100 52 Search Address Register Bit Assignments ....................................................... 100 53 Search Match Address Bit Assignments ........................................................... 100 54 ...

Page 9

Advanced 10/100 Repeater with Integrated Management — LXT9860/9880 Revision History Date Revision August 2001 003 January 2001 002 Datasheet Document #: 248987 Revision#: 003 Rev Date: 08/07/01 Page Description 75 Changed Absolute Maximum Ratings Supply Voltage value to 4.0V. Title ...

Page 10

...

Page 11

... LXT98x and more recent LXT98x0 devices. The LXT9883/LXT9863 Data Sheet specifically details the unmanaged eight-port and six-port devices. The High-Speed Serial Management Interface (formerly Application Note 64) explains how to connect an SCC to Intel devices and how to implement management across a network system. Datasheet Document #: 248987 Revision#: 003 ...

Page 12

LXT9860/9880 — Advanced 10/100 Repeater with Integrated Management 2.0 Pin Assignments and Signal Descriptions Figure 2. LXT98x0 Pin Assignments RESET ....... 53 CLK25 ....... 54 IR10ISO ....... 55 IR100ISO ....... 56 RECONFIG ....... 57 SRX ....... 58 STX ....... 59 ...

Page 13

Advanced 10/100 Repeater with Integrated Management — LXT9860/9880 Table 1. Signal Types Type Name I Input O Output I/O Bidirectional A Analog OD Open Drain OS Open Source PD Pull Down PU Pull Clamp Table 2. LXT98x0 ...

Page 14

LXT9860/9880 — Advanced 10/100 Repeater with Integrated Management Table 2. LXT98x0 Pins, Numeric Order Pin Symbol 22. MII1_TXEN 23. MII1_TXCLK 24. MII1_TXER 25. CONFIG1/CF 26. MII1RXER 27. GND 28. VCC 29. MII1_RXCLK 30. MII1_RXDV 31. MII1_RXD0 32. MII1_RXD1 33. CONFIG/CFG_DT ...

Page 15

Advanced 10/100 Repeater with Integrated Management — LXT9860/9880 Table 2. LXT98x0 Pins, Numeric Order Pin Symbol 56. IR100ISO 57. RECONFIG 58. SRX 59. STX 60. SERCLK 61. VCC 62. GND 63. SER_MATCH 64. MMSTROUT 65. ARBOUT 66. NC 67. MGR_PRES ...

Page 16

LXT9860/9880 — Advanced 10/100 Repeater with Integrated Management Table 2. LXT98x0 Pins, Numeric Order Pin Symbol 86. GND 87. PORT1_LED3 88. PORT1_LED2 89. PORT1_LED1 90. GND 91. PORT2_LED3 92. PORT2_LED2 93. PORT2_LED1 94. GND 95. PORT3_LED3 96. PORT3_LED2 97. PORT3_LED1 ...

Page 17

Advanced 10/100 Repeater with Integrated Management — LXT9860/9880 Table 2. LXT98x0 Pins, Numeric Order Pin Symbol 120. VCCR 121. TPOP3 122. TPON3 123. GND 124. TPON4 125. TPOP4 126. VCCT 127. VCCR 128. TPIN4 129. TPIP4 130. GND 131. GND ...

Page 18

LXT9860/9880 — Advanced 10/100 Repeater with Integrated Management Table 2. LXT98x0 Pins, Numeric Order Pin Symbol 154. TPOP8 155. VCCR 156. TPIN8 157. TPIP8 158. GND 159. TxSLEW_0 160. TxSLEW_1 161. PORT5_LED3 162. PORT5_LED2 163. PORT5_LED1 164. GND 165. PORT6_LED3 ...

Page 19

Advanced 10/100 Repeater with Integrated Management — LXT9860/9880 Table 2. LXT98x0 Pins, Numeric Order Pin Symbol 185. LEDSEL1 COL10_LED 186. ARBSELECT COL100_LED 187. MII2_CRS 188. MII2_COL 189. GND 190. VCC 191. MII2_TXD3 192. MII2_TXD2 193. MII2_TXD1 194. MII2_TXD0 195. MII2_TXEN ...

Page 20

LXT9860/9880 — Advanced 10/100 Repeater with Integrated Management Table 3. MII #1 Signal Descriptions Pin Symbol MII1_SPD 9 31 MII1_RXD0 32 MII1_RXD1 34 MII1_RXD2 35 MII1_RXD3 30 MII1_RXDV 29 MII1_RXCLK 26 MII1_RXER MII1_TXER 24 23 MII1_TXCLK 22 MII1_TXEN 21 MII1_TXD0 ...

Page 21

Advanced 10/100 Repeater with Integrated Management — LXT9860/9880 Table 4. MII #2 Signal Descriptions Pin Symbol 18 MII2_SPD 205 MII2_RXD0 206 MII2_RXD1 207 MII2_RXD2 208 MII2_RXD3 204 MII2_RXDV 203 MII2_RXCLK 202 MII2_RXER MII2_TXER 197 196 MII2_TXCLK MII2_TXEN 195 194 MII2_TXD0 ...

