PKV3313PI Ericsson Power Modules, PKV3313PI Datasheet - Page 19

DC/DC Converters & Regulators 12 Vdc 0.25 Iso Input 9-36V 3W

PKV3313PI

Manufacturer Part Number
PKV3313PI
Description
DC/DC Converters & Regulators 12 Vdc 0.25 Iso Input 9-36V 3W
Manufacturer
Ericsson Power Modules
Series
PKVr
Datasheets

Specifications of PKV3313PI

Product
Isolated
Output Power
3 W
Input Voltage Range
9 V to 36 V
Number Of Outputs
1
Output Voltage (channel 1)
12 V
Output Current (channel 1)
0.25 A
Isolation Voltage
1.5 KV
Output Type
Isolated
Lead Free Status / Rohs Status
 Details

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PKV3313PI
Manufacturer:
FLOETH
Quantity:
12 000
Delivery Package Information
The PKV series DC/DC converters are delivered in tubes with
a lenght of 384 mm (15.1 in)
Tube Specifi cation
Material:
Max surface resistance:
Color:
Capacity:
Weight:
End stops
EN/LZT 146 37 R2D © Ericsson Power Modules AB, September 2004
Miscellaneous
Soldering Information
The PKV Series DC/DC converters are intended for through
hole mounting on a PCB. When wave soldering is used max
temperature on the pins are specified to 230°C for 10 seconds.
Maximum preheat rate of 2°C/s is suggested. When hand
soldering is used a thermocouple needs to be mounted on the
DC/DC converter pins to verify that pin temperatures does not
exceed 300°C for longer time than 10 seconds with the used
soldering tools.
No-clean flux is recommended to avoid entrapment of cleaning
fluids in cavities inside of the DC/DC power module. The
residues may affect long time reliability and isolation voltage.
PVC
10 to1000 MOhm/sq
Transparent
10 pcs/tube
typ 160 g
Pins
Test set up
Quality
Reliability
According to MIL-HDBK-217F the calculated MTBF
value at 100% load (from PKV 5211 PI) at the following
ambient temperatures will be approx.:
T
10 °C
25 °C
40 °C
60 °C
75 °C
At 80–100% load the case temperature will be approx.
15–20 °C higher than the ambient temperature.
Quality Statement
The PKV series DC/DC converters are designed and
manu factured in an in dus tri al en vi ron ment where
quality systems and methods like ISO 9000 and SPC are
in ten sive ly in use to boost the continuous im prove ments
strategy. Infant mor tal i ty or early fail ures in the products
are screened out by a burn-in pro ce dure.
Warranty
Ericsson Power Modules war rants to the original pur chas er
or end user that the product con form to this Data Sheet
and are free from ma te ri al and work man ship defects for
a period of fi ve (5) years from the date of man u fac ture, if
the prod uct is used within specifi ed con di tions and not
opened. In case the prod uct is dis con tin ued, claims will
be ac cept ed up to three (3) years from the date of the
discontinuation. For additional details on this limited
warranty we refer to Ericsson Power Modules “Gen er al
Terms and Con di tions of Sales”, or in di vid u al con tract
documents.
Limitation of liability
Ericsson Power Modules does not make any other
warranties, ex pressed or implied including any war ran ty
of merchant ability or fi t ness for a par tic u lar pur pose
(including, but not lim it ed to, use in life support
applications, where mal func tions of product can cause
injury to a person’s health or life).
0 °C
amb
Hours
2.7 million
1.5 million
650 000
276 000
88 000
37 000
19