V640-HAM11-V2 Omron, V640-HAM11-V2 Datasheet

no-image

V640-HAM11-V2

Manufacturer Part Number
V640-HAM11-V2
Description
RFID CONTROLLER AMPLIFIER
Manufacturer
Omron
Datasheet

Specifications of V640-HAM11-V2

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
V640HAM11V2
Enables reading and writing
transponders for various Semiconductor
applications, such as FOUPs (Front-
Opening Unified Pods), reticles, and
pods.
• Conforms to Carrier Reader/Writer-related SEMI stan-
• Antenna dimensions conform to SEMI E15.1.
• Reads/writes data embedded in a 32-mm Glass Multipage
• Noise measurement function for detecting proper place-
• Shielded antenna reduces influence of surrounding metal.
• Lineup incudes compact models designed for long-range
• CE marking/FCC approvals
System Configuration
■ Standard Models
dards; SEMI E99, E4, and E5.
Transponder (RI-TRP-DR2B/-WR2B).
ment of Antenna.
communications.
Electromagnetic Inductive RFID System
V640 for Semiconductor Industry
RI-TRP-DR2B
RI-TRP-WR2B
(32-mm Glass
Transponder)
Texas
Instruments
ID Tag
Electromagnetic Inductive RFID System
CIDRW Head
V640-HS61
Amplifier Unit
V640-HAM11-V2
V640 for Semiconductor Industry
CIDRW Controller
V700-L22
RS-232C host device
via ASCII protocol
RS-232C host device
via SECS I/II protocol
RS-232C host device
via dedicated 1:1
protocol
RS-485 host device
via ASCII protocol
1

Related parts for V640-HAM11-V2

V640-HAM11-V2 Summary of contents

Page 1

... RI-TRP-WR2B (32-mm Glass Transponder) Texas Instruments V640-HS61 Electromagnetic Inductive RFID System Amplifier Unit CIDRW Controller V640-HAM11-V2 V700-L22 V640 for Semiconductor Industry RS-232C host device via dedicated 1:1 protocol RS-232C host device via ASCII protocol RS-232C host device via SECS I/II protocol ...

Page 2

... Note: 1. Use of the V700-L11 ID Link Unit enables the Amplifier Unit to be removed/installed while the CIDRW System remains turned ON in the event of a malfunction or during maintenance. 2. Use the V700-L22 CIDRW Controller when using SECS communications protocol. 3. Refer to the User’s Manual (V640-HAM11-V2: Cat. No. Z167; V640-HAM12: Cat. No. Z218) for details. 2 Electromagnetic Inductive RFID System ...

Page 3

... Ordering Information ■ List of Models Name CIDRW Head V640-HS61 V600-HS62 Amplifier Unit V640-HAM11-V2 V640-HAM12 CIDRW Controller V700-L22 ID Link Unit V700-L11 Accessories V640-A90 Note: V640-A90 includes all of these accessories as a set. To purchase individual accessories, contact the manufacturers below directly. To Purchase Individual Accessories ...

Page 4

... Approx. 500 g 4 Electromagnetic Inductive RFID System V640-HS61 2 2 acceleration for 3 times each and Z directions (18 times in total) V640-HAM11- acceleration for 3 times each and Z directions (18 times in total) V640 for Semiconductor Industry V640-HS62 acceleration with 10 sweeps of 8 min each and 1.9-m (3-mm dia.) coaxial cable Approx ...

Page 5

... Electromagnetic Inductive RFID System V700-L22 2 2 acceleration for 3 times each and Z directions (18 times in total) V700-L11 2 2 acceleration for 3 times each and Z directions (18 times in total) V640 for Semiconductor Industry acceleration with 10 sweeps of 8 min each and acceleration with 10 sweeps of 8 min each and 5 ...

Page 6

... Note: SEMI: Semiconductor Equipment and Materials International (Refer to SEMI for standards information. (SEMI URL: http//:www.semi.org/)) SECS: SEMI Equipment Communications Standard Refer to the User’s Manual (V640-HAM11-V2: Cat. No. Z167; V640-HAM12: Cat. No. Z218) for details. V700-L22 conforms to SEMI E99-0303 (issued in March 2003). ...

Page 7

... Dimensions Note: All units are in millimeters unless otherwise indicated. Amplifier Unit V640-HAM11-V2 (30.5) (15.8) (13) (32.5) Four operation indicator lamps (30.5) V640-HAM12 (15.8) (13) (32.5) Electromagnetic Inductive RFID System 185 160 6.8 6.8 (17.8) 6.8 0.6 (12) 55.5 175 (4.5) (1.5) Mounting Hole Dimensions 175± ...

Page 8

... Four, 4.5 dia. (mounting holes) 30 110 110 41.5 41.5 26.5 41.3 20.3 18.5 5 Two, 4.5 dia. 4 V640 for Semiconductor Industry Connector Mounting Hole Dimensions Antenna center 4-M3 or 3.5 dia. 9 21±0.2 Connector Mounting Hole Dimensions 4-M3 or 3.5 dia. 20±0.2 9 21±0.2 14 ...

Page 9

... Cancellation; Etc. Orders are not subject to rescheduling or cancellation unless Buyer indemnifies Omron against all related costs or expenses. 10. Force Majeure. Omron shall not be liable for any delay or failure in delivery resulting from causes beyond its control, including earthquakes, fires, floods, strikes or other labor disputes, shortage of labor or materials, accidents to machinery, acts of sabotage, riots, delay in or lack of transportation or the requirements of any government authority ...

Page 10

... São Paulo, SP, Brasil • 55.11.2101.6300 • www.omron.com.br OMRON ELECTRONICS MEXICO • HEAD OFFICE Apodaca, N.L. • 52.811.156.99.10 • 001.800.556.6766 • mela@omron.com OMRON EUROpE B.V. Wegalaan 67-69, NL-2132 JD, Hoofddorp, The Netherlands. Tel: +31 (0) 23 568 13 00 Fax: +31 (0) 23 568 13 88 www.industrial.omron.eu Z191-E1-04 09/06 OMRON ARGENTINA • ...

Related keywords