Page 22

LXT9860/9880 — Advanced 10/100 Repeater with Integrated Management Table 5. Inter-Repeater Backplane Signal Descriptions Pin Symbol 39 COMP_SEL 3 36 IR100CFS 37 IR100CFSBP 38 IR100SNGL 40 IR100COL 41 IR100DEN 42 IR100DV Input Output, I/O = ...

Page 23

Advanced 10/100 Repeater with Integrated Management — LXT9860/9880 Table 5. Inter-Repeater Backplane Signal Descriptions (Continued) Pin Symbol 43 IR100DAT0 44 IR100DAT1 45 IR100DAT2 48 IR100DAT3 49 IR100DAT4 50 IR100CLK 56 IR100ISO 11 IR10DAT 12 IR10CLK 6 IR10DEN 10 IR10ENA 3 ...

Page 24

LXT9860/9880 — Advanced 10/100 Repeater with Integrated Management Table 5. Inter-Repeater Backplane Signal Descriptions (Continued) Pin Symbol 4 IR10COLBP 4 2 IR10CFS 5 IR10CFSBP 80 MACACTIVE 55 IR10ISO 81 HOLDCOL MMSTRIN 201 64 MMSTROUT Input ...

Page 25

Advanced 10/100 Repeater with Integrated Management — LXT9860/9880 Table 6. Twisted-Pair Port Signal Descriptions Pin Symbol 107, 108 TPOP1, TPON1 111, 110 TPOP2, TPON2 121, 122 TPOP3, TPON3 125, 124 TPOP4, TPON4 136, 137 TPOP5, TPON5 140, 139 TPOP6, TPON6 ...

Page 26

LXT9860/9880 — Advanced 10/100 Repeater with Integrated Management Table 7. Serial Management Interface Signal Descriptions Pin Symbol 57 RECONFIG 63 SER_MATCH 58 SRX 59 STX 60 SERCLK 198 ARBIN 65 ARBOUT 186 ARBSELECT 67 MGR_PRES Input, O ...

Page 27

Advanced 10/100 Repeater with Integrated Management — LXT9860/9880 Table 8. LED Signal Descriptions Pin Symbol 184 LEDSEL0 185 LEDSEL1 175 LEDABGSEL 183 AUTOBLINK 83 LEDDAT 84 LEDLAT LEDCLK 82 CFG_CLK 176 PORT8_LED1 171 PORT7_LED1 167 PORT6_LED1 163 PORT5_LED1 101 PORT4_LED1 ...

Page 28

LXT9860/9880 — Advanced 10/100 Repeater with Integrated Management Table 8. LED Signal Descriptions (Continued) Pin Symbol 185 COL10_LED 186 COL100_LED 183 ACT10_LED 184 ACT100_LED Input Output, I/O = Input/Output Digital Analog, ...

Page 29

Advanced 10/100 Repeater with Integrated Management — LXT9860/9880 Table 9. Power Supply and Indication Signal Descriptions (Continued) Pin Symbol 1, 7, 15, 27, 46, 62, 75, 86, 90, 94, 98, 103, 109, 116, 117, 123, 130, GND 131, 138, 144, ...

Page 30

LXT9860/9880 — Advanced 10/100 Repeater with Integrated Management Table 11. Miscellaneous Signal Descriptions Pin Symbol 53 RESET 54 CLK25 72 CHIPID0 73 CHIPID1 CONFIG( CFG_DT CONFIG( CFG_LD Input Output, I/O = ...

Page 31

Advanced 10/100 Repeater with Integrated Management — LXT9860/9880 Table 11. Miscellaneous Signal Descriptions (Continued) Pin Symbol CFG_CLK/ 82 LEDCLK 182 IRQ 51, 52, NC 66,178 Input Output, I/O = Input/Output Digital ...

Page 32

LXT9860/9880 — Advanced 10/100 Repeater with Integrated Management Figure 3. Typical LXT988x Managed Repeater Architectures Buffer 10M Backplane Buffer 100M Backplane Management to MII to MII Bridge 3.2 Port Configuration The LXT98x0 powers up in auto-negotiation mode for all twisted-pair ...

Page 33

Advanced 10/100 Repeater with Integrated Management — LXT9860/9880 3.2.2 Forced Operation A port can be directly configured to operate in either 100BASE-TX or 10BASE-T. When a port is configured for forced operation, it immediately operates in the selected mode. All ...

Page 34

... Each 10BASE-T port can detect and automatically correct for polarity reversal on the TPIP/N inputs. The 10BASE-T interface provides integrated filters using Intel’s patented filter technology. These filters facilitate low-cost stack designs to meet EMI requirements. ...

Page 35

Advanced 10/100 Repeater with Integrated Management — LXT9860/9880 Address assignment is provided via one of two arbitration mechanisms which are activated whenever the device is powered up or reset/reconfigured. Refer to page 52. 3.3.4 Serial PROM Interface The serial PROM ...

