GP1UD272XK Sharp Microelectronics, GP1UD272XK Datasheet - Page 6

RECEIVER REMOTE CTRL TOP 36.7KHZ

GP1UD272XK

Manufacturer Part Number
GP1UD272XK
Description
RECEIVER REMOTE CTRL TOP 36.7KHZ
Manufacturer
Sharp Microelectronics
Datasheet

Specifications of GP1UD272XK

Sensing Distance
10m
B.p.f. Center Frequency
36.7kHz
Voltage - Supply
2.7 V ~ 5.5 V
Current - Supply
200µA
Orientation
Top View
Mounting Type
Through Hole
Lead Free Status / Rohs Status
Contains lead / RoHS non-compliant
Other names
425-1121
1. When this infrared remote control detecting unit shall be adopted for wireless remote control, please use it with the signal format of
2. Use the light emitting unit (remote control transmitter), in consideration of performance, characteristics, operating conditions of
3. Pay attention to a malfunction of the light detecting unit when the surface is stained with dust and refuse.
4. The shield case should be grounded on PCB pattern.
5. Do not apply unnecessary force to the terminal and the case.
6. Do not push the light detector surface (photodiode) from outside.
7. To avoid the electrostatic breakdown of IC, handle the unit under the condition of grounding with human body, soldering iron, etc.
8. Do not use hole and groove set in the case of the light detecting unit for other purposes, since they are required to maintain the
9. External Circuit Examples (Mount the outer parts as near the unit as possible).
10. There is a possibility that noise on output may be caused by environmental condition (Disturbing light noise, Electromagnetic
11. Please shall confirm operation or your actual machine. Because the output pulse width of this product is fluctuated by
transmitter, which total duty ratio D
(Pulse width of the presence of modulated IR) should be 250 s or more. In case that the signal format of total duty and ON signal
time is out of above conditions, there is a case that reception distance is much reduced or output is not appeared.
light emitting device and the characteristics of the light detecting unit.
Care must be taken not to touch the light detector surface.
If it should be dirty, wipe off such dust and refuse with soft cloth so as to prevent scratch. In case some solvents are required, use
methyl alcohol, ethyl alcohol or isopropyl alcohol only.
Also, protect the light detecting unit against flux and others, since their deposition on the unit inside causes reduction of the
function, fading of markings such as the part number.
(The area across the shield case and the GND terminal is internally conductive in some cases and non-conductive in some other
cases.)
specified performance.
In setting R
Precautions for Operation
noise, Power supply line noise, etc.) even if there is no input transmission signal.
environmental conditions such as signal format, temperature, distance from transmitter, and so on.
1
and C
t
1
1
, use suitable values after considering under the real condition
t
2
GND
V
V
GP1UD26XK Series/GP1UD27XK Series/GP1UD28XK Series/GP1UD28YK Series
t
CC
OUT
(Emitting time
Transmitting time for 1 block:T
t
3
D
t
=(
C
N 1
n
O
t
N
/ T) 100 (%)
N 1
n
t
N
/ Transmitting time for 1 block T) is 40% or less. ON signal time T
R
1
GND
V
V
e
O
T
t
ON
(Circuit parameters)
R
C
n
1
1
47
47 F
5%
ON

Related parts for GP1UD272XK