Page 36

LXT9860/9880 — Advanced 10/100 Repeater with Integrated Management — The normal algorithm, which complies with the IEEE specification 802.3u, is available through the management interface. This algorithm un-partitions a port only when data is transmitted to the port for 450-560 ...

Page 37

Advanced 10/100 Repeater with Integrated Management — LXT9860/9880 3.5 Management Support 3.5.1 Configuration and Status The LXT98x0 provides management control and visibility of the following functions: • Counter Reset and Zeroing • Auto-negotiation (Control, Status, Advertisement, Link Partner, and Expansion) ...

Page 38

LXT9860/9880 — Advanced 10/100 Repeater with Integrated Management 3.6.2 Clock A stable, external 25 MHz reference clock source (TTL) is required to the CLK25 pin. The reference clock is used to generate transmit signals and recover receive signals. A crystal-based ...

Page 39

Advanced 10/100 Repeater with Integrated Management — LXT9860/9880 100 Mbps IRB IR100CFS IR100CFSBP IR100DV IR100CLK 3.7 LED Operation The LXT98x0 drives the most commonly used LEDs directly (see page 42). The less frequently used LEDs are optionally driven via a ...

Page 40

LXT9860/9880 — Advanced 10/100 Repeater with Integrated Management 3.7.4 Serial LED Interface The LXT98x0 provides a serial interface to drive additional LEDs via external 8-bit Serial-to- Parallel converters. A maximum of 30 LEDs can be driven, using four S/P devices. ...

Page 41

Advanced 10/100 Repeater with Integrated Management — LXT9860/9880 Figure 7. Serial LED Port Signaling LEDDAT LEDLAT LEDCLK LEDDAT MII PORTS-LED1,2,3 LEDLAT LEDDAT b0 b1 100 MHz LEDCLK Qa’-Qh’ (‘595) b7-b0 b0, b7-b1 b1, b0, b7-b2 Qa-Qh (‘164) ...

Page 42

LXT9860/9880 — Advanced 10/100 Repeater with Integrated Management Table 13. ACTGLED Display Modes LEDABGSEL = 0 LED (Base-10) ACTG 8 60+% Activity ACTG 7 50% Activity ACTG 6 40% Activity ACTG 5 30% Activity ACTG 4 20% Activity ACTG 3 ...

Page 43

Advanced 10/100 Repeater with Integrated Management — LXT9860/9880 Table 14. LED Terms Term Port_Enabled True if port is enabled. (see Link_Enabled True if link detection is enabled (see True if link is enabled and link is detected or if link ...

Page 44

LXT9860/9880 — Advanced 10/100 Repeater with Integrated Management 3.7.6.1 LED Mode 1 Mode 1 operations are described in Table 15. LED Mode 1 Indications LED Operating Mode 10 Mbps operation PORTnLED1 100 Mbps operation 10 Mbps operation PORTnLED2 100 Mbps ...

Page 45

Advanced 10/100 Repeater with Integrated Management — LXT9860/9880 3.7.6.2 LED Mode 2 Mode 2 operations are described in Table 16. LED Mode 2 Indications LED PORTnLED1 Any PORTnLED2 Auto- negotiate enabled PORTnLED3 Auto-negotiate disabled Collision and Any Activity LEDs Manager ...

Page 46

LXT9860/9880 — Advanced 10/100 Repeater with Integrated Management 3.7.6.3 LED Mode 3 Mode 3 operations are described in Table 17. LED Mode 3 Indications LED Operating Mode 10 Mbps operation PORTnLED1 100 Mbps operation 10 Mbps or 100 Mbps PORTnLED2 ...

Page 47

Advanced 10/100 Repeater with Integrated Management — LXT9860/9880 3.7.6.4 LED Mode 4 Mode 4 operations are described in Table 18. LED Mode 4 Indications LED Operating Mode 10 Mbps operation PORTnLED1 100 Mbps operation 10 Mbps operation PORTnLED2 100 Mbps ...

Page 48

LXT9860/9880 — Advanced 10/100 Repeater with Integrated Management 3.8.1 IRB Signal Types IRB signals can be characterized by the following connection types (For Stacking and Cascading connections, see Table 19 on page • Local—connected between devices on the same board ...

Page 49

Advanced 10/100 Repeater with Integrated Management — LXT9860/9880 Figure 8. 100 Mbps IRB Connection IR100CLK IR100DV IR100DAT(4:0) IR100COL IR100SNGL LXT98x0 IR100CFS HUB #1 Cascade Datasheet Document #: 248987 Revision#: 003 Rev Date: 08/07/01 IR100DEN IR100DEN LXT98x0 LXT98x0 (00) (00) IR100CFSBP ...

Page 50

LXT9860/9880 — Advanced 10/100 Repeater with Integrated Management Figure 9. IRB Block Diagram Hub Board 1 Hub Board 2 Hub Board n This diagram shows a single IRB. The LXT98xx actually has two independent IRBs, one per speed/segment. Digital IRB ...

Page 51

Advanced 10/100 Repeater with Integrated Management — LXT9860/9880 Table 20. IRB Signal Details Name IR100DAT<4:0> IR100CLK IR100DV IR100CFS IR100CFSBP IR100COL IR100SNGL IR100DEN IR100ISO IR10DAT IR10CLK IR10ENA IR10CFS IR10CFSBP IR10COL IR10COLBP IR10DEN IR10ISO 1. Isolate and Driver Enable signals are provided ...

Page 52

LXT9860/9880 — Advanced 10/100 Repeater with Integrated Management Figure 10. LXT9880 MII Operation The two LXT98x0 MII ports act as the PHY side of the MII. An external MAC sends TX Data to the LXT98x0 to be repeated to the ...

Page 53

Advanced 10/100 Repeater with Integrated Management — LXT9860/9880 3.10.1.1 Serial Clock SERCLK is a bidirectional pin; direction control is provided by the RECONFIG input. If RECONFIG is High, the LXT98x0 drives SERCLK at 625 kHz. If RECONFIG is Low, SERCLK ...

Page 54

LXT9860/9880 — Advanced 10/100 Repeater with Integrated Management Figure 12. SMI Collision Handling Clk Data Data Data 1. Simultaneous Transmissions, Pkt 1 completes Transmit om falling CLK edge, sample on rising CLK edge. Figure 13. SMI Address Match Indication HUB ...

Page 55

Advanced 10/100 Repeater with Integrated Management — LXT9860/9880 Table 21. SMI Message Fields Message “01111110”. Protocol requires zero insertion after any five consecutive “1”s in the data Start or Stop Flag stream. Identifies board or sub-system. Assigned by one of ...

Page 56

LXT9860/9880 — Advanced 10/100 Repeater with Integrated Management Table 23. SMI Command Set Command Name Value 18 (Hex) Write 04 (Hex) Read 08 (Hex) Request ID 00 (Hex) ConfigChg 10 (Hex) Re-arbitrate Assign 14 (Hex) HubID Set Arbout 0C (Hex) ...

Page 57

Advanced 10/100 Repeater with Integrated Management — LXT9860/9880 Table 24. Typical Serial Management Packets Message 1, 2 Write Read Request 3 Read Response Assign Hub ID (Arb Method 1) Assign Hub ID (Arb Method 2) Set Arbout ...

Page 58

LXT9860/9880 — Advanced 10/100 Repeater with Integrated Management Figure 15. Address Arbitration Mechanisms Network EPROM Mechanism Manager for Address Arbitration SRX/STX PROMDTI/O PROMDTI/O LXT98x0 LXT98x0 SRX/STX SRX/STX SRX/STX SRX/STX LXT980 LXT980 PROMDTI/O PROMDTI/O Serial I/F to Next Module 3.10.3.1 Chain ...

Page 59

Advanced 10/100 Repeater with Integrated Management — LXT9860/9880 on the board listen in and record the ID. The device with ChipID = 00 then transmits Arbitration Request messages on the SMI every 2-3 ms. The request messages from two boards ...

Page 60

LXT9860/9880 — Advanced 10/100 Repeater with Integrated Management Figure 16. Optional R/W Serial PROM Interface CLK DTOUT CS The LXT98x0 drives outgoing data on the falling clock edge. The LXT98x0 samples incoming data on the rising clock edge . 3.12 ...

Page 61

Advanced 10/100 Repeater with Integrated Management — LXT9860/9880 Figure 17. Serial Configuration Interface Parallel Config. Data SER ‘165 Figure 18. Serial Configuration Interface Signaling CFG_ LD CFG_CLK 100 MHz ...

Page 62

LXT9860/9880 — Advanced 10/100 Repeater with Integrated Management • Do not route any digital signals between the LXT98x0 and the RJ-45 connectors at the edge of the board. • Do not extend any circuit power and ground plane past the ...

Page 63

... DC-to-DC converters. Many of these issues can be improved by following good general design guidelines. In addition, Intel recommends filtering between the power supply and the analog VCC pins of the LXT98x0. Filtering has two benefits. First, it keeps digital switching noise out of the analog circuitry inside the LXT98x0, which helps line performance ...

Page 64

LXT9860/9880 — Advanced 10/100 Repeater with Integrated Management • Place the layers so the TPOP/N and TPIP/N signals are routed near or next to the ground plane. For EMI more important to shield TPOP/N than TPIP/N. 4.3.1.4 Chassis ...

Page 65

Advanced 10/100 Repeater with Integrated Management — LXT9860/9880 Figure 21. Power and Ground Connections LXT9880 VCCT GND VCC GND RBIAS GND VCCR GND VCC GND 4.3.2 MII Terminations The LXT98x0 MIIs have high output impedance (250-350 ). To minimize reflections, ...

Page 66

LXT9860/9880 — Advanced 10/100 Repeater with Integrated Management • Place magnetics as close as possible to the LXT98x0. • Keep transmit pair traces short. • Do not route transmit pair adjacent to a ground plane. Eliminate planes under the transmit ...

Page 67

Advanced 10/100 Repeater with Integrated Management — LXT9860/9880 Table 26. Oscillator Manufacturers Manufacturer CTS Epson America Figure 22. Typical Twisted-Pair Port Interface and Power Supply Filtering 270 pF 5% LXT98x3 TPFIP TPIP TPIN 270 pF 5% TPOP .01 F TPON ...

Page 68

LXT9860/9880 — Advanced 10/100 Repeater with Integrated Management 4.3.5 SMI and PROM Circuits Figure 23. Typical Serial Management Interface Connections SRX STX Figure 24. Serial Controller Connection Showing PAL RTxCA 8530 68 74xx05 VCC 1. When not transmitting STX goes ...

Page 69

Advanced 10/100 Repeater with Integrated Management — LXT9860/9880 Figure 25. Serial PROM Interface 93CS46 Figure 26. Typical Reset Circuit 1. t(CR1 > Power Supply Ramp Up Time. R2 discharges C when supply goes away. The ‘14 is needed for multiple ...

Page 70

LXT9860/9880 — Advanced 10/100 Repeater with Integrated Management the current, the configuration value is a ‘0’. The LXT98x0 detects the configuration value following reset and then selects the appropriate output drive circuit (open drain or source). If the LED function ...

Page 71

Advanced 10/100 Repeater with Integrated Management — LXT9860/9880 • Miscellaneous LEDs (Repeat of Collision10/100, Manager Present, Repeat of Activity10/100, Global Fault, RPS Fault) • ACTGLED10 • ACTGLED100 This allows the user to leave off devices in the serial-to-parallel chain if ...

Page 72

LXT9860/9880 — Advanced 10/100 Repeater with Integrated Management 4.4.1 Local Backplane—3.3V Only The LXT98x0 local backplane operates at 3.3V only. LXT98x and LXT91x devices operate at 5V. LXT98x0 devices are, therefore, not cascadable with LXT98x and LXT91x devices. Note: Do ...

Page 73

Advanced 10/100 Repeater with Integrated Management — LXT9860/9880 The configuration input must be connected to 5V for compatibility with LXT98x or LXT91x-based designs. The 5V can be supplied from the stacking cable source must exist within the ...

Page 74

LXT9860/9880 — Advanced 10/100 Repeater with Integrated Management Figure 30. Typical 100 Mbps IRB Implementation Stack or Segment Connector ’245 IR100CLKBP IR100CLK A B IR100DATBP IR100DAT IR100DVBP\ IR100DV\ IR100DEN\ DIR 91 ISOLATE ENA 1%* 1 IR100CFSBP\ COMP_SEL 1. In stacked ...

Page 75

Advanced 10/100 Repeater with Integrated Management — LXT9860/9880 5.0 Test Specifications Note: Table 27 through Table 44 the LXT98x0 and are subject to change. Final values will be guaranteed by test except, where noted, by design. The minimum and maximum ...

Page 76

LXT9860/9880 — Advanced 10/100 Repeater with Integrated Management Table 30. I/O Electrical Characteristics Parameter Input Low voltage Input High voltage Hysteresis voltage Output Low voltage Output Low voltage (LED) Output High voltage Input Low current Input High current Output rise ...

Page 77

Advanced 10/100 Repeater with Integrated Management — LXT9860/9880 Table 31. 100 Mbps IRB Electrical Characteristics (Continued) Parameter IR100CFS current IR100CFSBP current IR100CFS/BP voltage 1. Typical values are at 25° C and are for design aid only; they are not guaranteed ...

Page 78

LXT9860/9880 — Advanced 10/100 Repeater with Integrated Management Table 33. 100BASE-TX Transceiver Electrical Characteristics Parameter Peak differential output voltage (single ended) Signal amplitude symmetry Signal rise/fall time Rise/fall time symmetry Duty cycle distortion Overshoot 1. Typical values are at 25 ...

Page 79

Advanced 10/100 Repeater with Integrated Management — LXT9860/9880 Figure 32. 100 Mbps TP Port-to-Port Delay Timing Normal Propagation TP Input Output Collision Jamming P Input #1 TP Input # Output Jam Table 35. 100 ...

Page 80

LXT9860/9880 — Advanced 10/100 Repeater with Integrated Management Figure 33. 100BASE-TX MII-to-TP Port Timing TX_CLK t 2A TXD, TX_EN, TX_ER t 2C CRS TPOP/N Table 36. 100BASE-TX MII-to-TP Port Timing Parameters Parameter TXD, TX_EN, TX_ER Setup to TX_CLK High TXD, ...

Page 81

Advanced 10/100 Repeater with Integrated Management — LXT9860/9880 Figure 34. 100BASE-TX TP-to-MII Timing TPIP CRS RXD, RX_DV, RX_ER RX_CLK t COL 3F Table 37. 100BASE-TX TP-to-MII Timing Parameters Parameter TPIP CRS asserted TPIP/N quiet to CRS ...

Page 82

LXT9860/9880 — Advanced 10/100 Repeater with Integrated Management Figure 35. 10BASE-T MII-to-TP Timing TX_CLK t 10A TXD, TX_EN, TX_ER t 10C CRS Table 38. 10BASE-T MII-to-TP Timing Parameters Parameter TXD, TX_EN, TX_ER Setup to TX_CLK High TXD, TX_EN, TX_ER Hold ...

Page 83

Advanced 10/100 Repeater with Integrated Management — LXT9860/9880 Figure 36. 10BASE-T TP-to-MII Timing TPIP/N t 11A CRS RXD, RX_DV, RX_ER RX_CLK t 11D COL Table 39. 10BASE-T TP-to-MII Timing Parameters Parameter TPIP CRS asserted CRS asserted to RXD, ...

Page 84

LXT9860/9880 — Advanced 10/100 Repeater with Integrated Management Figure 37. 100 Mbps TP-to-IRB Timing TPIP/N t 12A IR100DV IR100CFS 1R100COL IR100DAT<4:0> IR100CLK Table 40. 100 Mbps TP-to-IRB Timing Parameters Parameter TPIP/N to IR100DV Low IR100DAT to IR100CLK setup time. IR100DAT ...

Page 85

Advanced 10/100 Repeater with Integrated Management — LXT9860/9880 Table 41. 10 Mbps TP-to-IRB Timing Parameters Parameter TPIP/N to IR10ENA Low IR10CLK rising edge to IR10DAT rising edge. IR10CLK rising edge to IR10DAT falling edge. 1. This table contains propagation delays ...

Page 86

LXT9860/9880 — Advanced 10/100 Repeater with Integrated Management Table 42. 10 Mbps IRB-to-TP Port Timing Parameters Parameter MACACTIVE to IR10ENA 3 assertion delay IR10DAT (input) to IR10CLK setup time IR10CLK to IR10DAT (input) hold time IR10ENA asserted to TPOP/N active ...

Page 87

Advanced 10/100 Repeater with Integrated Management — LXT9860/9880 Figure 41. PROM Interface Timing PROM_CLK t 16A PROM_CS PROM_DTOUT PROM_DTIN Table 44. PROM Interface Timing Characteristics Parameter PROM_CLK CLK to PROM_CS delay CLK to PROM_DTOUT delay PROM_DTIN to CLK setup time ...

Page 88

LXT9860/9880 — Advanced 10/100 Repeater with Integrated Management Table 45. Register Map Class rptrMonitorPortReadableFrames rptrMonitorPortReadableOctets(Lower/Upper) rptrMonitorPortFrameCheckSequence rptrMonitorPortAlignmentErrors rptrMonitorPortFramesTooLong Port Counters: TP and MII ports rptrMonitorPortShortEvents rptrMonitorPortRunts formula: rptrMonitorPortCollisions ((N-1)*16) + offset rptrMonitorPortLateEvents N = port number. rptrMonitorPortVeryLongEvents 0 < N ...

Page 89

Advanced 10/100 Repeater with Integrated Management — LXT9860/9880 Table 45. Register Map (Continued) Class rptrMonitorPortIsolates - port 1 rptrMonitorPortIsolates - port 2 rptrMonitorPortIsolates - port 3 rptrMonitorPortIsolates - port 4 rptrMonitorPortIsolates - port 5 rptrMonitorPortIsolates - port 6 rptrMonitorPortIsolates - ...

Page 90

LXT9860/9880 — Advanced 10/100 Repeater with Integrated Management Table 45. Register Map (Continued) Class etherStatsOctets etherStatsPkts etherStatsBroadcastPkts etherStatsMulticastPkts etherStatsCRCAlignErrors etherStatsUndersizePkts etherStatsOversizePkts etherStatsFragments etherStatsJabbers RMON Counters: etherStatsCollisions/ (10 only) rptrMonitorTransmitCollisions etherStatsPkts64Octets etherStatsPkts65to127Octets etherStatsPkts128to255Octets etherStatsPkts256to511Octets etherStatsPkts512to1023Octets etherStatsPkts1024to1518Octets Reserved rptrMonitorTotalOctets(Lower/Upper ...

Page 91

Advanced 10/100 Repeater with Integrated Management — LXT9860/9880 Table 45. Register Map (Continued) Class etherStatsOctets(Lower/Upper) etherStatsPkts etherStatsBroadcastPkts etherStatsMulticastPkts etherStatsCRCAlignErrors etherStatsUndersizePkts etherStatsOversizePkts etherStatsFragments etherStatsJabbers RMON Counters: etherStatsCollisions/ (100 only) rptrMonitorTransmitCollisions etherStatsPkts64Octets etherStatsPkts65to127Octets etherStatsPkts128to255Octets etherStatsPkts256to511Octets etherStatsPkts512to1023Octets etherStatsPkts1024to1518Octets Reserved rptrMonitorTotalOctets(Lower/Upper) rptrAddrTrackNewLastSrcAddress - port ...

Page 92

LXT9860/9880 — Advanced 10/100 Repeater with Integrated Management Table 45. Register Map (Continued) Class Authorized SA port 1 Authorized SA port 2 Authorized SA port 3 Authorized SA port 4 Authorized SA port 5 Authorized Addresses Authorized SA port 6 ...

Page 93

Advanced 10/100 Repeater with Integrated Management — LXT9860/9880 Table 45. Register Map (Continued) Class Auto Negotiate Link Partner Advertisement (port 1) Auto Negotiate Link Partner Advertisement (port 2) Auto Negotiate Link Partner Advertisement (port 3) Auto Negotiate Link Partner Advertisement ...

Page 94

LXT9860/9880 — Advanced 10/100 Repeater with Integrated Management Table 45. Register Map (Continued) Class Auto Negotiate Advertise (ports 1) Auto Negotiate Advertise (ports 2) Auto Negotiate Advertise (ports 3) Auto Negotiate Advertise (ports 4) Auto Negotiate Advertise (ports 5) Auto ...

Page 95

Advanced 10/100 Repeater with Integrated Management — LXT9860/9880 6.2 Counter Registers All counters power up to zero. When reading a 64-bit counter, read the lower address (lower 32 bits of counter) first, followed by the upper address. The first read ...

Page 96

LXT9860/9880 — Advanced 10/100 Repeater with Integrated Management Table 46. Port Counter Registers (Continued) Name rptrMonitorPortFramesTooLong rptrMonitorPortShortEvents rptrMonitorPortRunts rptrMonitorPortCollisions rptrMonitorPortLateEvents rptrMonitorPortVeryLongEvents rptrMonitorPortDataRateMismatches rptrMonitorPortAutoPartitions rptrTrackSourceAddrChanges rptrMonitorPortBroadcastPkts rptrMonitorPortMulticastPkts rptrMonitorPortIsolates rptrMonitorSymbolErrorDuringPacket 1. All offset addresses are expressed in hex. 2. Replace “X” in ...

Page 97

Advanced 10/100 Repeater with Integrated Management — LXT9860/9880 Table 47. RMON Counter Registers - 10 Mbps Name etherStatsOctets etherStatsPkts etherStatsBroadcastPkts etherStatsMulticastPkts etherStatsCRCAlignErrors etherStatsUndersizePkts etherStatsOversizePkts etherStatsFragments etherStatsJabbers etherStatsCollisions/ rptrMonitor Transmit Collisions etherStatsPkts64Octets etherStatsPkts65to127Octets etherStatsPkts128to255Octets etherStatsPkts256to511Octets etherStatsPkts512to1023Octets etherStatsPkts1024to1518Octets Reserved rptrMonitorTotalOctets Datasheet Document ...

Page 98

LXT9860/9880 — Advanced 10/100 Repeater with Integrated Management Table 48. RMON Counter Registers - 100 Mbps Name etherStatsOctets (Lower/Upper) etherStatsPkts etherStatsBroadcastPkts etherStatsMulticastPkts etherStatsCRCAlignErrors etherStatsUndersizePkts etherStatsOversizePkts etherStatsFragments etherStatsJabbers etherStatsCollisions/ rptrMonitor Transmit Collisions etherStatsPkts64Octets etherStatsPkts65to127Octets etherStatsPkts128to255Octets etherStatsPkts256to511Octets etherStatsPkts512to1023Octets etherStatsPkts1024to1518Octets Reserved rptrMonitorTotalOctets (Lower/Upper) ...

Page 99

Advanced 10/100 Repeater with Integrated Management — LXT9860/9880 6.3 Ethernet Address Registers All Ethernet address registers consist of two 32-bit registers that together contain a 48-bit Ethernet address. Address values are unknown on power up. Table 49. Ethernet Address Register ...

Page 100

LXT9860/9880 — Advanced 10/100 Repeater with Integrated Management The Search Address and Search Address Match Registers are described in assignments are provided in Table 51. Search Address/Search Address Match Register Name Search Address Search Match Address Table 52. Search Address ...

Page 101

Advanced 10/100 Repeater with Integrated Management — LXT9860/9880 6.4 Repeater Port Control Registers The Control Register set includes general port control as well as link and learn enable registers. 6.4.1 General Port Control Registers The General Port Control Register bit ...

Page 102

LXT9860/9880 — Advanced 10/100 Repeater with Integrated Management Table 58. Port Link Control Register Name Port Link Control Enable Read only Write only; R/W = Read/Write Latch High Latch Low; SC ...

Page 103

Advanced 10/100 Repeater with Integrated Management — LXT9860/9880 Table 61. Port Status Register Bit Assignments 31:10 9 Port 10 Port 9 Rsvd (MII 2) (MII 1) 1. Not all Status Registers use bits 8 and 9. Table 62. Port Status ...

Page 104

LXT9860/9880 — Advanced 10/100 Repeater with Integrated Management 6.6 PHY Port Status Registers The port auto-negotiation registers are described in Table 65. Auto-Negotiation Registers Auto-Negotiate Link Partner Advertisement #1 (Port 1) Auto-Negotiate Link Partner Advertisement #1 (Port 2) Auto-Negotiate Link ...

Page 105

Advanced 10/100 Repeater with Integrated Management — LXT9860/9880 Table 66. Auto-Negotiate Link Partner Advertisement Bit Definitions (Continued) Bit Name 6 10BASE 10BASE-T 4:0 Selector Field Read only Write only, R/W = Read/Write, LH ...

Page 106

LXT9860/9880 — Advanced 10/100 Repeater with Integrated Management Table 69. PHY Port Status Register Bit Definitions Bit Name 31:16 Reserved 15 100BASE-T4 100BASE-X Full 14 Duplex 100BASE-X Half 13 Duplex 10 Mbps Full 12 Duplex 10 Mbps Half 11 Duplex ...

Page 107

Advanced 10/100 Repeater with Integrated Management — LXT9860/9880 6.7 PHY Port Control Registers Table 70. Auto-Negotiation Advertisement Registers Auto-Negotiate Advertisement #1 (Port 1) Auto-Negotiate Advertisement #1 (Port 2) Auto-Negotiate Advertisement #1 (Port 3) Auto-Negotiate Advertisement #1 (Port 4) Auto-Negotiate Advertisement ...

Page 108

... Part ID Number. The next 11 bits R 13C contain a JEDEC Manufacturer ID, which for Intel is hexadecimal ‘FE’. The lowest bit (0) is set only for the first device in a chain. The encoding scheme used for the Product ID field is implementation dependent. ...

Page 109

Advanced 10/100 Repeater with Integrated Management — LXT9860/9880 Table 74. Configuration Registers (Continued) Name Global LED Control Register Port LED Control Register LED Timer Control Register Repeater Reset Register Software Reset Register Assign Address Register (1 and 2) PROM Address ...

Page 110

LXT9860/9880 — Advanced 10/100 Repeater with Integrated Management Table 75. Repeater Configuration Register (Continued) Bit Name Enable Port 12 Late Event 11 Register Clear 10 Statistics Enable Statistics Enable-Turns statistics gathering on and off. 9 Send /T/R 8 Isolate100 7 ...

Page 111

... The JEDEC 8-bit identifier. However, the MSB is for parity only and is ignored. Intel’s JEDEC (1111 1110) which becomes 111 1110. 2. First Chain Bit = 0 if ChipID First Chain Bit = 1 if ChipID = 00. 6.8.2 ...

Page 112

LXT9860/9880 — Advanced 10/100 Repeater with Integrated Management Table 80. LED Configuration Bit Name 31:20 Reserved 19:18 MII2LED 17:16 MII1LED 15:14 PortLED7 13:12 PortLED6 11:10 PortLED5 9:8 PortLED4 7:6 PortLED3 5:4 PortLED2 3:2 PortLED1 1:0 PortLED0 Read ...

Page 113

Advanced 10/100 Repeater with Integrated Management — LXT9860/9880 6.8.6 Repeater Reset Register Table 83. Repeater Reset Bit Name 31:1 Reserved Reserved. RPTRRS Writing a ‘1’ to this bit causes the repeater logic to be reset. Counter 0 T and configuration ...

Page 114

LXT9860/9880 — Advanced 10/100 Repeater with Integrated Management Table 86. Interrupt Status Register Bit Definitions Bit Name 31:6 Reserved 5 JABINT 4 ISOLINT 3 PARTINT 2 FCCINT 1 SACHNGINT 0 SPDCHNGINT Read only Write only, ...

Page 115

Advanced 10/100 Repeater with Integrated Management — LXT9860/9880 Table 87. Interrupt Mask Bit Definitions Bit Name 31:6 Reserved 5 JABMSK 4 ISOLMSK 3 PARTMSK 2 FCCMSK 1 SACHNGMSK 0 SPDCHNGMSK Read only Write only, R/W ...

Page 116

LXT9860/9880 — Advanced 10/100 Repeater with Integrated Management Table 90. Assign Addr 2 Bit Name 31.21 Reserved 20:16 Hub ID 15:0 ASSIGN150 Read only Write only, R/W = Read/Write Latch High ...

Page 117

Advanced 10/100 Repeater with Integrated Management — LXT9860/9880 7.0 Mechanical Specifications Figure 42. LXT98x0 Package Specifications for Commercial Temperature 208-Pin Plastic Quad Flat Package • Part Number LXT98x0HC, LXT98x0AHC • Commercial Temperature Range ( ...

Page 118

LXT9860/9880 — Advanced 10/100 Repeater with Integrated Management Figure 43. LXT98x0 Package Specifications for Extended Temperature 208-Pin Plastic Quad Flat Package Heat Slug • Part Number LXT9880AGE • Extended Temperature Range (- +85 C) 118 Datasheet Document #: ...